DC photogun vacuum characterization through photocathode lifetime studies

DC photogun vacuum characterization through photocathode lifetime studies . Marcy L. Stutzman, Philip Adderley, Joseph Grames, Matthew Poelker, Ken Surles-Law Thomas Jefferson National Accelerator Facility Newport News, Virginia, USA . Jefferson Lab. A. C. B.

jeri
Download Presentation

DC photogun vacuum characterization through photocathode lifetime studies

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. DC photogun vacuum characterization through photocathode lifetime studies Marcy L. Stutzman, Philip Adderley, Joseph Grames, Matthew Poelker, Ken Surles-Law Thomas Jefferson National Accelerator Facility Newport News, Virginia, USA

  2. Jefferson Lab A C B • CEBAF: Nuclear physics electron accelerator laboratory • 100 kV DC polarized electron gun • Recirculating linear accelerators • Three experimental halls running simultaneously • User community of 2000+ physicists • Operates 310 days/year, 24 hours/day • FEL program at JLab

  3. GaAs Photoelectron gun 100 kV 200 μA 85% polarization delivers beam simultaneously to three experimental halls CEBAF pressures ~1.2x10-11 Torr Guns pumped with combination of NEG and ion pumps Existing CEBAF photoguns • Gun chambers vented and baked each time new photocathode installed • Activation chemicals in HV chamber • Full NEG activation may harm photocathode

  4. Vacuum Characterizations Outgassing Rate Ultimate Pressure • Ultimate Pressure discrepancy • Outgassing rates • Accumulation with spinning rotor gauge • throughputmethod • good agreement • Untreated 304 SS as expected • EP/vacuum fire (900ºC, 4 hrs) • slightly better • fewer bakes • fits to guide the eye • Outgassing rate does not explain ultimate pressure discrepancy

  5. Pump speed measurement Ti/Zr/V coating ST707 Getter • Hydrogen Pump speed measurements • SAES getter ST707 • WP950 modules • Throughput method • High speed >5x10-11 Torr • Activation protocol increases pump speed • Decrease at low pressures • Pressure measurement? • Artifact of measurement? • Homemade NEG coating • Higher pressures • Same behavior • Still no explanation for ultimate pressure discrepancy

  6. Photocathode lifetime to diagnose vacuum • GaAs photocathode activated with cesium and NF3 or O2 • Quantum efficiency (QE) falls during operation • Electrons out per unit photons in • Mechanism for QE decay: • Surface chemistry corruption • Crystal damage • Both mechanisms dependent on vacuum laser light IN electron beam OUT anode residual gas cathode

  7. Load-locked future of JLab gun • Successfully run program so far with “vent and bake” gun • Upcoming experiments with very high current (300 μA) will require frequent cathode maintenance • Load-locked designs allow • Faster cathode change • Separation of surface chemistry from • High voltage electrodes • High voltage (HV) chamber vacuum • Allow full activation of NEG cartridges in HV chamber

  8. 304 Stainless Steel Electropolished, not vacuum fired Cartridge getter pumps on 8 inch ports Conductance limitations 220 L/s ion pump Does fast pump speed imply good ultimate pressure? Photocathode heating in relatively poor vacuum of load chamber Prototype CEBAF LL gun

  9. New CEBAF load-locked gun Heat/activation chamber • To be installed July, 2007 • High voltage chamber • 304 SS • Electropolished • vacuum fired • NEG coated • Smaller surface area • NEG modules surround cathode/anode gap • Full NEG activation possible Suitcase HV chamber Small bake Load region Additional Benefits • Photocathode activation through mask • Four photocathodes can be exchanged in 12 hours

  10. Vacuum measurements • Significant design improvement • Extractor gauge readings no better • Gauge characterization (x-ray limit) • Gauge utilization (electrometer, cables) New LL Tunnel prototype LL

  11. Photocathode lifetime improvement • Lifetime improves with better vacuum design • factor >2 • Damage analysis: TEM, SIMS • Improve vacuum design regarding most damaging species Bulk GaAs, green light Ref: J. Grames et. al SPIN 2006 Kyoto

  12. High Polarization Superlattice Lifetime • Tunnel: Lifetimes at high polarization typically ~100 Coulombs running ~100 μA • New LL gun: Lifetimes over 200 Coulombs at 250 μA or 1 mA on test beamline • We anticipate (hope for!) improved lifetime during operation with new load lock new load lock operational gun Reference: J. Grames et. al PAC’07 proceedings

  13. Conclusions • Vacuum improvements incorporated during construction of New LL gun • Little improvement seen in ultimate pressure measurement • Significant improvement in photocathode lifetime • Future work • Better materials • 316 LN electropolished, then baked at 400ºC for ~1 week - JLab FEL • Ion pump limitations? • Anticipate positive operational experience with new LL gun in CEBAF machine • Future machines: ILC, EIC, UV FELs…