An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Etap 4 Etap 12 Etap 13 Etap 17 Etap 18 UDOSKONALENIE WYSOKOCZUŁEJ STACJI POMIAROWEJ DO REJESTRACJI PROMIENIOWANIA NEUTRONOWEGO I GAMMA Stanisław Pszona

  2. Aktualnie prowadzone prace Zestawienie i przeprowadzenie badań modelu stacji pomiarowej celem ustalenia jej charakterystyk: funkcjonalnej i odpowiedzi dla promieniowania gamma i neutronów

  3. Monitor – aktualny stan

  4. Układ detekcyjny • Cross section of measuring device. • PE – 203mm polythene moderator. • 160kPa He PC – 160kPa Helium-3 proportional counter

  5. 6000 E Q E P 5000 E H 4000 E E H P E P E H 3000 Counts per channel 2000 E E P H 1000 0 0 200 400 600 800 1000 Channels, 1 keV per channel Idealized pulse – height spectrum of a 3He proportional counter irradiated by thermal neutrons

  6. 160kPa proportional counter pulse height spectrum . Counter in 203mm dia PE sphere irradiated by Cf source.

  7. Widmo impulsów - gamma

  8. Widmo impulsów - n + γ

  9. A pulse height spectra from a bare160 kPa He proportional counter:blue squares - natural radiation environment; pink dots - Asse salt mine

  10. Response to gamma Relative response of a 160 kPa 3He proportional counter in a 203 mm polythene sphere as a function of photon energy. Horizontal lines indicate ±30% deviations. Result of the calculations.

  11. Summary of calibration

  12. Pomiar tła n+γ w pom.86 (bud.2) Obszar kolorowy – pomiary ze źródłem neutronowym w hali kalibracyjnej (odległość ok. 25m)

  13. Pomiar tła n+γ w pom.86 (bud.2)

  14. Plan dalszych prac • Opracowanie części detekcyjnej prototypu (demonstratora) stacji pomiarowej (w tym optymalizacja detektora i moderatora stacji pomiarowej • Opracowanie części rejestrującej demonstratora (mikroprocesorowego systemu spektrometrycznej akwizycji danych, w programowalnych cyklach pomiarowych z autonomiczną pamięcią statyczną). • Przeprowadzeniu testów zoptymalizowanego detektora jak i układu rejestracji i analizy danych pomiarowych (jako demonstratora) w warunkach laboratoryjnych jak i terenowych. • Udział w pomiarach porównawczych z innymi metodami pomiaru tła w wybranej lokalizacji EJ. • Opracowanie dokumentacji pomiarowej i wykonawczej demonstratora

  15. Dziękuję za uwagę