Information Systems Security Physical Security Domain #4
Physical Security Areas • Threat Types • Threat Sources • Vulnerabilities • Physical Organization • Current Measures • Physical Security Procedures • Environmental Controls • Physical Barriers
Threat Types • Environmental • Malicious • Accidental
Layered Defense • Site Location • Physical and Procedural Methods • Physical Controls • Guard Post • Visitor Security • Delivery Security • Fire Control
Fire Detection Systems • Ionization – Reacts to charged particles in smoke • Photoelectric – Reacts to changes in or blockage of light caused by smoke • Heat – Significant changes in ????
Physical Controls • Fencing • Lighting • Locks • Mantraps • Dogs • Guards
Location Consideration • Natural Disasters • Local Crime • Highway/airport access • Customer access • Joint tenants • Proximity to emergency services • Visibility????
Construction Issues • Building Codes • Levels of fire resistance • Data Center Location • No basements or top floors • Controlled access • Do not use partitions
Physical Controls • Locks • Conventional • Pick-resistant • Electronic key systems • Electronic combination lock
Facility Access • Photo ID viewed by a guard • Biometric devices • Card badge reader • Proximity devices • User activated • System sensing • AVOID PIGGYBACKING • Use mantraps
Fencing • 3-4 Feet – deters casual trespassers • 6-7 Feet – hard to climb easily • 8 Feet with 3 strands of barbed wire BEST • Powered Fences • PIDAS Fences • Perimeter Intrusion Detection and Assessment System
Lighting • Required in critical areas • Ensure there are no dead zones • Two candle feet of power at eight feet high
Guards • Best deterrent, but most expensive • Provides discriminating judgment • Watches for piggybacking and suspicious activity • Enforce regulations
Types of Physical IDS • Electro-mechanical • Magnetic switches • Metallic foil in windows • Pressure mats • Volumetric • Vibration • Photoelectric • Ultrasonic and passive infrared
Mobile Devices • Locking cable to anchor • Tracing software • Encryption • Biometric controls
HVAC • Positive air pressure • Air goes out when doors are opened • Protect vent • Dedicated power lines • Emergency switch-off valves • Same rules for water supply
Electrical Power • Dependable primary power source • Alternative power source • Generator • UPS (online and standby) • Additional feeder from substation • Power not always clean and constant • Voltage fluctuations
Power Terms • Fault – momentary loss of power • Blackout – complete loss of power • Sag – momentary low voltage • Spike – momentary high voltage • Surge – prolonged high voltage • Noise – steady interfering disturbance • Transient – short noise disturbance
Electrical Consideration • High Humidity • Can cause corrosion • Low Humidity • Can cause static electricity • Also use antistatic flooring in server areas • Wear antistatic bands when working on internal computer systems
Recommendation • Computer room 60-75 Fahrenheit • Humidity 40% - 60% • 17,000 volts damages circuits
Fire Prevention • Four legs of fire • Heat (Reduce Temperature) • Fuel (Remove fuel) • Oxygen (Remove oxygen) • Chemical Reaction (Disrupt chemical combustion)
Fire Detection Systems • Configured to call fire station • Shuts down HVAC • On and above suspended ceilings • Below raised floors • In air ducts
Extinguishers • Halogenated • Used in place of water • FM-200 • Replacement for Halon • Carbon Dioxide • Does not damage sensitive devices • Dry Chemicals • Not effective against electrical fires
Water Pipes • Wet Pipe • Always contains water • Can freeze in cold weather • Most commonly used • Dry Pipe • Water not in pipe • Released after delay • Allows system shut down before water release
Water Pipes (contd) • Pre-action systems • Water released after a sprinkler head is melted • Deluge system • Sprinkler head is open • Releases a lot of water fast
Extinguishers • Placed within 50 feet of electrical equipment • Inspected four times a year • Clearly marked • Easily reached • Filled with appropriate reagents
Physical Intrusion Detection • Electrical Circuits • Light Beams • Passive IR • Ultrasonic
Management Issues • Physical Security Audits • Drills • Internal Testing • Pen Testing • Maintenance Issues • Education and Training