280 likes | 463 Views
Perimeter Intruder Detection System. Sensing Junction Box and Terminal Junction Box Installation Manual. Junction Boxes Installation Manual. Nxtar Technologies, INC. 51 Hwangong Rd, YungKang Industrial Park, Tainan 710, Taiwan Tel: +886 6 3015911 Fax: +886 6 3015912
E N D
Perimeter Intruder Detection System Sensing Junction Box and Terminal Junction Box Installation Manual Junction Boxes Installation Manual Nxtar Technologies, INC. 51 Hwangong Rd, YungKang Industrial Park, Tainan 710, Taiwan Tel: +886 6 3015911 Fax: +886 6 3015912 Website: www.nxtar.com
Perimeter Intruder Detection System INTRODUCTION All Nxtar’s Junction Boxes are made of ABS + Polycarbonate material to withstand the harshest outdoor conditions and to meet the customer’s requirements. Using our plug and play design, there is no need for expensive splicer and fusing during installation which saves installation cost and time. In this manual we illustrate the connections from the Leading Fiber to the Sensing Junction Box, and from the Sensing Fiber to their respective Terminal Junction Boxes. From the step-by-step instructions, the SI or Authorized Installer should be able to perform all the installation for the outfield components. Junction Boxes Installation Manual 2 Nxtar Technologies, INC. 51 Hwangong Rd, YungKang Industrial Park, Tainan 710, Taiwan Tel: +886 6 3015911 Fax: +886 6 3015912 Website: www.nxtar.com
Sensing Junction Box Terminal Box Sensing Fiber Leading Fiber 99% Alcohol Electric Screwdriver 27 mm Spanner Perimeter Intruder Detection System JUNCTION BOX INSTALLATION TOOLS 1. Components supplied by Nxtar Waterproof sticky tape Junction Boxes Installation Manual 2. Tools prepared by installer 3M Kim swipes 3 Nxtar Technologies, INC. 51 Hwangong Rd, YungKang Industrial Park, Tainan 710, Taiwan Tel: +886 6 3015911 Fax: +886 6 3015912 Website: www.nxtar.com
Perimeter Intruder Detection System SENSING JUNCTION BOX INSTALLATION Step1.Insert a fiber into the port labeled “SF1”. Extra care needs to be taken when inserting the connectors. Never bend the fibers at s harp angels. Sensing Fiber 1 Core Junction Boxes Installation Manual Step2.Place branch head in the middle as shown below. Push fiber forward carefully, do not pull branch head lest the fiber is broken when you are pulling. Branch head is located at red point 4 Nxtar Technologies, INC. 51 Hwangong Rd, YungKang Industrial Park, Tainan 710, Taiwan Tel: +886 6 3015911 Fax: +886 6 3015912 Website: www.nxtar.com
Perimeter Intruder Detection System SENSING JUNCTION BOX INSTALLATION Step3.Remove the cap of the “SF1” adaptor and prepare for connections. Junction Boxes Installation Manual Step 4.Remove the cap of connector (see the picture below). 5 Nxtar Technologies, INC. 51 Hwangong Rd, YungKang Industrial Park, Tainan 710, Taiwan Tel: +886 6 3015911 Fax: +886 6 3015912 Website: www.nxtar.com
Perimeter Intruder Detection System SENSING JUNCTION BOX INSTALLATION Step5.Connect the connectors “SF1” as follows. The fiber must be tucked gently into the box, no fragments of the fiber should be protruding out of the box. Connector head should not touch any surface or the hands of the installer. Junction Boxes Installation Manual Step6.The fiber and cladding plastic are required to be cleaned by alcohol. Wrap sealed tape around the thread head about 2~3 loops(tape length is about 15cm). Use 27mm spanner to tighten the cap in clockwise. 6 Nxtar Technologies, INC. 51 Hwangong Rd, YungKang Industrial Park, Tainan 710, Taiwan Tel: +886 6 3015911 Fax: +886 6 3015912 Website: www.nxtar.com
Perimeter Intruder Detection System SENSING JUNCTION BOX INSTALLATION Step7.No fragment of fiber should be protruding out of the box. Fiber in the right position Junction Boxes Installation Manual Step8.Insert a fiber into the port labeled “SF2”. Extra care needs to be taken when inserting the connectors. Never bend the fibers at sharp angels. Sensing Fiber 1 Core 7 Nxtar Technologies, INC. 51 Hwangong Rd, YungKang Industrial Park, Tainan 710, Taiwan Tel: +886 6 3015911 Fax: +886 6 3015912 Website: www.nxtar.com
Perimeter Intruder Detection System SENSING JUNCTION BOX INSTALLATION Step9.Place branch head in the middle as shown below. Push fiber forward carefully, do not pull branch head lest the fiber is broken when you are pulling. Junction Boxes Installation Manual Step10.Remove the cap of the “SF2” adaptor and prepare for connections. Brach head is located at green point 8 Nxtar Technologies, INC. 51 Hwangong Rd, YungKang Industrial Park, Tainan 710, Taiwan Tel: +886 6 3015911 Fax: +886 6 3015912 Website: www.nxtar.com
Perimeter Intruder Detection System SENSING JUNCTION BOX INSTALLATION Step11.Remove the cap of connector (see the pictures below). Junction Boxes Installation Manual Step12.Connect the connectors “SF2” as follows. Both fibers must be tucked gently into the box, no fragment of any fiber should be protruding out of the box. Connector head should not touch any surface or the hands of the installer. 9 Nxtar Technologies, INC. 51 Hwangong Rd, YungKang Industrial Park, Tainan 710, Taiwan Tel: +886 6 3015911 Fax: +886 6 3015912 Website: www.nxtar.com
Perimeter Intruder Detection System SENSING JUNCTION BOX INSTALLATION Step13.The fiber and cladding plastic are required to be cleaned by alcohol. Wrap sealed tape around the thread head about 2~3 l oops(tape length is about 15cm). Use 27mm spanner to tighten the cap in clockwise. Junction Boxes Installation Manual Step14.No fragment of any fiber should be protruding out of the box. Fiber is in the right position 10 Nxtar Technologies, INC. 51 Hwangong Rd, YungKang Industrial Park, Tainan 710, Taiwan Tel: +886 6 3015911 Fax: +886 6 3015912 Website: www.nxtar.com
Perimeter Intruder Detection System SENSING JUNCTION BOX INSTALLATION Step15.Insert a fiber into the port labeled “LF”. Extra care needs to be taken when inserting the connectors. Never bend the fibers at sharp angels. Leading Fiber 2 Core Junction Boxes Installation Manual Step16.Place branch head in the middle as shown below. Push fiber forward carefully, do not pull branch head lest the fiber is broken when you are pulling. Branch head is located at yellow point 11 Nxtar Technologies, INC. 51 Hwangong Rd, YungKang Industrial Park, Tainan 710, Taiwan Tel: +886 6 3015911 Fax: +886 6 3015912 Website: www.nxtar.com
Perimeter Intruder Detection System SENSING JUNCTION BOX INSTALLATION Step17.Remove the cap of the “LF” adaptor and prepare for connections. Junction Boxes Installation Manual Step18.Remove the caps of the connectors (see picture below). 12 Nxtar Technologies, INC. 51 Hwangong Rd, YungKang Industrial Park, Tainan 710, Taiwan Tel: +886 6 3015911 Fax: +886 6 3015912 Website: www.nxtar.com
Perimeter Intruder Detection System SENSING JUNCTION BOX INSTALLATION Step19.Connect the connectors “LF” as follows. The fiber must be tucked gently into the box, no fragment of fiber should be protruding out of the box. Connector head should not touch any surface or the hands of the installer. Junction Boxes Installation Manual Step20.The fiber and cladding plastic are required to be cleaned by alcohol. Wrap sealed tape around the thread head about 2~3 loops(tape length is about 15cm). Use 27mm spanner to tighten the cap in clockwise. 12 Nxtar Technologies, INC. 51 Hwangong Rd, YungKang Industrial Park, Tainan 710, Taiwan Tel: +886 6 3015911 Fax: +886 6 3015912 Website: www.nxtar.com
Perimeter Intruder Detection System SENSING JUNCTION BOX INSTALLATION Step21.No fragment of fibers should be protruding out of the box. Fiber is in the right position Junction Boxes Installation Manual Step22.Clean o-ring of the box and seal of upper cover. Cover it finally. 13 Nxtar Technologies, INC. 51 Hwangong Rd, YungKang Industrial Park, Tainan 710, Taiwan Tel: +886 6 3015911 Fax: +886 6 3015912 Website: www.nxtar.com
5 4 8 1 2 7 3 6 Perimeter Intruder Detection System SENSING JUNCTION BOX INSTALLATION Step23.Tightened the cover with a screw driver or electric screwdriver in the sequence as shown. Junction Boxes Installation Manual Step24.Take out water resistant tape for next step. 14 Nxtar Technologies, INC. 51 Hwangong Rd, YungKang Industrial Park, Tainan 710, Taiwan Tel: +886 6 3015911 Fax: +886 6 3015912 Website: www.nxtar.com
Original Width Original Width 2/3 of width Overlapped. Width after Stretching Perimeter Intruder Detection System SENSING JUNCTION BOX INSTALLATION Step25.Wrap from bottom of cap and it stretches 2/3 width as original. Junction Boxes Installation Manual Step26.Entwine thecap and fiber with tape. Overlapping entwine is needed at 2/3 width of the tape. (See pictures below) 15 Nxtar Technologies, INC. 51 Hwangong Rd, YungKang Industrial Park, Tainan 710, Taiwan Tel: +886 6 3015911 Fax: +886 6 3015912 Website: www.nxtar.com
Perimeter Intruder Detection System SENSING JUNCTION BOX INSTALLATION Step27.Keep tape and fiber clean. Notice whether dust is on the fiber or not . Junction Boxes Installation Manual Step28.After entwining, the tail of tape must be tightened with the fiber. Make sure the joint is complete tight. Extra care needs to be taken when pressing the fiber. Never bend the fibers at sharp angels. 16 Nxtar Technologies, INC. 51 Hwangong Rd, YungKang Industrial Park, Tainan 710, Taiwan Tel: +886 6 3015911 Fax: +886 6 3015912 Website: www.nxtar.com
Perimeter Intruder Detection System SENSING JUNCTION BOX INSTALLATION Step29.Tape other caps in the similar manner Junction Boxes Installation Manual 17 Nxtar Technologies, INC. 51 Hwangong Rd, YungKang Industrial Park, Tainan 710, Taiwan Tel: +886 6 3015911 Fax: +886 6 3015912 Website: www.nxtar.com
Perimeter Intruder Detection System TEMINAL JUNCTION BOX Step1.Insert a fiber into the port. Extra care needs to be taken when inserting the connectors. Never bend the fibers at sharp angels. Junction Boxes Installation Manual Step2.Place branch head in the middle as shown below. Push fiber forward carefully, do not pull branch head lest the fiber is broken when you are pulling. Branch head location 18 Nxtar Technologies, INC. 51 Hwangong Rd, YungKang Industrial Park, Tainan 710, Taiwan Tel: +886 6 3015911 Fax: +886 6 3015912 Website: www.nxtar.com
Perimeter Intruder Detection System TEMINAL JUNCTION BOX Step3.Remove the cap of Adaptor Enlarged Junction Boxes Installation Manual Step4.Remove the cap of connector (see the picture below). 19 Nxtar Technologies, INC. 51 Hwangong Rd, YungKang Industrial Park, Tainan 710, Taiwan Tel: +886 6 3015911 Fax: +886 6 3015912 Website: www.nxtar.com
Perimeter Intruder Detection System TEMINAL JUNCTION BOX Step5.Connect the connectors as follows. The fiber must be tucked gently into the box, no fragment of fiber should be protruding out of the box. Connector head should not touch any surface or the hands of the installer. Junction Boxes Installation Manual Step6.The fiber and cladding plastic are required to be cleaned by alcohol. Wrap sealed tape around the thread head about 2~3 loops(tape length is about 15cm). Use 27mm spanner to tighten the cap in clockwise. 20 Nxtar Technologies, INC. 51 Hwangong Rd, YungKang Industrial Park, Tainan 710, Taiwan Tel: +886 6 3015911 Fax: +886 6 3015912 Website: www.nxtar.com
Perimeter Intruder Detection System TEMINAL JUNCTION BOX Step7.No fibers should be protruding out of the box. Junction Boxes Installation Manual Fiber is in the right position Step8.Clean o-ring of the box and joint of upper cover. Cover it finally. 21 Nxtar Technologies, INC. 51 Hwangong Rd, YungKang Industrial Park, Tainan 710, Taiwan Tel: +886 6 3015911 Fax: +886 6 3015912 Website: www.nxtar.com
3 1 5 6 2 4 Perimeter Intruder Detection System TEMINAL JUNCTION BOX Junction Boxes Installation Manual Step9.Tightened the cover with a screw driver or electric screwdriver in the sequence as shown. Check whether the box is seamless. Step10.Take out water resistant tape for next step. 22 Nxtar Technologies, INC. 51 Hwangong Rd, YungKang Industrial Park, Tainan 710, Taiwan Tel: +886 6 3015911 Fax: +886 6 3015912 Website: www.nxtar.com
Perimeter Intruder Detection System TEMINAL JUNCTION BOX Junction Boxes Installation Manual Step12.Entwine thecap and fiber with tape. Overlapping entwine is needed at 2/3 width of the tape. (See pictures below) Step11.Wrap from bottom of cap and it stretches 2/3 width as original. Original Width Original Width Width after Stretching 2/3 of width Overlapped. 23 Nxtar Technologies, INC. 51 Hwangong Rd, YungKang Industrial Park, Tainan 710, Taiwan Tel: +886 6 3015911 Fax: +886 6 3015912 Website: www.nxtar.com
Perimeter Intruder Detection System TEMINAL JUNCTION BOX Step13.Keep tape and fiber clean. Notice whether dust is on the fiber or not . Junction Boxes Installation Manual Step14.After entwining, the tail of tape must be tightened with the fiber. Make sure the joint is complete tight. Extra care needs to be taken when pressing the fiber. Never bend the fibers at sharp angels. 24 Nxtar Technologies, INC. 51 Hwangong Rd, YungKang Industrial Park, Tainan 710, Taiwan Tel: +886 6 3015911 Fax: +886 6 3015912 Website: www.nxtar.com
Perimeter Intruder Detection System TEMINAL JUNCTION BOX Step15.Completed the assembly. Junction Boxes Installation Manual 25 Nxtar Technologies, INC. 51 Hwangong Rd, YungKang Industrial Park, Tainan 710, Taiwan Tel: +886 6 3015911 Fax: +886 6 3015912 Website: www.nxtar.com
Perimeter Intruder Detection System Junction Box Installation Cleaning Of Connectors Junction Boxes Installation Manual Use only Kimtech Science KIMWIPES (or similar) And 99% Alcohol to clean all Connectors. Apply the alcohol onto the Kimwipes and clean the SC/ APC connectors thoroughly. Take note as not to touch the wet part of the Kimwipes with your hand 26 Nxtar Technologies, INC. 51 Hwangong Rd, YungKang Industrial Park, Tainan 710, Taiwan Tel: +886 6 3015911 Fax: +886 6 3015912 Website: www.nxtar.com
Perimeter Intruder Detection System DIMENSION NOTE Junction Boxes Installation Manual For more information on using the Nxtar P.I.D.S. NS series products with buried underground application, please contact our Technical Support Team directly at +886 6 3015911 Ext 202, or by email to hml@nxtar.com Nxtar Technologies, INC. 51 Hwangong Rd, YungKang Industrial Park, Tainan 710, Taiwan Tel: +886 6 3015911 Fax: +886 6 3015912 Website: www.nxtar.com