120 likes | 264 Views
Homogeneity of Small Chambers T4, T6, T7, T8 and Gas Gain Measurements of Frascati and Roma Chambers . Emmanuel Angulo (CSU Fresno) Weekly Meeting ATLAS Muon Micromegas 7/8/2012. Cu X-Ray Measurements. 9 0 Positions (0.9cm x 1 cm ) HV of Strips @ 52 0 HV of Drift @ 300
E N D
Homogeneity of Small Chambers T4, T6, T7, T8 and Gas Gain Measurements of Frascati and Roma Chambers Emmanuel Angulo (CSU Fresno) Weekly Meeting ATLAS MuonMicromegas 7/8/2012
Cu X-Ray Measurements • 90 Positions (0.9cm x 1cm) • HV of Strips @ 520 • HV of Drift @ 300 • X-Ray with 1mm collimator and cu foil cover @ 100000 event count, and @ 10mm distance from chamber
T6 Uniformity Connector 2 Connector 2 Connector 1 Connector 2 Middle point 6cm x 5cm Corner points 1cm x 1cm Connector 2 Connector 1
T7 Uniformity Connector 2 Connector 1 Connector 1 Middle point 4cm x 5cm Corner points 1cm x 1cm Connector 2 Connector 1
T8 Uniformity Connector 2 Connector 1 Connector 1 Middle point 4cm x 5cm Noise up to Ch 143 (Bad signal with connector 2) Corner points 1cm x 1cm Connector 2 Connector 1
T8 Uniformity with 55Fe • 25 Positions (1.8cm x 1.8cm) • 3mm Collimator Hole @ 50000 event count • Strip HV @ 520 • Drift HV @ 300
Roma and Frascati Chambers Gas Gain 55Fe Measurements X-Strips 1 2 • 5 Positions (1.8cm x 1.8cm) • 3mm Collimator Hole @ 20000 event count • Strip HV from 440-560 • Drift HV @ 300 Y-Strips 3 4 5 HV Connectors