Taylor University HENA CDR July 9 &10 1997. Science Specification Table. 12 keV - 250 keV for neutral particles 40.5 cm 2 image plane Electronic Noise 3 keV FWHM Proton Dead Layer <3 keV Focal Length 6.16 to 6.95 cm FOV 40 degrees Pixel size 4 x 4 mm

juliet
Download Presentation

Science Specification Table

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Taylor University HENA CDR July 9 &10 1997 Science Specification Table • 12 keV - 250 keV for neutral particles • 40.5 cm2 image plane • Electronic Noise 3 keV FWHM • Proton Dead Layer <3 keV • Focal Length 6.16 to 6.95 cm • FOV 40 degrees • Pixel size 4 x 4 mm • 256 Energy Levels (10 Bit A/D)

  2. Taylor University HENA CDR July 9 & 10 1997 Engineering Specification Table • Sensors: XY Position Si solid state sensors • Two vendors used: Micron and Canberra • Analog Electronics 250 A225 preamplifiers 16 ASIC amplifiers • ? Total Power 3 Watts (at supply voltages) • Voltages +/-3.5, +/-5, and bias voltage (-70V) • Planned Temperature Operation 10o C +- 20o C • Survival Temperature: +60oC, -50oC • ? Mass 3.53 kg (estimated) • ? Dimensions 7.62 x 22.35 x 24.13 cm

  3. Taylor University HENA CDR July 9 & 10 1997 SENSOR SPECIFICATIONS • MEASURES NEUTRALS E>12 keV • 4 - 60 ELEMENT ARRAY (12 X 5) • ACTIVE AREA: 48.7mm x 20.8mm per SSD • THICKNESS: >200 MICRONS • THIN WINDOW: <5keV H+ ENERGY LOSS (Si) • BIAS APPLIED TO THIN WINDOW SIDE OPPOSITE PIXELS • LEAKAGE CURENT: <10nA • ELECTRONIC NOISE RESOLUTION: <1KeV FWHM • BOND PADS: 4 - 5 MILS • BOND WIRES: < 1.25 MILS

  4. Taylor University HENA CDR July 9 & 10 1997 SSD Design Features • Parallel processing (240 channels) • High resolution (240 pixel array @ 256 Energy levels) • Low Power • Single Box Assembly

  5. Taylor University HENA CDR July 9 & 10 1997 System Design

  6. Taylor University HENA CDR July 9 & 10 1997 Weight Breakdown • Middle Box .93 kg (cal.) • Radiation Shielding (outside walls = .23 in.) .7 kg (est.) • ? 240 A225 Preamps (SIP package) ? .94 kg (mes.) • 16 ASICs .12 kg (mes.) • 4 PC Board and MDM connectors .24 kg (cal.) • SSD Assembly .15 kg (cal.) • Processing Boards .21 kg (cal.) • Misc parts (screws, connectors) .2 kg (est.) Total 3.13 kg

  7. Taylor University HENA CDR July 9 & 10 1997 Design Philosophy • Use Existing Technology • Use Well Proven Analog Gate Array Technology • High reliability, Parallel Processing, Low Power, and Low Complexity • Rigorous Testing and Burn-In of Subsystems • State-of-the-Art Instrument

  8. Taylor University HENA CDR July 9 & 10 1997 SSD Sensor Heritage Images from SEPS (HENA has similar SSD design) • SSD Sensors • SEPS (Source Loss/Cone Energetic Particle Spectrometer flew in the winter of 95’. It’s mission was to study energetic electrons, ions, and neutrals in the source loss cone. • IPS (Imaging Proton Spectrometer)

  9. Taylor University HENA CDR July 9 & 10 1997 FEA Microcircuit Heritage POLAR Satellite • FEA Micro circuits • POLAR Satellite • SEPS • IPS • PIXIE (Polar Ionospheric X-Ray Imaging Experiment) • SPADUS (flew on the Argos satellite) • MAXIE (Magnetospheric Atmosphere X-Ray Imaging Experiment) flew on Aug. 9, 1993 on the TIROS satellite. It measured x-rays in the range of 4 - 100 keV. SEPS SPADUS

  10. Taylor University HENA CDR July 9 & 10 1997 HENA Middle Box Cross Section

  11. Taylor University HENA CDR July 9 & 10 1997 HENA Middle Box Design

  12. Taylor University HENA CDR July 9 & 10 1997 Middle Box Assembly Renderings SSD Assembly SSD MCP Shield SSD Mount DPU Connection

  13. Taylor University HENA CDR July 9 & 10 1997 ?Middle Box Mass Properties

  14. Taylor University HENA CDR July 9 & 10 1997 Preamplifier Board Design

  15. Taylor University HENA CDR July 9 & 10 1997 Preamplifier Board Rendering Flex Cable Connection 60 A225 Preamps 4 FEA Chips Actel Chip MDM Connector

  16. Taylor University HENA CDR July 9 & 10 1997 A225 Preamp Response Curve

  17. Taylor University HENA CDR July 9 & 10 1997 A225 Preamp Testing Continued

  18. Taylor University HENA CDR July 9 & 10 1997 SSD Mounting Assembly

  19. Taylor University HENA CDR July 9 & 10 1997 Detector Geometry

  20. Taylor University HENA CDR July 9 & 10 1997 Pixel Angular Resolution from Center of Pin Hole

  21. Taylor University HENA CDR July 9 & 10 1997 Angle Limit Diversity Over Detector Surface Per Pixel

  22. Taylor University HENA CDR July 9 & 10 1997 Resolution of SSD w/ Increasing Pixels

  23. Taylor University HENA CDR July 9 & 10 1997 SSD Cap., Noise, Thickness

  24. Taylor University HENA CDR July 9 & 10 1997 Vendor Response List Name of Vendor Response • Canberra Detailed Proposal and Price Schedule for Detector • Micron Detailed Proposal (more costly) under iteration • UDT Sensors Interested (no proposal yet) • Hamamatsu Interested (no proposal yet) • Spectrum Sciences Very interested (Proposal in by Dec. 11)

  25. Taylor University HENA CDR July 9 & 10 1997 Procurement Schedule • OCT. 96’ • RECEIVED 2 PROPOSALS FOR PROTOTYPE AND FLIGHT SENSORS • DEC. 96’ • OBTAIN UPFRONT FUNDING FOR MASK DESIGN • JAN 97’ • PURCHASE PROTOTYPE TO NEAR FLIGHT SPECIFICATIONS • RIGOROUSLY TEST PROTOTYPE • March 97’ • ORDER FLIGHT SENSORS • Jan 98’ • OBTAIN FLIGHT SENSORS 4-6 MONTHS FROM ORDER

  26. Taylor University HENA CDR July 9 & 10 1997 SSD Detector Holder Rendering Metalized PC Card SSD Shields Platform

  27. Taylor University HENA CDR July 9 & 10 1997 PC Card for SSD Design

More Related