KATRIN - The Ka rlsruhe Tri tium N eutrino Experiment

KATRIN - The Ka rlsruhe Tri tium N eutrino Experiment. H.H. Telle Department of Physics, University of Wales Swansea Singleton Park, Swansea SA2 8PP. HHT – UK HEP “Dark Matter” (15/05/05) 1. What is KATRIN.

Download Presentation

KATRIN - The Ka rlsruhe Tri tium N eutrino Experiment

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. KATRIN - The Karlsruhe Tritium Neutrino Experiment H.H. Telle Department of Physics, University of Wales Swansea Singleton Park, Swansea SA2 8PP HHT – UK HEP “Dark Matter” (15/05/05) 1

  2. What is KATRIN The KATRIN experiment is designed to measure the mass of the electron neutrino directly with a sensitivityof 0.2 eV. It is a next generation tritium beta-decay experiment scaling up the size and precision of previous experiments by an order of magnitude as well as the intensity of the tritium beta source. 10 m HHT – UK HEP “Dark Matter” (15/05/05) 2

  3. Who and Where KATRIN is a joint effort of several European and U.S. institutions. Currently there are about 100 scientists, engineers, technicians and students involved, including most of the groups that have worked on tritium beta-decay experiments in recent years. KATRIN is being built at Forschungszentrum Karlsruhe in Germany where much of the required technical infra-structure is already available, especially for the tritium source. HHT – UK HEP “Dark Matter” (15/05/05) 3

  4. The location HHT – UK HEP “Dark Matter” (15/05/05) 4

  5. Why The widely-used Standard Model (SM) of particle physics originally assumed neutrinos to be mass-less. However, actual investigations of neutrinos from the sun and of neutrinos created in the atmosphere by cosmic rays have given strong evidence for massive neutrinos indicated by neutrino oscillations. Neutrino oscillations imply that a neutrino from one specific weak interaction flavour, e.g. a muon neutrino νµ, transforms into another weak flavour eigenstate, i.e. an electron neutrino νeor a tau neutrino ντ, while travelling from the source to the detector. HHT – UK HEP “Dark Matter” (15/05/05) 5

  6. Neutrino mass determination methods HHT – UK HEP “Dark Matter” (15/05/05) 6

  7. Neutrino mass: a source for “hot” dark matter (HDM) The contribution Ων from neutrino HDM to the total matter energy density Ω of the universe spans two orders of magnitude. The lower bound on Ων comes from the analysis of oscillations of atmospheric ν’s. The upper bound stems from current tritium β-decay experiments and studies of structure formation. HHT – UK HEP “Dark Matter” (15/05/05) 7

  8. The experiment HHT – UK HEP “Dark Matter” (15/05/05) 8

  9. Overview of KATRIN set-up scale 1 2 3 4 5 Overview of the KATRIN setup. The electron path is from left to right. To minimise background, an ultra high vacuum of better than 10-11 mbar is necessary. HHT – UK HEP “Dark Matter” (15/05/05) 9

  10. 1 – the source T2 injection HHT – UK HEP “Dark Matter” (15/05/05) 10

  11. 2 – the transport section The electron transport system adiabatically guides beta decay electrons from the tritium source to the spectrometer, while at the same time eliminating any tritium flow towards the spectrometer, which has to be kept practically free of tritium for background and safety reasons. HHT – UK HEP “Dark Matter” (15/05/05) 11

  12. 3 – the pre-spectrometer Between the tritium sources and the main spectrometer a pre-spectrometer of MAC-E-Filter type will be inserted, acting as energy pre-filter to reject all β electrons except the ones in the region of interest close to the endpoint E0. HHT – UK HEP “Dark Matter” (15/05/05) 12

  13. The MAC-E filter MAC-E-Filter = Magnetic Adiabatic Collimation combined with an Electrostatic Filter Varying the electrostatic retarding potential allows to measure the beta spectrum in an integrating mode. HHT – UK HEP “Dark Matter” (15/05/05) 13

  14. The hardware status of the pre-spectrometer HHT – UK HEP “Dark Matter” (15/05/05) 14

  15. 4 – the main spectrometer (1) A key component of the new experiment will be the large electrostatic spectrometer with a diameter of 10m and an overall length of about 23m. This high resolution MAC-E-Filter will allow to scan the tritium endpoint with increased luminosity at a resolution of < 1eV, which is a factor of 4 better than present MAC-E Filters. HHT – UK HEP “Dark Matter” (15/05/05) 15

  16. 4 – the main spectrometer (2) HHT – UK HEP “Dark Matter” (15/05/05) 16

  17. 5 – the detector (1) • All β particles passing the retarding potential of the MAC-E-Filter will be guided by a magnetic transport system to the detector. • The detector requirements are the following: • high efficiency for e-detection and simultaneously low g background, • energy resolution of ΔE < 600 eV for 18.6 keV electrons to suppress background events at different energies, • operation at high magnetic fields, HHT – UK HEP “Dark Matter” (15/05/05) 17

  18. 5 – the detector (2) • position resolution to map the source profile, to localize the particle track within the spectrometer (for compensation of inhomogeneities of electric potential and magnetic field in the analyzing plane), and to suppress background originating outside the interesting magnetic flux (e.g. coming from the electrodes of the spectrometer), • for a measurement in a MAC-E-TOF mode, a reasonable time resolution < 100 ns), • n for test and calibration measurements ready to take high count rates (up to total rate of order 1 MHz) HHT – UK HEP “Dark Matter” (15/05/05) 18

  19. Time schedule Numerous parts have been delivered and are under test All major components (source and main spectrometer) have been ordered Work on new buildings commenced Full commissioning and test of whole assembly in late 2007 Start of measurements: 2008 Duration of measurements: 3-5 years HHT – UK HEP “Dark Matter” (15/05/05) 19

  20. Costs Capital investment – about € 32 M (mostly provided by the Helmholtz Gesellschaft and the German Federal Government) Operating costs from 2007/8 onwards – about € 1.5 M p.a. (to be shared by the participating countries) HHT – UK HEP “Dark Matter” (15/05/05) 20

  21. The scientific contribution from the UK Swansea Development of a monitoring system for T2 purity Calculation of trajectory distortion of -particles from space charge and electrode edges University College London Calculation of final molecular state distributions in the WGTS CCLRC Daresbury expertise in XUHV HHT – UK HEP “Dark Matter” (15/05/05) 21

  22. Requirements for T2 analysis • KATRIN requires T2 gas of high (>95%) purity. • Impurities include the other hydrogen isotopomers (H2, HT, D2, DH, DT) and possibly small amounts of methane isotopes CHxRy (R=H,D,T) from chemical reactions. • In the long-term, knowledge of the T2 purity to within ±0.1% is needed, with Raman spectroscopy providing quantitative information about the impurities. • Measurements of impurities to be done at the inlet* to the T2 source at a total pressure of ~10mbar • * Identified as the most convenient location for continuous • in-line analysis HHT – UK HEP “Dark Matter” (15/05/05) 22

  23. Principles of Raman spectroscopy excited state Vibrational states: v=0,1,2,3… Rotational states: J=0,1,2,3… Laser excites the molecule to an excited state which scatters: either to the same initial vibrational state, with DJ = 0,+2 or to a higher vibrational state, with DJ = 0, ±2 lro-vib J llaser lrot 2 1 J 0 v=1 2 1 0 v=0 HHT – UK HEP “Dark Matter” (15/05/05) 23

  24. Raman spectroscopy of H2 ~550,000 H2 rotational ro-vibrational S0O1 Q1 S1 HHT – UK HEP “Dark Matter” (15/05/05) 24

  25. Proposed experimental set-up at FZK By-Pass Area Allocated To Raman Monitoring 120cm Monitoring Gas Cell 180cm WGTS T2 safety enclosure HHT – UK HEP “Dark Matter” (15/05/05) 25

  26. Experimental set-up for realisation of H2 / D2 / T2 Raman HHT – UK HEP “Dark Matter” (15/05/05) 26

  27. The test set-up for H2 / D2 Raman HHT – UK HEP “Dark Matter” (15/05/05) 27

  28. Test – Raman of ambient air (8mW laser) HHT – UK HEP “Dark Matter” (15/05/05) 28

  29. Test – Raman of D2 (8mW laser) S0(S) D2 S1(Q) D2 Nd:YAG S1(Q) O2 S1(Q) N2 HHT – UK HEP “Dark Matter” (15/05/05) 29

  30. Test – Raman of H2+D2 mixture (8mW laser) Not yet sufficient resolution to follow rotational population of all isotopomers HHT – UK HEP “Dark Matter” (15/05/05) 30

  31. Estimates for estimated Raman sensitivities HHT – UK HEP “Dark Matter” (15/05/05) 31

  32. The remit of KATRIN KATRIN is expected to achieve the following sensitivities for the mass of the electron neutrino: Sensitivity: (90% upper limit if neutrino mass is zero) 0.2 eVwith about equal contributions of statistical and systematical errors. Discovery potential: A neutrino mass of 0.35 eV would be discovered with 5 sigma significance.A neutrino mass of 0.30 eV would be discovered with 3 sigma significance. HHT – UK HEP “Dark Matter” (15/05/05) 32

  33. Accuracy on mν2 for 3-year data taking (calculation -1) . HHT – UK HEP “Dark Matter” (15/05/05) 33

  34. Accuracy on mν2 for 3-year data taking (calculation-2) • Systematic uncertainties are expected to amount to an equal size as the statistical errors after a measuring time of 3 full years, using an analyzing interval of 30 eV below the endpoint. These are especially: • Time variation of parameters of the Windowless Gaseous Tritium Source (WGTS), • description of space charging within the WGTS, • determination of scattering probabilities of β-electrons within the WGTS, • description of the final state distribution of (3HeT)+ ions after tritium decay, • variations of the retarding potential, • and the limited uniformity of the magnetic and electrostatic fields in the spectrometer analyzing plane. . HHT – UK HEP “Dark Matter” (15/05/05) 34

  35. Summary of expectation from KATRIN now originally HHT – UK HEP “Dark Matter” (15/05/05) 35