High Power Test Facility - a joint ACIGA/LSC Project? ‘ Initial’ Report David McClelland, David Blair ACIGA LIGO-G010156-00-Z LSC Meeting, March 2001. Purpose: Preliminary list. Diagnose cavity operation, stability and dynamics at LIGO II circulating power (~ 1MW)

kaiser
Download Presentation

Purpose: Preliminary list

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. High Power Test Facility - a joint ACIGA/LSC Project? ‘Initial’ ReportDavid McClelland, David BlairACIGALIGO-G010156-00-ZLSC Meeting, March 2001.

  2. Purpose: Preliminary list • Diagnose cavity operation, stability and dynamics at LIGO II circulating power (~ 1MW) • Investigate thermal deformation and control in high power cavities • Investigate ‘cold’ lock up to full operating power, including changes to control and alignment signals

  3. Purpose (ctd) • field test a high power (>100 W) laser. • field test high power conditioned input optics • validate optical cavity modelling codes • integrate a high power laser system with a high power handling input optics system, a core optics system and a high power photo detection system.

  4. Status • ARC funding commenced January 2001 • LIGO commitment: core (2) and PR & MC optics • Completed • Central laboratory end stations at 80m • 5 vacuum chambers,160m vacuum pipe • Current • Outfitting optics laboratory • Installing vacuum envelope (to LII level) • Building isolation stacks

  5. Optical Design • Rationale • Should be as LIGOII like as possible • Input power, circulating power, spot sizes, cavity stability (g factors), cavity lengths • Allow results to apply to LIGOII • Directly • Simple scaling • Model validation

  6. ?Steps 1: Power Recycling Cavity ~ 2.1 kW PRC 125 W 150 W laser Sapphire optics, rear coated, r ~ 0.9975, thermal correction Fused silica optics, PRM thermal correction? Modecleaner length: 12-18 m PRC: length ~ 12 -15 m, near unstable, spot size ~ LII, PRF ~ 17.

  7. Main problems • PRC near unstable for both carrier and sidebands • ‘worst case scenario’?

  8. Output Modecleaner Step 2: Output modecleaner? ~ 2.1 kW PRC 125 W 150 W laser

  9. Steps 3: PR arm cavityprimary outcome for LII? 80m ~ 10m 125 W ~ 830 kW ~ 2.1 kW Staged: - 80 m stable cavity (g1 g2 ~ 0.3?) - add PR - BS may be used as ‘pick off’ monitor

  10. ~ 830 kW 80m ~ 2.1 kW PRC 125 W Output Modecleaner Option: PR Arm cavity Michelson

  11. PRC: length ~ 12 -15 m, near unstable, spot size ~ LII, PRF ~ 17. SRC, factor variable? Option: dual recycling? ~ 2.1 kW PRC 125 W Sapphire optics, rear coated, r ~ 0.9975, thermal correction Fused silica optics, PRM thermal correction?

  12. Output Modecleaner Option: dual recycling with OMC? ~ 2.1 kW PRC 125 W

  13. Proposal: • Establish the Gingin high power interferometer test facility (HPITFC) as an LSC Facility • Advisory board: • Reitze, U. Florida Blair, UWA • Zucker, MIT Munch, AU • Camp, Caltech (chair) McClelland, ANU • Willke, GEO • Sanders, Caltech • Chair? • Insert in LIGOII planning process

  14. Action: • Advisory group to meet at Amaldi • Brainstorm on : • short Michelson ? • PR Cavity but with what parameters? • PR arm cavity ? • Scheduling & Milestones?