1 / 19

Verification of level 2 is performed by many groups in good co-operation within the SCCVT

Overview of first level 2 verification results presented by Ankie Piters, KNMI, and Vincent Soebijanta, BIRA-IASB. Verification of level 2 is performed by many groups in good co-operation within the SCCVT Special thanks to:

kaoru
Download Presentation

Verification of level 2 is performed by many groups in good co-operation within the SCCVT

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Overview of first level 2 verification resultspresented by Ankie Piters, KNMI, and Vincent Soebijanta, BIRA-IASB • Verification of level 2 is performed by many groups in good co-operation within the SCCVT • Special thanks to: • Jan Fokke Meirink, Marc Allaart, Renske Timmermans, Ronald van der A, Henk Eskes, Michiel van Weele, Jeroen van Gent, Pieter Valks, Jos van Geffen, KNMI • Jose Granville, Pierre Gerard, Jean-Christopher Lambert, BIRA-IASB • Anne Grete Straume, Richard van Hees, SRON • Albrecht von Bargen, DLR/IMF • Johannes Frerick, ESA For providing tools, pictures, and data for this presentation

  2. Outline • Level 2 products • Verification Plans • First results

  3. Verification plans • Objectives of level 2 verification: • Detect errors in the level 1-2 software; • Study the correctness/applicability of the algorithms; • Report on software and algorithm errors and propose changes. • Verification Tasks: • Detect non-physical values • Check for internal consistency • Compare with independent level 2 retrievals • Verification data: • Four orbits between 3 and 11 August have been selected for verification

  4. Verification team • The level 2 verification team, chaired by ESA, consists of algorithm experts from: • DLR • IFE Bremen • KNMI • IUP Heidelberg • BIRA-IASB • SRON • NASA/GSFC • SAO

  5. First results • First Near-Real Time level 2 products are available to the verification team since 2 weeks. They contain: • O3 from UV, O3 and NO2 from visible • H2O, N2O, CO, CO2, CH4 from NIR • Cloud and aerosol products • We still miss slant columns of BrO, SO2, OClO, and H2CO (wrong number of fitting windows)

  6. Ozone column from UV

  7. Solar zenith angle < 88 degrees

  8. O3 Vertical Column Density

  9. O3 Slant Column Density

  10. O3 Air Mass Factor

  11. O3 and NO2 VCD and AMF

  12. Ozone column summary • two orbits of 11 august versus GOME: • We see the same large-scale patterns, no strange values for sza < 88 degrees • histogram of ozone values versus GOME (sza < 88 degrees): • Looks OK for ozone from UV • Ozone from visible much too high (level 1 calibration problem) • Backscan pixels comparable with Forward • Slant Column Density are consistent with DOAS algorithm • Quick-and-dirty comparison with four ground based stations, and with GOME co-locations: • SCIAMACHY ozone roughly 5-10% smaller than ground based stations (wrong cross sections used) • SZA > ~90 degrees: AMFs become negative and 0 (implementation bug) • Errors of less than 5% expected from wrong cloud cover fraction

  13. NO2 columns

  14. Blue: NO2 column < 0 Red: NO2 column > 1016 cm-2

  15. NO2 column summary • NO2 values are realistic for sza < 88 degrees • Slant Column Density are consistent with DOAS algorithm • AMFs for larger solar zenith angles are negative and zero • Backscan pixels comparable with Forward • negative values in the tropics: was the same for GDP 2.4, on which this processor is based. Probable solution: fit H2O and O4 in the same fitting window (it worked for GOME)

  16. Near InfraRed columns • Near InfraRed columns all have unrealistic values, probably due to problems with the level 1 calibration

  17. Conclusions • The level 1-2 Near-Real Time processor is working and ozone and NO2 look as expected for sza < 88 degrees. • Some implementation bugs have been identified and can easily be fixed • Level 1 calibration issues cause problems for a proper level 2 retrieval, especially in the Near InfraRed