An improved matched filter for blood vessel detection of digital retinal images

An improved matched filter for blood vessel detection of digital retinal images. Source: Computers in Biology and Medicine (2007) pp. 262 – 267 Authors: Mohammed Al-Rawi, Munib Qutaishat, and Mohammed Arrar Impact factor: 1.068 (2006) Reporter: Kai Hung Chen Date: Mar 11, 2008. Outline.

wind
Download Presentation

An improved matched filter for blood vessel detection of digital retinal images

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. An improved matched filter for blood vessel detection of digital retinal images Source: Computers in Biology and Medicine (2007) pp. 262 – 267 Authors: Mohammed Al-Rawi, Munib Qutaishat, and Mohammed Arrar Impact factor: 1.068 (2006) Reporter: Kai Hung Chen Date: Mar 11, 2008

  2. Outline • Introduction • Proposed method • Experiment results

  3. Introduction • : The green band of a digital retina image • : The profile of a one pixel width at the 200th row of the retina image shown in (a)

  4. ProposedMethod L: the length of the vessel segment that has the same orientation σ: the spread of the intensity profile

  5. ProposedMethod Neighborhood N is defined as: The pointPithat belongs to N is:

  6. ProposedMethod The corresponding weights in the kernel i ( i =1, . . . , 12 which is the number of kernels) are given by: The filter is normalized as:

  7. Quality Factor • True pixels: pixels detected as vessels and they appear as vessels in the hand label image. • False pixels: pixels detected as vessels yet they appear as non-vessels in the hand labeled image. • true_ratio: divide the true pixels by the number of vessel pixels in the hand labeled image. • false_ratio: divide the false pixels by the number of non-vessel pixels in the hand labeled image. • Quality Factor ( QLσT )= true_ratio − false_ratio

  8. ExperimentResults

  9. ExperimentResults

  10. ExperimentResults MAA: maximum accuracy average, the average accuracy of all images.

  11. ExperimentResults

  12. ExperimentResults

  13. ExperimentResults

  14. Experiment Results