18 FAQ of injection molding machine mold clamping
This article summarizes 18 FAQs about injection molding machine clamping failure analysis and repair. I hope it can help those in need. If there are other FAQs, please comment at the end of the text, we will add them to the article, thank you. Question1. Semi-automatic state, it is still in high-pressure mode after clamping in place. Answer 1.1. There is no mode-locking(Lock mold components) termination signal feedback or the high voltage time is too long. 1.2. The limit switch for mold clamping termination is broken. 1.3. The mold-locking termination switch wire is broken. 1.4. Computer I/O check. Question2. After the mold is locked, during the injection process, the crankshaft retracts a bit, causing the mold-locking termination switch to fail to sense, and the injection action cannot be continued.