1 / 23

Xe-CO 2 Stability Chiho Wang Duke University

Xe-CO 2 Stability Chiho Wang Duke University. Setup. X-ray aperture limits active region ~ 6-7cm on straw. 0.002” Cu foil reduced X-ray intensity to ~0.1uA/cm Only 1 pair of ASD sockets are active to draw current. Scan along straw at 8cm intervals.

Download Presentation

Xe-CO 2 Stability Chiho Wang Duke University

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Xe-CO2 Stability Chiho Wang Duke University

  2. Setup • X-ray aperture limits active region ~ 6-7cm on straw. • 0.002” Cu foil reduced X-ray intensity to ~0.1uA/cm • Only 1 pair of ASD sockets are active to draw current. • Scan along straw at 8cm intervals. • At each location, raise HV from 1550V to 1750V at 25V step, 20 sec interval. • Record current & # of Trips.

  3. Module 2.09 ASD #1

  4. Module 2.09 ASD #2

  5. Module 2.09, ASD #3

  6. Module 2.09, ASD #4

  7. Module 2.09, ASD #5

  8. Module 2.09, ASD #6

  9. Module 2.09, ASD #10

  10. Module 2.09, ASD #11

  11. Module 2.09, ASD #15

  12. Module 2.09, ASD #16

  13. Module 2.09, ASD #21

  14. Module 2.09, ASD #22

  15. Module 2.09, ASD #27

  16. Module 2.09, ASD #28

  17. Module 2.09, ASD #30

  18. Module 2.09, ASD #31

  19. Module 2.09, ASD #32

  20. Module 2.09, ASD #33

  21. Observation • Most ASD HV trip at mid wire support location. • Some ASD HV trip at end wire support. • After several hours of “burning” at the wire support, it gets more stable and less likely to trip • ASD 28-33 were scanned many times with Ar-CO2 before taking Xe data. They are obviously more stable. • In the case of Ar-CO2, X-ray also triggers a self-sustained current draw that lasts for several hours even after X-ray is turned off. This contributes to an increase of current draw when X-ray passes through mid wire support. This current, however, also dies out after burning.

  22. Module 2.09, ASD 30, Ar-CO2

  23. Summary • Xe-CO2 is stable at 1750V with 0.3uA/cm local rate • Mid wire support tends to be unstable in the beginning of the chamber operation, but can be improved with “burning”. • Some end wire supports also show the same instability but not as often as mid wire support.

More Related