1 / 12

Be Off The Grid com Inc. LED TUBE LIGHTING

Be Off The Grid com Inc. LED TUBE LIGHTING. Replaces existing fluorescent lighting SAVING 70% IN ENERGY COST. 8W LED (2 foot) Size: 26mm(diameter)x602mm(length) LED quantity: 120pcs super bright SMD LEDs Lumen output: 700-800lumens 18W LED (4 foot) Size: 26mm(diameter)x1212mm(length)

kaden
Download Presentation

Be Off The Grid com Inc. LED TUBE LIGHTING

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Be Off The Grid com Inc. LED TUBE LIGHTING

  2. Replaces existing fluorescent lighting SAVING 70% IN ENERGY COST • 8W LED (2 foot) • Size: 26mm(diameter)x602mm(length) • LED quantity: 120pcs super bright SMD LEDs • Lumen output: 700-800lumens • 18W LED (4 foot) • Size: 26mm(diameter)x1212mm(length) • LED quantity: 288pcs super bright SMD LEDs • Lumen output: 1400-1600lumens • 20W LED (5 foot) • Size: 26mm(diameter)x1512mm(length) • LED quantity: 360pcs super bright SMD LEDs • Lumen output: 1800-2000lumens

  3. Improvements • Using different constant current IC which makes the products even more reliable we have reached our 3rd Generation of LED Tube Products. • After the modification, the PF value of the new product will come up to more than 0.95 (was around 0.90 and most other LED Tube Lights are .80). • More reasonable components on PCB makes the heat come out more easier. • We use the same design for AC110V and AC277V. All the PCB layout will be the same, if your customer need AC277V, we will modify some components on the AC110V tube, and it will work well on AC277V situation.

  4. LED Tube Lighting • Environmental Protection • Rapid start, no frequency; • No Ultra Violet or Infra Red light radiation, comfortable, no noise. • High-efficiency, low power consumption, produce very little heat; • Super energy-saving, super strong and safe, free maintenance; • No mercury and other hazardous material, fully RoHS-compliance; • Super long life time: minimum 4 years. • CE and RoHS Certification • LED tube light without dazzle light • Working voltage: • AC220-240V, 50-60Hz - AC110-130V, 50-60Hz • AC277 (now available)

  5. LED Tube Lighting SAVES • ENERGY • 70% Less cost to operate than conventional Fluoroscopic Tube lights over the life of the LED tube light. • Long Life Expectance (>50,000 Hrs) saves on maintenance and replacement cost. NO BALLASTS or STARTERS required • ENVIORNMENT • No mercury and other hazardous material, fully RoHS-compliance • BOOKS and DOCUMENTS (Libraries – Museums – Universities - Collections) • Light provides energy to fuel the chemical reactions that produce deterioration. Ultraviolet (UV) light is destructive, our LED Tube Lights emit ZERO UV light.

  6. Three Color Options • Warm White • 1400lumens • Natural White • 1600 lumens • Daylight White • 1800lumens Natural White Daylight White

  7. SMD LED Tube Lighting • Super bright SMD LEDs as light source, one LED is around 7lumens; • Special-treated frosted cover makes the LEDs inside the tubes invisible and without any dazzle light, the light output looks the same as normal fluorescent tube light without any light spot • One of the most well designed end cap with the strongest pins • PF value of this tube is around 0.95 (The products from most other manufacturers are less than 0.80)  • Can save as much as 70% of your energy cost over traditionalfluorescent bulbs when considering the elimination for ballast and starters • Life expectancy >50,000 Hours • 5 Yr Manufacturer Warrantee  • Aluminum back with frosted PC cover

  8. Actual Installation

  9. FIXTURE MODIFICATION FOR LED T8 TUBE LIGHT Magnetic Ballast Removal Traditional light fittings with magnetic ballast/inductive ballast: It is not necessary to remove the magnetic ballast/inductive ballast, only the starter needs to be removed from such fitting. While if you are able to remove also the magnetic ballast/inductive ballast, it will save you more energy. Original magnetic ballast/Inductive ballast: New correct LED T8 tube wiring:

  10. FIXTURE MODIFICATION FOR LED T8 TUBE LIGHTLight fittings with electronic ballast  Ballast compatibility  Electronic ballast are not compatible with LED T8 tube light, DO NOT install the LED T8 tube without moving/bypassing the electronic ballast as damage to the LED T8 tube light may occur.  Original electronic ballast: New correct LED T8 tube wiring: WRONG x

  11. Federal Funding Lighting Conservation Tax Incentives - $.60 Federal Tax Deduction per Square Foot! Our LED Tubes save a combined total of 75% or more, with a savings for both the Tube and the Ballast. An equivalent of 45% is saved, compared to standard Fluorescent lighting, with the LED Tubes alone. The Energy Policy Act of 2005 included a new tax incentive, to improve the energy efficiency of commercial buildings. The "Commercial Building Tax Deduction“ establishes a tax deduction for expenses incurred for energy efficient building expenditures made by a building owner. Buildings that save at least 50 percent of projected annual energy costs across all three system components are eligible for a tax deduction of $1.80 per square foot. Buildings that save a specified percentage of projected annual energy costs for one of the three components – building envelope (10 percent whole building energy savings), lighting (20 percent), or heating and cooling (20 percent) – are eligible for a $0.60 per square foot deduction. For lighting improvements that reduce lighting use by 25-40 percent and also employ dual switching (ability to switch roughly half the lights off and still have fairly uniform light distribution), the $0.60 per square foot may be prorated, ranging from $0.30 per square foot for 25 percent lighting energy savings to $0.60 per square foot for 40 percent savings. The Emergency Economic Stabilization Act of 2008 (HR-1424), approved and signed on October 3, 2008, Extends the benefits of the Energy Policy Act of 2005 through December 31, 2013. CONSULT YOUR TAX ADVISOR IF YOU QUALIFY

  12. Find State Incentives http://www.dsireusa.org Contact Us: Be Off The Grid com PO Box 256 1 Shawnee Church Road Shawnee on Delaware, PA 18356-0256info@beoffthegrid.comOffice: (908) 507-5809mike@beoffthegrid.com

More Related