An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Dozer: Sensors Calibration and Hydraulic Calibration

  2. Pitch Sensor Location • Mount the sensor on the blade • Allow the sensor to rotate 90 degrees for tilt calibration • In this graphic it is positioned in the normal operating position

  3. Pitch Sensor Calibration • Required if AS400 is permanently installed on the machine to measure blade pitch • Park machine on level ground • Make sure the left mast is vertical (if possible) in the forward/aft direction • If it is not possible to make the left mast vertical, put the machine and blade in the normal working position • Press “Calibrate” to zero the pitch sensor.

  4. Pitch Sensor Calibration

  5. Pitch Sensor Calibration

  6. Valve Calibration - Basics • Allows smooth automatic control • GCS900 monitors the valve movement and computes a response curve. • Can be done with and without GPS /ATS • Before starting the valve calibration you need to ensure that the machine measurements are entered into the CB430 • The valve calibration should be done with warm oil and at normal operating revs.

  7. Lift Calibration • Must be in Manager mode • Setup / Installation Menu / Valve Calibration • Select “Lift” • A set of screens follow – perform the instructions

  8. Calibration without GPS/ATS • The following screens appear if the GPS/ATS sensors are not detected or due to a low accuracy condition

  9. Calibration without GPS/ATS

  10. Calibration without GPS/ATS

  11. Calibration without GPS/ATS

  12. Calibration with GPS/ATS • Similar screens to previous method without the requirement to measure blade height differences (GPS/ATS does this for you!)

  13. Calibration with GPS/ATS

  14. Calibration with GPS/ATS

  15. Calibration with GPS/ATS

  16. Calibration with GPS/ATS

  17. Calibration with GPS/ATS

  18. Lift Calibration • Place in Auto • Press the Auto/Manual switch • System will then automatically move the blade and monitor the movement against the valve command

  19. Lift Calibration

  20. Lift Calibration

  21. Lift Calibration

  22. Tilt Calibration • Process is similar to the lift calibration • Tilt Calibration requires the AS400 sensor to be rotated 90 degrees to measure the blade tilt

  23. Tilt Calibration

  24. Tilt Calibration

  25. Tilt Calibration

  26. Tilt Calibration

  27. Tilt Calibration

  28. Questions?