1 / 96

Panasonic Communications Co., Ltd.

KX-NCP0158 (8ch DECT IP-CS) Technical information (Edition-1). Panasonic Communications Co., Ltd. “. IP-CS Concept - 1. 8ch IP DECT Cell Station. - Designed to extend system feature to DECT handsets - Wireless solution for remote office communication.

jada-daniel
Download Presentation

Panasonic Communications Co., Ltd.

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. KX-NCP0158 (8ch DECT IP-CS) Technical information (Edition-1) Panasonic Communications Co., Ltd.

  2. IP-CS Concept - 1 8ch IP DECT Cell Station • - Designed to extend system feature to DECT handsets • - Wireless solution for remote office communication. • - Provides 8 call user connections over 10/100Mbit LAN • - No special cabling required (overcomes distance issue) • - Powered by POE remotely • - Simplifies installation for TDE & NCP • - No Activation Key requirements. • - One DSP (DSP-4, -16, -64) card is needed. • - Compatible with “Legacy” CS’ TDA0141/TDA042and TDA0158.

  3. IP-CS Concept - 2 Remote office-1 • Seamless Hand over between TDA0141/0142/0158 and IP-CS • - Roaming KX-NCP MPR 2.0 KX-TDE MPR 3.0 DSP (4/16/64) is needed. LAN Network Local office Remote office-2 Seamless Hand over Roaming Ext.100 Ext.100

  4. Contents - Introduction - System Capacity - VoIP Channel Capacity - Hand over - Air Synchronization - Installation

  5. Introduction -1 Specifications

  6. System Capacity

  7. System Capacity -1 The KX-NCP0158 connects other device via DSP voice channels (Need DSP resources). The KX-NCP0158 is installed into Virtual Slot. One Slot supports 4 x KX-NCP0158.

  8. System Capacity -2 Sample: NCP500 One Slot supports 4 x KX-NCP0158. Room A Room B Remote-A Remote-B Remote-C Remote-D Remote-E Remote-F

  9. VoIP Channel Capacity

  10. VoIP Channel Capacity - 1 DSP Resource KX-DT3xx IP-Trunk DSP IP-Trunk Traditional IP-CS KX-NCP0158 IP-Ext. KX-NTxx The IP-CS does not support Peer to Peer connection mode. →Need DSP resource

  11. VoIP Channel Capacity - 2 DSP Resource (Cont.) Need DSP resource KX-DT3xx IP-Trunk DSP IP-Trunk Traditional IP-CS KX-NCP0158 IP-CS KX-NCP0158 The IP-CS does not support Peer to Peer connection mode.

  12. VoIP Channel Capacity - 3 DSP Resource (Cont.) Need DSP resource KX-DT3xx IP-Trunk DSP IP-Trunk Traditional IP-CS KX-NCP0158 The IP-CS does not support internal connection mode.

  13. VoIP Channel Capacity - 4 DSP Resource (Cont.) DSP Power

  14. VoIP Channel Capacity - 5 The number of simultaneous telephone calls through IP-CS. (Sample : NCP500/1000 MPR 2.0) [Restriction Key]

  15. VoIP Channel Capacity - 6 The number of simultaneous telephone calls through IP-CS. (Sample : NCP500/1000 MPR 2.0) [Restriction Key]

  16. Handover

  17. Handover - 1 Present Path Handover (Start) KX-DT3xx IP-Trunk DSP IP-Trunk Traditional IP-CS-1 KX-NCP0158 IP-CS-2 KX-NCP0158 Handover CS-1 to CS-2.

  18. Handover - 2 Present Path Handover (During Hand over) Handover Path KX-DT3xx IP-Trunk DSP IP-Trunk Traditional 1- Keep hand over DSP resource 2- Synchronize packet CS-1 and CS-2 IP-CS-1 KX-NCP0158 IP-CS-2 KX-NCP0158 Require DSP spare resource Connect Both CS during handover.

  19. Handover - 3 Handover (Cut over) New Path KX-DT3xx IP-Trunk DSP IP-Trunk Traditional 1- Cut over 2- Release hand over DSP resource IP-CS-1 KX-NCP0158 IP-CS-2 KX-NCP0158

  20. Handover - 4 Present Path Handover (If No-DSP resource) KX-DT3xx IP-Trunk DSP IP-Trunk Requests DSP resource Traditional If there is no hand over DSP resource IP-CS-1 KX-NCP0158 IP-CS-2 KX-NCP0158 Hand over does not perform. There is no major/minor error information. Connect Both CS during handover.

  21. Handover - 5 ASCII Command Log data, If DSP resource is not enough. ASCII Command : “PSDSP” may help investigation. MPR>PSDSP Last Num : 80 ← The newest log starting log number. No. Time Extno Logno Slot/Port Cause [001] 07/09/20 11:37:00 00402 21000007 08/00 01/03 [002] 07/09/21 11:37:00 00402 21000005 00/03 02/04 [128] 07/09/21 11:37:00 00402 21000005 00/03 02/04 1 2 3 4 5 6 1. Log number. 2. Logged Time 3. PS Extension number 4. PS internal data 5. Connected IPCS slot/port 6. Cause of log.

  22. Air Synchronization (Basic technology)

  23. Air Synchronization (Basic technology) - 1 Please understand the technology of DECT. Otherwise, we cannot understand the technology of Air Synchronization. The DECT signal consists of a transmitting frame (TX) and a receiving frame RX). And the composition of each frame (TX/RX) is as follows. Time Slot Frequency US-DECT is not supported Time decomposition “Time Division Multiplex” TX/RX Sequence Frequency Euro: f0-f9 US: f0-f4 TX TX RX RX

  24. Air Synchronization (Basic technology) - 2 One CS is connecting 1 x DECT-PS The one communication DECT signal consists of two control channels (D) and one voice channel (V). Sample (Control channel always uses even number frames. ) TS3 TS3 TX TX TS0 (D) , TS2 (D), TS3 (V)

  25. Air Synchronization (Basic technology) - 3 One CS is connecting 2 x DECT-PS If a CS is connecting 2 x DECT-PS, data channels and voice channel consist as follows, Sample The data channels (D) is the common data for both DECT-PS. The voice data is separated by the time slots. E.g. TS-3 and TS-4 TS3 TS3 TX TX No collision TS4 TS4

  26. Air Synchronization (Basic technology) - 4 One CS is connecting 8 x DECT-PS If a CS is connecting 8 x DECT-PS, data channels and voice channel consist as follows, Sample

  27. Air Synchronization (Basic technology) - 5 Super frame synchronization (Wired Connection) Internal Clock PRI/BRI The same DECT Sync-Clock on the cable-1 and the cable-2. System Clock Sync-Clock Sync-Clock DECT Sync-Clock Cable-1 Cable-2 CS-1 signal CS-2 signal are synchronized. PLL PLL Super frame synchronization CS-1 CS-2 Seamless handover is possible.

  28. Air Synchronization (Basic technology) - 6 Super frame synchronization (Wired Connection) When two or more CS are installed closely together, all the CS use different control channels. Sample D-1 D-2 CS-1 CS-2 DECT-PS can find CS by receiving D-Channel. Unless both CS-1 and CS-2 have synchronization, the DECT-PS cannot find any CS other than the CS it is already connected to.

  29. Air Synchronization (Basic technology) - 7 Super frame synchronization (Wired Connection) When two or more sets of CS are installed in closely, all the CS uses different control channels. Sample D-1, V-1 D-2, V-2 CS-1 CS-2 During handover (CS-1 to CS-2) the DECT-PS is communicating to two CSs.

  30. Air Synchronization (IP-CS)

  31. Air Synchronization (IP-CS) - 1 Super frame synchronization (WirelessConnection) Internal Clock PRI/BRI No- Sync-Clock System Clock DSP Sync-Clock Sync-Clock DECT Sync-Clock Cable-1 How to synchronize ? PLL PLL CS-2 KX-NCP0158 CS-1

  32. Air Synchronization (IP-CS) - 2 Super frame synchronization (WirelessConnection) Internal Clock PRI/BRI System Clock DSP Sync-Clock DECT Sync-Clock Slave-CS Cable-1 D-1 D-2 PLL PLL PLL Master-CS IC-CS picks up D channel signal from other CS CS-2 KX-NCP0158 CS-1 Air Synchronization

  33. Air Synchronization (IP-CS) - 3 Super frame synchronization (WirelessConnection) DSP Master-CS Slave-CS D-1 D-2 PLL Internal Clock IC-CS picks up D channel signal from other CS CS-1 KX-NCP0158 CS-2 KX-NCP0158

  34. Air Synchronization (IP-CS) - 4 Legacy CS (KX-TDA0141/TDA042/TDA0158) A Legacy CS will receive its timing and synchronisation from the PBX, therefore TDA0141/TDA0142 and TDA0158 must be CS-Master. IP-CS (Mater) An IP-CS configured as CS-Master will create and send out its own timing and synchronisation. IP-CS (Slave) An IP-CS configured as CS-Slave will receive timing and synchronisation from either a legacy CS or IP-CS set to CS-Master

  35. Air Synchronization (IP-CS) - 5 Super frame synchronization (WirelessConnection) Master Slave Slave Slave DSP Level Level-1 Level-2 Level-3,4 Level-5 Max.5 Levels Seamless handover Area Master Slave Slave Slave Internal Clock DSP Level Level-1 Level-2 Level-3,4 Level-5 Max.5 Levels

  36. Air Synchronization (IP-CS) - 6 Super frame synchronization (WirelessConnection) Master Slave Master Slave Internal Clock DSP Level Level-1 Level-2 Level-1 Level-2 Handover is not possible between a Legacy CS-Master and an IP-CS Master Seamless handover Area Master Slave Master Slave Internal Clock Internal Clock DSP Level Level-1 Level-2 Level-1 Level-2 Handover is not possible between an IP-CSMaster and an IP-CS Master

  37. Air Synchronization (IP-CS) - 7 Super frame synchronization (WirelessConnection) Synchronization Seamless handover Area Local office Remote office CS-2 CS-6 CS-1 CS-5 Internal Clock CS-3 CS-7 DSP CS-4 CS-8 Handover Sample: CS-2 ↔ CS-3 CS-3 ↔ CS-4 CS-2 ↔ CS-4 Handover Sample: CS-6 ↔ CS-7 CS-7 ↔ CS-8 CS-6 ↔ CS-8

  38. Air Synchronization (IP-CS) - 8 Super frame synchronization (WirelessConnection) Synchronization Seamless handover Area CS-3 CS-1 CS-4 DSP CS-2 CS-5 Handover Sample: CS-1 ↔ CS-5 CS-2 ↔ CS-3 CS-3/4 ↔ CS-5

  39. Air Synchronization (IP-CS) - 9 Super frame synchronization (WirelessConnection) Synchronization Seamless handover Area Slave Slave Master Internal Clock Slave Slave DSP Slave Slave

  40. Air Synchronization (Programming)

  41. Air Synchronization (Programming) - 1 Programming parameters.

  42. Air Synchronization (Programming) - 2 CS Class Sync Master CS1 : Select Internal clock. Sync Master CS2 : Should Connect S-Master CS1 Sync Slave CS : Connect S-Master CS1 or S-Master CS 2 or S-Slave CS CS Link Destination Physical CS is fixed to S-Master CS1. Slot Type Virtual : IP-CS Physical : Wire Connection CS. Connection INS : CS Class can not change. OUS : CS Class can change.

  43. Air Synchronization (CS-Class)

  44. Air Synchronization (CS Class) - 1 Sync Master CS 1 CS Class Sync Master CS1 : Select Internal clock. Sync Master CS2 : Should Connect S-Master CS1 Sync Slave CS : Connect S-Master CS1 or S-Master CS 2 or S-Slave CS Local office Remote office S-S CS S-S CS S-M CS-1 S-M CS-1 Internal Clock S-S CS S-S CS DSP Physical CS is fixed to S-Master CS1. S-S CS S-S CS Seamless handover Area

  45. Air Synchronization (CS Class) - 2 Sync Master CS 1 CS Class Sync Master CS1 : Select Internal clock. Sync Master CS2 : Should Connect S-Master CS1 Sync Slave CS : Connect S-Master CS1 or S-Master CS 2 or S-Slave CS Local office Remote office S-S CS S-S CS S-M CS-1 S-M CS-1 Internal Clock Internal Clock S-S CS S-S CS DSP S-S CS S-S CS Seamless handover Area

  46. Air Synchronization (CS Class) - 3 Sync Master CS 2 CS Class Sync Master CS1 : Select Internal clock. Sync Master CS2 : Should Connect S-Master CS1 Sync Slave CS : Connect S-Master CS1 or S-Master CS 2 or S-Slave CS S-S CS S-S CS Stop S-M CS-1 S-M CS-1 Stop Internal Clock Stop S-S CS S-S CS DSP DSP Stop S-S CS S-S CS Disconnect Arrive check If the S-M CS-1 network connection is lost ➔ all Slave CS stop.

  47. S-S CS Stop S-M CS-1 Stop Stop S-S CS DSP Stop S-S CS Disconnect “ Air Synchronization (CS Class) - 4 Sync Master CS 2 CS Class Sync Master CS1 : Select Internal clock. Sync Master CS2 : Should Connect S-Master CS1 Sync Slave CS : Connect S-Master CS1 or S-Master CS 2 or S-Slave CS How to improve ? S-S CS S-M CS-1 Internal Clock S-S CS DSP S-M CS-2 Assign one CS as “Sync Master CS2.”

  48. Air Synchronization (CS Class) - 5 Sync Master CS 2 CS Class Sync Master CS1 : Select Internal clock. Sync Master CS2 : Should Connect S-Master CS1 Sync Slave CS : Connect S-Master CS1 or S-Master CS 2 or S-Slave CS How to Work Step-1 Step-2 S-S CS S-S CS S-S CS S-S CS Internal Clock Stop Internal Clock DSP DSP Master S-M CS-2 S-M CS-1 Disconnect Disconnect Arrive check The S-M CS-2 is going to be the Master

  49. Air Synchronization (CS Class) - 6 Sync Master CS 2 CS Class Sync Master CS1 : Select Internal clock. Sync Master CS2 : Should Connect S-Master CS1 Sync Slave CS : Connect S-Master CS1 or S-Master CS 2 or S-Slave CS Step-3 Step-4 S-S CS S-S CS S-S CS S-S CS Internal Clock Internal Clock DSP DSP Master Synchronize with S-M CS-2 Re-cover Arrive check

  50. Air Synchronization (CS Class) - 7 Sync Master CS 2 CS Class Sync Master CS1 : Select Internal clock. Sync Master CS2 : Should Connect S-Master CS1 Sync Slave CS : Connect S-Master CS1 or S-Master CS 2 or S-Slave CS Step-4 Step-6 S-S CS S-S CS S-S CS S-S CS Internal Clock Internal Clock DSP DSP Synchronize information S-M CS-2 Finish Recovery

More Related