A Matched Filter System for Muon Detection with Tilecal

IX International Workshop ACAT. A Matched Filter System for Muon Detection with Tilecal. R. R. Ramos 1 , J. M. de Seixas 2 and A. S. Cerqueira 3 1,2 Signal Processing Laboratory EP/COPPE – Federal University of Rio de Janeiro 3 Federal University of Juiz de Fora. Topics.

jmarston
Download Presentation

A Matched Filter System for Muon Detection with Tilecal

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. IX International Workshop ACAT A Matched Filter System for Muon Detection with Tilecal R. R. Ramos1, J. M. de Seixas2 and A. S. Cerqueira3 1,2 Signal Processing Laboratory EP/COPPE – Federal University of Rio de Janeiro 3 Federal University of Juiz de Fora

  2. Topics • The Hadronic Calorimeter (Tilecal) • The Muon Signal • The Matched Filter System • Results • Conclusions A Matched Filter System for Muon Detection with Tilecal

  3. The Hadronic Calorimeter (Tilecal) ATLAS • Tilecal is the hadronic calorimeter of ATLAS. • Tilecal comprises 192 modules. • Each module is segmented into three layers of cells. • The last layer may be used by the LVL1 trigger envisaging muon detection. Tilecal Barrel Extended Barrels A Matched Filter System for Muon Detection with Tilecal

  4. The Tilecal and the Muon Signal • Tilecal cells geometry: • The Level 1 trigger (LVL1) requiresanalogue signal summation along the three sampling layers (up to six calorimeter redout channels) of the calorimeter, forming the so called trigger tower signals. • Each adder circuit also fanouts the • information corresponding to the third layer of the calorimeter, which is used for muon detection. • As muons deposit very small energy levels in the calorimeter, muon output signal exhibits low signal-to-noise ratio. Tilecal layers: 1st - (A# cells) 2nd - (B#, C# cells) 3rd - (D# cells) Tilecal electronic readout: A Matched Filter System for Muon Detection with Tilecal

  5. The Muon Signal (1) • July, 2003 testbeam setup: Physics events (signal) Superposition • 16 samples/event (Fast ADC – 40MHz). • Muon signal severely corrupted by background noise. • Online detection is critical. • Adding the muon outputs corresponding to a given D_cell may improve the signal-to-noise ratio. • Projective data at η = 0.45 (D2 cell) was analysed. Mean Pedestal events (noise) ??? Superposition Mean • FADC problems. Only 14 samples were considered in analysis. A Matched Filter System for Muon Detection with Tilecal

  6. The Muon Signal (2) • Discriminating signal from noise: Peak sample histograms • An usual technique consists of a simple peak detector. • An efficiency above 88.0% is obtained for a false alarm probability of 10.0%, considering the summation of the two signals of the same D_cell. • Using a single muon output results in an efficiency higher than 70.0% for the same 10.0% false alarm probability. • Adding the two signals improves the detection efficiency and is considered in the matched filter system development. Receiver Operating Characteristic (ROC) A Matched Filter System for Muon Detection with Tilecal

  7. The Matched Filter System (1) • The detection problem can be modeled as the classical decision rule between two hypothesis, where n[k] is considered a zero-mean additive white gaussian noise with variance N0/2 and s[k] is the signal to be detected. H1: r[k] = s[k] + n[k] , k = 1,…,K H0: r[k] = n[k] • We make use of the orthonormal expansion of s[k], the well-known Karhunen-Löeve Series. Considering Ks the auto-correlation matrix of s[k], we have Ks.Q = Q.λ, Ks = E[s.sT] Q – matrix of orthonormal eigenvectors qi λ – matrix of diagonal eigenvalues λi A = QT.s , A – 1,…,Kprojections • Using the new orthonormal basis spanned by Q, the signal sM[k] can be reconstructed by truncating the series in the M-ary term. sM[k] = Q.A , A – 1,…,M projections Q – 1,…,M eigenvectors or principal components (PCAs) A Matched Filter System for Muon Detection with Tilecal

  8. The Matched Filter System (2) • Both signal s[k] and noise n[k] processes are considered multivariate Gaussians so that the classical matched filtering algorithm for random processes can be adapted to this problem. • Instead of using the signal s[k] (not available), we use r[k] under the hypothesis H1. The algorithm is derived by computing the following likelihood ratio: • The detection is made by comparing this ratio result with a threshold η (Neyman-Pearson rule). • We can take the natural logarithm of the likelihood ratio, resulting in an optimal receiver The Øi are the eigenvectors qi. M = 14. K = 1,…,14. A Matched Filter System for Muon Detection with Tilecal

  9. Results (1) • The covariance matrix Kn of the background noise n[k] shows that it´s not white. Kn before whitening filter • The matched filter is considered optimal in the sense of the signal-to-noise ratio if the signal to be matched is corrupted by white noise. Kn after whitening filter (training set) • At this point, a whitening filter for proper treatment of the background noise is necessary. • That is made by an orthogonal transformation equivalent to the following Kn after whitening filter (testing set) (similarity transformation) A Matched Filter System for Muon Detection with Tilecal

  10. Results (2) ROCs with whitening filter • The development of the matched filter is normally performed considering the new signal r*[k] (after whitening). • The overall performance of the detector grows as we decrease the number of PCAs in both cases (with or without whitening filter). ROCs without whitening filter • The efficiency with the whitening filter is better, reaching 93.5%, when compared to peak detector (89.0%), for a fixed 10.0% false alarm probability. A Matched Filter System for Muon Detection with Tilecal

  11. Results (3) • We considered a deterministic approach by designing a matched filter that uses the mean signal of hypothesis H1 (muon signal) as the signal to be matched. Overall Performance Comparison • At this point, we have three approaches to be compared: the peak detector, and both stochastic and deterministic matched filters. • The stochastic matched filter has the best performance of the three approaches. A Matched Filter System for Muon Detection with Tilecal

  12. Conclusions • We developed a matched filter system that reached an efficiency of 93.5% (for 10.0% false alarm probability). A whitening filter was also designed as part of the system. • The matched filter system using whitening filter outperforms a peak detector based system that is being considered by the Tilecal collaboration. • The development of an online system is being considered to be part of the ATLAS experiment. • The use of neural networks is also being considered. Preliminary results are promising. A Matched Filter System for Muon Detection with Tilecal