Carbon Monoxide Alarms

Carbon Monoxide Alarms. Statutory Guidance. The Repairing Standard.

janicegray
Download Presentation

Carbon Monoxide Alarms

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Carbon Monoxide Alarms Statutory Guidance

  2. The Repairing Standard (6) In determining whether a house meets the standard of repair mentioned in subsection (1)(g), regard is to be had to any building regulations and any guidance issued by the Scottish Ministers on provision for giving warning if carbon monoxide is present in a concentration that is hazardous to health.

  3. Carbon monoxide • Carbon monoxide (CO) is an invisible, tasteless and odourless gas produced by the incomplete combustion of a fuel, for example when gas, oil, coal or wood do not burn properly. • In the home this is most commonly caused by appliances and flues that have been incorrectly installed, not maintained or are poorly ventilated. • Symptoms of concentration of CO – headache, fatigue, dizziness, nausea, convulsions, unconsciousness, death

  4. Carbon Monoxide Alarms From 1 October 2013, the Scottish building regulations require carbon monoxide alarms to be fitted when a new or replacement boiler or other heating appliance is to be installed in a dwelling and other buildings with bedrooms. The new requirement for carbon monoxide detectors in private rented houses comes into effect on the 1st December 2015

  5. Carbon Monoxide Alarms Statutory Guidance Private landlords must ensure that a detection system is installed in all dwellings they rent to tenants where there is: • a fixed combustion appliance (excluding an appliance used solely for cooking) in the dwelling or • a fixed combustion appliance in an inter-connected space, for example, an integral garage • a combustion appliance necessarily located in a bathroom ( advice would be to locate it elsewhere ) - the CO detector should be sited outside the room as close to the appliance as possible but allowing for the effect humid air might have on the detector when the bathroom door is open.

  6. Carbon Monoxide Alarms Statutory Guidance A CO detection system is not required in an attached out-building or garage where there is no inter-connection with the house e.g. a door. To be clear, if there is no way that CO could reasonably be expected to find a path into the house there is no need for a detector. However, a detection system IS required if the combustion appliance ( primarily boilers ) is located in an attic.

  7. Carbon Monoxide Alarms Statutory Guidance A CO detection system to alert occupants to the presence of CO gas should consist of at least: 1 CO detector in every space containing a fixed combustion appliance (excluding an appliance used solely for cooking) and 1 CO detector to provide early warning in high risk accommodation, that is, a bedroom or principal habitable room, where a flue passes through these rooms.

  8. Carbon Monoxide Alarms

  9. Carbon Monoxide Alarms Statutory Guidance Check guidance for details on positioning of detector and places where a CO detector should not be sited CO detectors in the space containing the combustion appliance should be sited between 1 and 3 metres from the appliance. Unless otherwise indicated by the manufacturer, CO detectors should be either - • Ceiling mounted and positioned at least 300 mm from any wall or • Wall mounted and positioned at least 150 mm below the ceiling and higher than any door or window in the room.

  10. Carbon Monoxide Alarms Statutory Guidance Other standards may apply, for example regarding HMOs Detection of carbon monoxide is covered in section 4.5 of the Scottish Government guidance for local authorities on licensing of HMOs

  11. Carbon Monoxide Alarms Statutory Guidance It is expected that landlords will have regard to this guidance immediately and ensure CO detection is installed by 1st December 2015.  However, if a landlord has a scheduled annual gas safety check it is reasonable to arrange work to install CO detectors at the same time. This will mean that no more than one year from the date of this guidance (23rd June 2015), all private rented properties should have adequate CO detectors installed.

  12. Statutory Guidance