Problems Related to the Useof Climate Control Systems • Accumulation and propagation of living microbes and viruses in climate control systems under service conditions • Lack of normative base and practical experience in using efficient devices for air decontamination in Climate control systems especially on the passenger railway and air transport, in public places, etc. • Increase and spread of HAI Besides up-to-date technical means, the provision of biologically safe operation of climate control systems in public facilities and transport needs a normative base, a set of standards and a system of approaches aimed at prevention and localization of epidemics and pandemics Scientific-manufacturing firm "Potok Inter" Moscow, Khavskayast 18,Building 2, tel/fax +7(499)678-20-99, www.potok-inter.ru, e-mail: post@potok-inter.ru
Approaches to the Promotion of Biological Safety Individual Means of Protection: • Vaccination it will take several months to produce the necessary amount of vaccine at the upriseof a pandemic infection; • Diagnostics; • Etc. Anti-epidemic Measures: • Quarantine it will not have any significant influence on prevention and propagation of pandemia apart from slowing down its spread for a few days at best; • Technical means of protection including those, which provide safe use of climate control systems • Etc. Scientific-manufacturing firm "Potok Inter" Moscow, Khavskayast 18,Building 2, tel/fax +7(499)678-20-99, www.potok-inter.ru, e-mail: post@potok-inter.ru
Technical Means for Air Decontamination Biological safety of climate control systems can be achieved through using highly efficient, harmless for man, easy-to-run-and-maintain devices, which provide inactivation of microbes and viruses. • UV irradiation inactivates surface microbes and viruses. • This method has a lot of limitations when used for air disinfection. • Highly efficient (HEPA) filters provide fine aerosols filtration (from 0.2mcm). • They cannot be used to inactivate microbes and viruses. • “POTOK” technology inactivate microbes and viruses as well as provide fine aerosols filtration (from 0.01 mcm). Scientific-manufacturing firm "Potok Inter" Moscow, Khavskayast 18,Building 2, tel/fax +7(499)678-20-99, www.potok-inter.ru, e-mail: post@potok-inter.ru
“Potok” Technology Infected air Decontamination of airflow is carried out in two stages: • at the first stage, the air gets into the zone, where microbes are exposed to repeated combined exposure of electrostatic fields with radically different voltage values and gradients and of differently charged ions. Their combined action causes irreversible damage or complete destruction of the microbial cells; • at the second stage, the airflow passes on to the zone of filtration, where an electrostatic precipitator intercepts fragments of the destroyed microbial cells and airborne aerosols. Disinfected air Scientific-manufacturing firm "Potok Inter" Moscow, Khavskayast 18,Building 2, tel/fax +7(499)678-20-99, www.potok-inter.ru, e-mail: post@potok-inter.ru
“Potok” Technology Anti-Microbial Effect Scientific-manufacturing firm "Potok Inter" Moscow, Khavskayast 18,Building 2, tel/fax +7(499)678-20-99, www.potok-inter.ru, e-mail: post@potok-inter.ru
Air decontaminator “Potok 150-M-01” Sampling Tests • Harvard School of Public Health (USA): • Bacillus subtilis spores • Serratia marcescens • Aspergillus niger • Pseudomonas aeruginosa • Staphylococcus aureus • The State Research Center of Virology and Biotechnology VECTOR, Novosibirsk: • Chicken flu virus • Variolovaccine virus • Gamalei Institute of Epidemiology and Microbiology: • Legionella pneumophylla virulent strain Philadelphia I • Staphylococcus aureus Wood 46 • Е.сoli-K12 • Tuberculosis Central Research Institute: • Mycobacterium bovis BCG • Epidermal staphylococcus • Klebsiella • Pseudomonas species • Bacillus sppecies Scientific-manufacturing firm "Potok Inter" Moscow, Khavskayast 18,Building 2, tel/fax +7(499)678-20-99, www.potok-inter.ru, e-mail: post@potok-inter.ru
“Potok” Technology Key Advantages • Complete decontamination of air from all types of microbes and viruses (including the viruses of chicken flue, pox, legionella, etc.) • Efficiency of decontamination does not depend on the microbe type or viability, as the microbial cell is exposed to physical action, which causes its disintegration (destruction) • Harmless for people • Suitable for continuous and intermittent operation within a wide range of temperature and humidity parameters • Low power consumption (5W will suffice to disinfect 150 cu m of air per hour) • No need of consumables • Long operating life (over 5 years) Scientific-manufacturing firm "Potok Inter" Moscow, Khavskayast 18,Building 2, tel/fax +7(499)678-20-99, www.potok-inter.ru, e-mail: post@potok-inter.ru
Aseptic ceilings with air decontaminators “POTOK 150-M-01” Technical Characteristics Efficiency of microbe and virus inactivation up to 100%, but not less than 95% Efficiency of aerosols filtration corresponds to a high efficiency filter capacity of at least an H14 class Liquid resistance (under rated output capacity) not more than 110 Pa Output capacity 650 … 800 cu m/per hour Power consumption not more than 80 VA “Potok 150-M-01” units in a shared container with the function of air distribution Scientific-manufacturing firm "Potok Inter" Moscow, Khavskayast 18,Building 2, tel/fax +7(499)678-20-99, www.potok-inter.ru, e-mail: post@potok-inter.ru
Air decontaminators “Potok 150-M-01” use for equipping Operating TheatreWith Aseptic Ceilings 'Potok 150M-01' units in operating theaters at Municipal Clinical Hospital named after S.P. Botkin Inner circuit Muffler Inner circuit fan Air intake Muffler Inner inactivating circuit air intake Scientific-manufacturing firm "Potok Inter" Moscow, Khavskaya st 18,Building 2, tel/fax +7(499)678-20-99, www.potok-inter.ru, e-mail: post@potok-inter.ru
Aseptic ceilings with air decontaminators “POTOK” Operating, City Clinical Hospital № 24, Moscow Aseptic ceiling in operating thearte at Municipal Clinical Hospital named after S.P. Botkin Scientific-manufacturing firm "Potok Inter" Moscow, Khavskayast 18,Building 2, tel/fax +7(499)678-20-99, www.potok-inter.ru, e-mail: post@potok-inter.ru
Aseptic ceilings with air decontaminators “POTOK” Hematologic boxes at State Military Clinical Hospital named after N.N. Burdenko Children's Emergency Medicine, Perinatal Center, Tver Scientific-manufacturing firm "Potok Inter" Moscow, Khavskayast 18,Building 2, tel/fax +7(499)678-20-99, www.potok-inter.ru, e-mail: post@potok-inter.ru
Recirculating circuit of ventilation and air conditioning system with the function of air decontamination Advantages • “Potok 150-M-01” allows a safe use of recirculated air • It provides complete inactivation of all the microbes and viruses in the treated air flow • It provides safe continuous and intermittent operation of ventilation and air conditioning system in the patient-care institution • It significantly reduces operating costs • It ensures stable liquid resistance throughout the system operating life “Potok 150-M-01” units in a shared container ready for installation into the recirculating circuit of ventilation system Scientific-manufacturing firm "Potok Inter" Moscow, Khavskayast 18,Building 2, tel/fax +7(499)678-20-99, www.potok-inter.ru, e-mail: post@potok-inter.ru
Creation of Clean Premises on “Potok-150-M-01”bases with recirculated air Technical Characteristics Efficiency of microbe and virus inactivation up to 100%, but not less than 95% Efficiency of aerosols filtrationcorresponds to a high efficiency filter capacity of at least an H14 class Liquid resistance (under rated output capacity) not more than 110 Pa Output capacity 130...600 cu m/per hour Power consumption not more than 60 VA Recirculating circuit in operating thearters at Municipal Clinical Hospital No1 named after N.I. Pirogov Scientific-manufacturing firm "Potok Inter" Moscow, Khavskayast 18,Building 2, tel/fax +7(499)678-20-99, www.potok-inter.ru, e-mail: post@potok-inter.ru
AIR DECONTAMINATOR “POTOK 150-M-01” Portable air decontaminator “Potok 150-M-01” Stand Alone air decontaminator “Potok 150-M-01” Scientific-manufacturing firm "Potok Inter" Moscow, Khavskayast 18,Building 2, tel/fax +7(499)678-20-99, www.potok-inter.ru, e-mail: post@potok-inter.ru
APPLICATION OF AIR DECONTAMINATOR“POTOK 150-M-01” OtolaryngologyState Military Clinical Hospital named after N.N. Burdenko Operating theater at a research and practical center (Solntsevo) Scientific-manufacturing firm "Potok Inter" Moscow, Khavskayast 18,Building 2, tel/fax +7(499)678-20-99, www.potok-inter.ru, e-mail: post@potok-inter.ru
AIR-DECONTAMINATOR “POTOK 150-M-01RW” FOR VENTILATION AND AIR CONDITIONING SYSTEM IN THE PASSENGER CARRIAGE Passenger Transport Biological Safety Issues: • Provision of epidemiological safety during passenger traffic • Prophylactics of penetration and spread of infectious diseases through passenger transport • Creation of favorable conditions for the delivery of medical care to passengers at airports,railway terminals, stations and on passage • Health protection of the railroad employees and servicing personnel • Prophylactics and medical support of the railroad accidents management Scientific-manufacturing firm "Potok Inter" Moscow, Khavskayast 18,Building 2, tel/fax +7(499)678-20-99, www.potok-inter.ru, e-mail: post@potok-inter.ru
Provision of Biological Safety during Passenger Traffic usingAir decontaminator “Potok 150-M-01 Exhaust air discharge “Potok 150-M-01 RW” Central air duct Service compartment Air-conditioner Outside air intake Disinfected air Passenger compartments Recirculated ai Passage corridor Scientific-manufacturing firm "Potok Inter" Moscow, Khavskayast 18,Building 2, tel/fax +7(499)678-20-99, www.potok-inter.ru, e-mail: post@potok-inter.ru
Main Technical Characteristics and Advantagesof “Potok 150-M-01 RW” Air Decontamination and Fine Filtration Technical Characteristics Output capacity up to 225cu m/per hour Liquid resistance not more than 150Pa Power consumption up to 12VA Weight 7kg Dimensions 310x610x63mm • Advantages • It decontaminates the air from all types of microbes and viruses without doing harm to people orthe environment • It is suitable for continuous and intermittent operation within a wide range of temperature andhumidity parameters • It is installed in the space behind the compartment ceiling or in the interior wall panels Scientific-manufacturing firm "PotokInter“, Moscow, Khavskayast 18,Building 2, tel/fax +7(499)678-20-99, www.potok-inter.ru, e-mail: post@potok-inter.ru
AIR DECONTAMINATION ON BOARD A SPACESHIP • “Potok 150MK” use on board a spaceship can improve air quality • Experiments carried out on board the 'Mir' Station and on board the International Space Station confirm the efficiency of Air decontaminator 'Potok150MK‘ • Air decontaminator “Potok 150MK” has been highly praised by the astronauts, who pointed out its beneficial influence on the air , on their health and on the station equipment Gennadiy Padalka, 'Mir' Station • “Potok 150MK” Advantages • “Potok 150MK”provides complete destruction of microbes and viruses • It provides high level of filtration of the disinfected air • It does not change gaseous or ion composition of the air • It decontaminates the air in closed spaces without doing any harm to people or spaceship environment Nikolay Budarin, Zvezda DOS-8 Servis Modul Oleg Kotov, Zarya FGB Scientific-manufacturing firm "Potok Inter", Moscow, Khavskayast 18,Building 2, tel/fax +7(499)678-20-99, www.potok-inter.ru, e-mail: post@potok-inter.ru
SUCCESSFUL USE OF “POTOK” TECHNOLOGY Decontamination of sour cream on the bottling line using “Potok 150-M-01”unit (in food production) Aeromobile hospital of EMERCOM of Russia Scientific-manufacturing firm "Potok Inter“, Moscow, Khavskayast 18,Building 2, tel/fax +7(499)678-20-99, www.potok-inter.ru, e-mail: post@potok-inter.ru