1 / 23

High-Z target test at HiRadMat Proposal 1409

High-Z target test at HiRadMat Proposal 1409. C. Torregrosa, A. Perillo-Marcone, F . Loprete , M. Di Castro, D. Horvath, M. Calviani (EN/STI) With feedbacks from A. Lechner, S. Montesano (EN/STI). HiRadMat Scientific Board Meeting 14 th March 2014. Outline.

kalila
Download Presentation

High-Z target test at HiRadMat Proposal 1409

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. High-Z target test at HiRadMatProposal 1409 C. Torregrosa, A. Perillo-Marcone, F. Loprete, M. Di Castro, D. Horvath, M. Calviani (EN/STI) With feedbacks from A. Lechner, S. Montesano (EN/STI) HiRadMat Scientific Board Meeting 14th March 2014

  2. Outline M. Calviani - High-Z target test at HiRadMat - proposal 1409 • AD-target design and target R&D • Proposed HiRadMat tests • Beam requirements and experimental setup

  3. Introduction M. Calviani - High-Z target test at HiRadMat - proposal 1409 • Target material R&D: realization of a new target for the antiproton physics in the AD machine and for future CERN projects • Challenging regime in terms of strain rates and stresses • High-Z material mandatory for AD physics: iridium, tungsten and tungsten heavy alloys under consideration

  4. AD-target zone M. Calviani - High-Z target test at HiRadMat - proposal 1409 • Production of antiprotons for the AD physics • 26 GeV/c protons, 1.45*1013 p/pulse • 60 kJ/spill • 4 bunches separated by 105 ns  1.45*1013 p/spill • Beam size: 0.5(H)x1(V) mm21s

  5. Target design M. Calviani - High-Z target test at HiRadMat - proposal 1409 • Modular and compact device, composed by coaxial elements: • Iridium production material • Inner core is a 5.5 cm Ir, 3 mm Øcylinder embedded into a graphite matrix • Graphite cladding • Water-cooled Ti alloy body

  6. Energy density Max energy density due to beam in the target ~7.5 kJ/cm3/pulse M. Calviani - High-Z target test at HiRadMat - proposal 1409

  7. Temperature transient in Ir rod (AD) • 2200 C° peak temperature single pulse • Temperature gradients of 2000 C° in <1.5 mm • Ir parameters at very high temperature not know in literature M. Calviani - High-Z target test at HiRadMat - proposal 1409

  8. Strain rates M. Calviani - High-Z target test at HiRadMat - proposal 1409 • Strain rates up to 4*104 s-1 • Radial oscillation ~5-25 mm, max radial velocity 65 m/s • Frequency ~1 MHz

  9. Radial stresses M. Calviani - High-Z target test at HiRadMat - proposal 1409 • Rod centre: • Compressive ~10 GPa • Tensile ~6.5 GPa • External surface: • Compressive ~450 MPa • Tensile ~300 MPa

  10. M. Calviani - High-Z target test at HiRadMat - proposal 1409 • No real experience of material behaviour under these extreme conditions exists • Implicit FEM results are a coarse approximation of reality due to high dynamic stresses, high strain rates and high temperatures • Hydro-codes (collaboration with EN/MME): • hydro-dynamic response of material at high pressure and temperature • HiRadMat tests with the objective to: • Cross-check with numerical results (EOS models, strength material models, etc.) • Experimental insights of material behaviour at such conditions

  11. HiRadMat setup M. Calviani - High-Z target test at HiRadMat - proposal 1409 • Material to be tested: • 6 mm Ø rods, ~100 mm long • Iridium, W, WL, WRe (2 for each) + 2 nickel coated + CuCrZr/Ni (~10 total) • Installed on rotated wheel, allowing an alignment accuracy of ≤100 mm • Upstream hBN jaws (~400 mm long, 1l) for beam alignment, 4 planes with 2 axis • Tank in inert atmosphere (He), to avoid oxidation (either leak tight or in slight under pressure with HEPA filters)

  12. Preliminary tank ideas M. Calviani - High-Z target test at HiRadMat - proposal 1409

  13. M. Calviani - High-Z target test at HiRadMat - proposal 1409 • Tank design of proposal 1409 (this) and 1410 could be very similar, with similar alignment requirements and instrumentation

  14. Beam requirements M. Calviani - High-Z target test at HiRadMat - proposal 1409 • Pulse intensity ~1-5*1012 p/pulse • Spot size: 1x1 mm2 1.5x1.5 mm2 • Total number of medium-high intensity pulses: ~300-400 • Ramp-up approach • Other ~200 low intensity pulses could be anticipated • Integral intensity ~2*1015 POT • Beam alignment/stability: • Maximum shift pulse-by-pulse ~100/200 mm • Important to have it guaranteed, not only monitor • Monitor beam asymmetry ~100 mm

  15. Observables and instrumentation M. Calviani - High-Z target test at HiRadMat - proposal 1409 • Radial displacement of the rods, for different longitudinal positions • Attocube FPS3010 interferometer • Temperature increase on the target rod • Fiber-optic based pyrometers • Images of crack propagation and possible particle projections • Fast camera (flash need to be procured) • Strains gaugesat various longitudinal positions • Internal cracks • Ultrasonic sensors (EMAT)

  16. Additional tools M. Calviani - High-Z target test at HiRadMat - proposal 1409 • BLMs • Potentially standard ones installed close to the tank, hBN scan • Beam losses during alignment • “button” BPMs • To be installed on the target seeing the beam to have real-time beam position on target • Resolution ~50-100 mm

  17. Radiation levels (TID, HEH) O(~1013) HEH/cm2/experiment @20 cm O(~50) kGy/experiment @20 cm M. Calviani - High-Z target test at HiRadMat - proposal 1409 • Rad-hard electronics close to the experimental setup • Non rad-hard in the bunker upstream the tables

  18. Effect of a 7.2 us pulse • Long pulse reduces the radial stresses, staying in compressive state rather than oscillating between compressive to tensile • Beam parameters to be adapted M. Calviani - High-Z target test at HiRadMat - proposal 1409 • HiRadMat pulse is ~15x longer than the AD-target one  dynamic response is different

  19. Radioprotection aspects PRELIMINARY M. Calviani - High-Z target test at HiRadMat - proposal 1409 • Pessimistic evaluation based on all protons reaching a single target • ~100 mSv/h at 10 cm after 6 months

  20. Conclusions M. Calviani - High-Z target test at HiRadMat - proposal 1409 • We propose the realization of a HiRadMat test of high-Z target materials • Measurement of radial displacement and cross-check of numerical simulations • Important to assess which beam parameters can be “guaranteed” • Experiment could be foreseen for spring 2015

  21. BACKUP M. Calviani - High-Z target test at HiRadMat - proposal 1409

  22. W rod M. Calviani - High-Z target test at HiRadMat - proposal 1409 • HiRadMat conditions – intensity required to reach 2050 °C ~1.4*1012 p/pulse

  23. Energy density variation M. Calviani - High-Z target test at HiRadMat - proposal 1409