1 / 28

Automated meter data management software

Automated meter data management software. PrimeRead Software. Better device data access. PrimeRead software gives utilities multi-vendor, automated data collection offers large-scale commercial and industrial (C&I) data acquisition. PrimeRead software provides:

jared-mason
Download Presentation

Automated meter data management software

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Automated meter data management software PrimeRead Software December 2008 PrimeRead Software

  2. Better device data access • PrimeRead software gives utilities multi-vendor, automated data collection offers large-scale commercial and industrial (C&I) data acquisition. • PrimeRead software provides: • Communications network flexibility • Configurable data validation • A true Windows interface • Meter data management for AMI • Validation, estimating and editing

  3. PrimeRead software summary • A multi-tier, open architecture makes PrimeRead software flexible and scalable • Support for industry-standard SQL Server and Oracle databases allows data exchange with other corporate information systems such as: • Billing • Operations • Customer Information Systems • SCADA • Power Quality Systems • Energy Balance and Losses • ISO/RTO • Securely store information in one central database

  4. PrimeRead software summary • Easily read and display power quality information from your meters • Import interval data, waveforms, PQ events and more from multiple utility devices (electricity, water and gas)

  5. PrimeRead software operations • Business Analysis for easy ad-hoc reporting, scheduled reporting, graphing and exporting data • Set up call schedules, make on-demand calls and perform troubleshooting communications • Configure devices, system parameters, customer information, TOU schedules and groups • Unpack data retrieved from meters and store it in the centralized, secure database. Easily troubleshoot and log issues with this tool • Configure automatic and user-defined validation routines and schedules, or access the estimation and editing functions • *Unlisted modules are Importer and I/O

  6. Multi-vendor Multi-networking Open architecture Backward compatibility with legacy systems Advanced user interface Global parameters User-defined fields for customer and for devices Channel, registers, event and waveform download Advanced port group functionality Online data analysis Groups or data aggregation structures Time of Use Unlimited scheduled reporting Automated data collection Online data validation Audit log for configuration and validation Key features

  7. Elster – ABB Alpha I Alpha II or Plus Alpha 3 AIN REX – MAS Residential IEC A-1000 series Actaris SL-7000 Aldana Enerlux American Innovations Cewe Prometer Circutor Extensive device support • Datapro Datapower • Electro Industries • Nexus 1250 DNP and Modbus • Nexus 1270 DNP and Modbus • EDMI • K3 • K6 • ELO Spectra • EMH Elgama • First Point TDS-2

  8. General Electric DR-87 Phase 3 KV KV2 KV2c Iskra MT851 Poreg 2 L+G – Bayard Altimus LG-100 S3 S4 S4e DXMS DXMX ZMC ZMD ZMU Nansen Spectrum PowerLogic ION7650 ION8600 Quadlogic Transponder S-20 Minicloset Schweitzer SEL DNP Modbus Hunt Power Emon IDR Emon MS-5000 Extensive device support (continued)

  9. Scientific Columbus – Ametek Jem10 JemStar Transdata Mark V SSR-5000 Schlumberger - Itron Datastar Recorder Fulcrum SL 320 Fulcrum SQ-400 Q-1000 Quantum (Q100 & Q200 series) Quantum QDIP Sentinel Vectron Siemens Maxsys 2410 Maxsys 2510 Quad 4 Plus (w/o Superboard) Quad 4 Plus (Superboard) Sentry Recorder 200 Triacta Powerhawk ZIV Standard Protocols IEC 61107 DLMS IEC 870-5-102 ANSI C12.19 Extensive device support (continued)

  10. Landlines Cellular (TDMA, CDMA & GSM) Cellular digital CDMA 1X-RTT/EVDO, GPRS/EDGE Fixed IPs Dynamic IPs CDPD (point to point and TCP/IP) Satellite (TCP/IP) Daisy Chain master-slave Optical Probes ANSI IEC Radios Utilinet – Cellnet TCP/IP Power line carrier (PLC) RS-232 Direct RS-485 (multi-drop) Ethernet Line Simulators Line splitters X25 Multi-networking

  11. Multi-tiered, open architecture • Flexible enough for application distribution over a network environment or over a geographically dispersed area • Dynamically updates all stored information each time you perform an operation • Supports industry-standard SQL Server and Oracle databases • A native 32-bit application provides all current Windows operational and connectivity options and decreases the learning curve

  12. Open architecture Analysis and Reports Data Collection Data Collection Validation Central Data Base: Oracle SQL Server Client – Server Multi-tier Mobile Users PDAs W2000, XP, SP2, 2003 Server

  13. Backward compatibility with legacy systems • PrimeRead software’s relational database provides: • Fast import of historical data into the software • A universal import and export engine for exporting data as flat files or XML to billing systems, SCADA or data warehouses: • Support for specific formats: • MV-90 Masterfile import • Lotus PRN import/export • EU export • MDEF export • EDI 867 import/export • Lodestar export • XML • CMEP

  14. Advanced user interface • Outlook-style interface with: • Navigation bars • Floating toolbars • Develop grids that allow you to: • Group • Sort • Filter • Select columns • Create ad-hoc reports with grid information • Grid information can be exported to: • Text • HTML • Excel • XML • Grids allows volume handling of data

  15. Global parameters with individual customization • On-line data validation for the following validation checks: • Energy Tolerance • Interval Tolerance • Zero Tolerance • Non-Zero Tolerance • Time Tolerance • Overflow Tolerance

  16. Global parameters with individual customization • DST • Global parameter that may be customized individually • Time Synchronization • Global parameter that may be customized individually

  17. User-defined customer and device fields • 50 User-defined fields for: • Customers • Devices • These fields are associated in the database and: • Link customer data with external information systems • Link device data with external information systems • Store custom information

  18. Channel, registers and event download • User-defined channel definitions • These are associated to the physical channels inside the devices • Registers may be downloaded from the devices • Registers may be selected for download • Events and power quality data may be downloaded

  19. Advanced port group functionality • For serial port data collection only • Allows similar ports on several workstations to launch calls • Scheduled calls are in the database, not the data collection station • Provides load balancing between the data collection workstations • Provides a fault tolerant operation • Allows specific modem configuration strings to be assigned to port and device combination

  20. Online data analysis • Business Analysis Module features: • Online data analysis using decision cubes • Based on creation of simple filters: • Multiple filters may be applied • Unlimited number of filters may be created • Filters may be used in other areas in the application • Graphs may be generated from the cube data • Multiple types of graphs

  21. Groups and data structure • Unlimited number of groups or data structures may be created thus allowing: • Totalization or aggregation • Device characterization and data mining functionality • Groups, which may be used for: • Reports • Decision cube in Business Analysis Module • Call groups • Totalization is accomplished using dynamic tables

  22. Time of Use • Based on creation of TOU calendars • Create an unlimited number of calendars • Apply any of the following attributes: • Seasons • Day types, each day type may have its own TOU rate structure • Up to 365 day types for each calendar • TOU rates • Up to 48 changes per day • The calendars are applied dynamically to the database • View the calendars applied to the database in the Business Analysis Module

  23. Scheduled report generation • Based on Crystal Reports • Create an unlimited number of reports • Or choose from more than 100 standard reports • Schedule report generation • Generate reports in a variety of formats including: • EU • Lotus PRN • EDI 867 • Lodestar • Excel • HTML • Word • CSV

  24. Automated data collection • Calls can be permanently scheduled: • Individually • Using groups • Data collection may be accomplished using multiple data collection stations • No user intervention is required for data collection

  25. Online data validation • Validation is automatic for selected channels • The channel data has a flag that allows verification of the validation from an external source • Validation may be accomplished on any workstation in the system • Interactive data estimating • Manual data editing

  26. Audit log for configuration and validation • Allows tracking of changes made in both Configuration and Validation modules

  27. In conclusion… • PrimeRead software is an easy to use tool • Provides multi-vendor, automated data collection for utilities • Offers communications network flexibility, configurable data validation and a true Windows interface • Makes C&I data collection more flexible, scalable and reliable

  28. Need more information? • Visit us on the web at: • www.powerlogic.com

More Related