ตัวอย่าง Domino Effect

ตัวอย่าง Domino Effect. Lead in PWB Assemblies. Major Lead Usage: Interconnection Surface Finishing. Practical Peak Temperature. Q = Heat Absorbed (W/cm 2 ) A = Exposed Area (cm 2 ) t = Heating Dwell Time (seconds) M = Mass of Object (kg) C p = Specific Heat (W-sec/kg- ° C).

Download Presentation

ตัวอย่าง Domino Effect

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. ตัวอย่างDomino Effect

  2. Lead in PWB Assemblies • Major Lead Usage: • Interconnection • Surface Finishing

  3. Practical Peak Temperature Q = Heat Absorbed (W/cm2) A = Exposed Area (cm2) t = Heating Dwell Time (seconds) M = Mass of Object (kg) Cp = Specific Heat (W-sec/kg-° C)

  4. Practical Peak Temperature • Typical SnPb Reflow peak ~ 210-225°C • ~225°C-183°C = 42°C Superheat • SnAgCu melting point ~ 217°C • Peak T ~ 217°C +42°C ~ 260°C!!! • Can board and components tolerate this peak??? • Warpage, Delamination, Popcorn Effect

  5. Component Reliability

  6. Practical Peak Temperature Ambient changes everyday, Input product/raw mat. change lot by lot Equipment drift, Measurement drift Almost NO room for error!

  7. Voids Cu Diffusion?