1 / 9

Rev: 2010-03-01

EMIT ESD Monitoring, Ionization & Test. SmartLog V5™ ESD Data Acquisition System. Rev. 2013-05. Rev: 2010-03-01. Features and Benefits.

jasia
Download Presentation

Rev: 2010-03-01

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. EMIT ESD Monitoring, Ionization & Test SmartLogV5™ ESD Data Acquisition System Rev. 2013-05 Rev: 2010-03-01

  2. Features and Benefits The patented* EMIT SmartLog V5™ is designed for fast, frequent, and accurate testing of ESD personnel grounding items. Its unique design embeds an ESD tester, computer clock, keypad, barcode scanner, Ethernet module and proximity badge reader (optional) into a compact stainless steel enclosure. By touching the electrode button once, the SmartLog V5™ tests the resistance path limits of the worn wrist strap and both worn ESD footwear independently within two seconds. It may also test a worn ESD garment if it is used as part of personnel grounding path. Test results are electronically stored in the SmartLog V5™ and are easily downloaded to a PC for logging records and evaluation. • System Benefits: • Verifies the required limits of operator’s wrist strap and/or footwear per ANSI/ESD • S20.20 and ESD TR53 • Creates and stores electronic records of test results* • Access and manage test results and requirements with TEAM5 software interface • Improves accuracy of ESD test records and eliminates paper logs *US Patent 6,078,875 & 6,809,522 “Compliance verification records shall be established and maintained to provide evidence of conformity to the technical requirements.” (ANSI/ESD S20.20-2007 section 7.3)

  3. Added Benefits Paperless data can enhance operator accountability, immediately identifying problems while reducing logging and auditing costs. Paper log systems can initially be effective but have proven to be inaccurate and ignored over time. Paper log systems are also limited to what information is documented and poses the following questions: • Do your paper logs show any failures?* • If a Pass entry is logged, do you know that the test was actually made? • If a Pass entry is logged, do you know who actually made the entry? • If a Pass entry is logged, do you know if they failed previously? • If no entry is logged, do you know if the person worked that day? • Is calibration of each tester tracked on the same paper log? • Do you keep track of smock and ESD shoe testing? • Are pass entries logged for future days?* • Do your paper logs identify the type of test performed per operator? * Common occurrences The EMIT SmartLog V5™ automates the entire ESD verification process assuring all the data collected is valid and unaltered.

  4. More Features Stainless Steel Enclosure NEW stainless steel enclosure provides increased durability and a modern, industrial look. Mounting Bracket NEW stainless steel mounting bracket allows the SmartLog V5™ to be easily taken down from an installation site without having to remove several screws. Simply remove one thumbscrew to disconnect the SmartLog V5™ from the bracket. Proximity Reader NEW optional HID iClass proximity reader offers instant recognizing of employees proximity badges Embedded Ethernet Module NEW embedded Digi Ethernet module eliminates the risk of tampering. Use the Ethernet module to communicate with your SmartLog V5™ over a secured LAN network. CCD Barcode Scanner NEW CCD barcode scanner uses LEDs instead of lasers for user safety and improved equipment life. The scanner reads over 10 barcode symbologies including Code 39 and Code 128. Foot Plate Detection NEW foot plate detection will alert the user when the foot plate cable is disconnected or damaged. The footwear LEDs will flash and prevent tests from being performed. Connection Cover NEW connection cover prevents unauthorized tampering to the SmartLog V5™'s cable connections. A single opening at the bottom provides an organized method to route your cables.

  5. Specifications RELAY TERMINAL High Contrast LCD Display Ground Jack POWER SOURCE 0 - 120 V AC / DC BELL BUZZER DOOR LOCK LIGHT OTHER NORMALLY OPEN HOT COMMON / NEUTRAL Relay Terminal Optional Proximity Reader Location RESISTANCE VALUES Foot Plate Jack Solid State Test Switch Ethernet Jack (Network Connection) Dual-Wire Wrist Strap Jack DIP Switches (Adjustable Resistance Values) Single-Wire Wrist Strap Jack CCD Barcode Scanner

  6. Mounting Options Wall Mount The new mounting bracket allows the unit to be mounted and removed without the use of any tools. Install the bracket to a flat surface and secure the SmartLog V5™ with the included thumbscrew. Stand Use the EMIT 50415 stand as an alternative method to mounting the SmartLog V5™ on a wall. It features a heavy gauge, powder-coated steel construction for minimized corrosion and contamination. Turnstile Use the new EMIT 50773 SmartLog V5™ Turnstile to provide access control to your ESD test program. Users must pass their predefined ESD test in order to activate the turnstile. Its construction is entirely stainless steel and made in the United States of America for superior reliability.

  7. Turnstile Ready • Simple activation • Timed delay auto relock • Reversible arm rotation • Stainless steel design • Adjustable SmartLog V5™ mounting base • Mounting bracket can be sold separately (contact the factory) • Hole pattern for bracket will be provided by the EMIT factory

  8. TEAM5 Software The TEAM5 software manages personnel and test data for personal ESD grounding devices. Test and personnel data may be viewed/reported locally, via a network web page and emailed automatically on a scheduled or on-demand basis. Robust and easy to use sort/filter capabilities are built in to all reporting controls. TEAM5 uses date/time stamps on all user requirement changes to comply with quality control and record keeping requirements. This ensures archived tests are always linked to historically accurate personnel data, test requirements. TEAM5 automatically maintains backups in a redundant network storage area. The SmartLog V5™ ESD test stations and Network (Multi User) programs operate semi-autonomously to ensure continuous operation even while network or server outages occur. WINDOWS COMPATIBILITY SYSTEM REQUIREMENTS Windows 2003 Server Windows 2008 Server Windows XP SP3 (Recommended) Windows 7 (All Versions) 2GB Program and Database Disk Space 8GB Backup Disk Space 2GB RAM 1024 x 768 display resolution 1 available USB port 1 or more SmartLog V5™ devices Full details on the TEAM5 software can be found at emit.descoindustries.com

  9. SmartLog V5™ Need More Information? For a demonstration of more information please contact the EMIT factory for your local sales representative. EMIT 3651 Walnut Ave Chino, CA 91710 Phone: (909)664-9980 Fax: (909) 627-7449 Website: DescoEMIT.com

More Related