3D micro-structuring of diamond for radiation detector applications

3D micro-structuring of diamond for radiation detector applications. B.Caylar , M.Pomorski , P.Bergonzo Diamond Sensors Laboratory CEA-LIST, Gif-Sur-Yvette, France José Alvarez Laboratoire de génie électrique de Paris (LGEP), Gif-sur-Yvette, France Alexander Oh

karif
Download Presentation

3D micro-structuring of diamond for radiation detector applications

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. 3D micro-structuring of diamond for radiation detector applications • B.Caylar, M.Pomorski, P.Bergonzo • Diamond Sensors Laboratory CEA-LIST, Gif-Sur-Yvette, France • José Alvarez • Laboratoire de génie électrique de Paris (LGEP), Gif-sur-Yvette, France • Alexander Oh • University of Manchester, School of Physics and Astronomy, Manchester, United Kingdom • Thorsten Wengler • CERN, Geneva, Switzerland

  2. Context – Whyusing 3D electrodes? Ionizingparticle Electrodes « Sandwich » 3D Electrodes [1] J.Morse, C.J. Kenney, E.M. Westbrook et al. / Nuclear Instruments and Methods in Physics Research Section A, 524 (2004) 236. • Advantages1: • Higher electric field for a given applied bias voltage • Shorter drift path thus drift time • Lower probability of trapping

  3. Context – Whyusing 3D electrodes? • Planar • 3D • Analyticallycalculatedcurrentsgenerated by a MIP

  4. Context – Whyusing 3D electrodes? • NIEL inducesbulkdefects [2] Michal Pomorski – PhD debate, Frankfurt University 07/08/2008 before irradiation after 1.2 x 1014 20MeV n.cm-2 after 1.97 x 1014 20MeV n.cm-2 Signal decrease • When flux increases : • Defectsnumberincreases • Carrier lifetime reduction • CCE decreases

  5. Context – Whyusing 3D electrodes? • Planar • 3D • 3D geometry is faster : 8ns vs 208ps. • 3D geometry makes the detector more radiation hard

  6. Outline • Burriedelectrodes • Laser setup & Fabrication • Structural characterization • Electrical characterization • pc-CVD Detector (e6 detector grade) • Electrical characterization • Characterization under alpha particles • sc-CVD Detector (e6 electronic grade) • Optical characterization • Electrical characterization • Transientcurrentmeasurements • Conclusion

  7. BurriedelectrodesLaser setup & frabrication

  8. Burriedelectrodes – Laser setup 20x Lens Sample holder Nitrogen laser λ = 337nm • τ = 3ns Webcam XYZ Motorized stage • Tunableparameters • Scan velocity 1-1000 µm/s • Laser power 0-160µJ/pulse • Repetition rate 1-30 Hz

  9. Burriedelectrodes – Fabrication Translation Graphitization XYZ Motorized stage • Photoluminescence during • laser processing

  10. BurriedelectrodesStructural characterization

  11. Structural characterization – Optical microscopy • Optical grade sc-CVD sample 10µm diameter 20-100 µm diameter 700µm depth 150 µm • Clean surface (Where graphitization starts) • Cracked Surface (Where graphitization ends) • Tilted sample

  12. Structural characterization – 2D Raman mapping • 2D Raman depth mapping obtained by integrating diamond peak 1000 CCD cts 1000 CCD cts Depth 0 CCD cts 0 CCD cts 10µm 10µm • No micro-channel • Micro-channelwith cracks

  13. Structural characterization – SEM imaging H2Plasma • Channel’s clean side after H2 plasma • Channel’s clean side after laser processing

  14. BurriedelectrodesElectrical characterization

  15. Electrical characterization – I(V) measurements A • ρ(average) = 5.7x10-1 Ω.cm • R(500µm) ~ 2kΩ • Match with nanocrystalline graphite given in literature3 [3] T.Ohana, T.Nakamura, A.Goto et al. / Diamond and Related Materials, 12 (2003) 2011 • Graphite’s channel resitivity

  16. pc-CVD detectorElectrical characterization E6 detector grade 10 x 10 x 0.7 mm3 Sample courtesy Alexander Oh

  17. Electrical characterization – Deviceleakagecurrent A • 3D • Planar • Comparisonbetweenplanar and 3D geometry

  18. pc-CVD detectorcharacterization under alpha particles

  19. Characterization under alpha particles – Experimental setup Fast Charge Sensitive Amplifier M.Ciobanu, GSI, Germany Signal Al back contact FCSA Scope Al front contact Collimator R α Vbias = ±500V Am-241 Source 5.486MeV

  20. Characterization under alpha particles - Results • Planar • 3D • Polarization study – Holes drift (pc-CVD sample)

  21. Characterization under alpha particles - Results • Planar • 3D • Polarization study – Electrons drift (pc-CVD sample)

  22. Characterization under alpha particles - Results α α Amplitude has been normalizedwith the signal of a sc-CVD« e6 electronic grade » diamond • Holes drift (pc-CVD sample)

  23. Characterization under alpha particles - Results α α Amplitude has been normalizedwith the signal of a sc-CVD« e6 electronic grade » diamond • Electrons drift (pc-CVD sample)

  24. Characterization under alpha particles - Analysis α HV +500V V/µm 5 4.5 4 3.5 3 High CCE LowCCE 2.5 700µm 2 1.5 1 200µm 0.5 0 α • Electric field simulation  3D Geometry but pseudo–3D detector

  25. sc-CVD detector E6 electronic grade - <100> oriented 3 x 3 x 0.3 mm3 Sample courtesy Eleni Berdermann

  26. sc-CVD detectoroptical characterization

  27. Detector’soptical characterization – Optical microscopy Detector area Test areas • Micro structuredsc-CVDdiamondobservedwithcrossedpolarizers • Bulkstrainmappingafter graphitization

  28. Detector’soptical characterization – Optical microscopy • Detector aftermetallization

  29. sc-CVD DetectorElectrical characterization

  30. Electrical characterization – Deviceleakagecurrent • HV on cracked surface • HV on clean surface • sc-CVD sample after plasma O2 etching

  31. sc-CVD detectorTransientcurrentmeasurements

  32. Electrical characterization – Setup and methods • Transientcurrentmeasurements HV +100V 2D Zone 2D Zone 300µm Signal Scope Ultra-Fast 40 dB, 2 GHz Broadband Amplifier Ampli

  33. Transientcurrentmeasurements - Results • Withoutcollimator Mixed e/h drift 1 ns Signal 3D~500mV Electrons drift Signal 2D~80mV Holes drift Signal 2D~100mV • Alphas’ injection on cracked side • Alphas’ injection on clean side

  34. Transientcurrentmeasurements - Results • Withcollimator Mixed e/h drift 1 ns • Alphas’ injection on cracked side

  35. Transientcurrentmeasurements - Analysis • Electric field simulation Planar+3D signal +100 V α V/µm 3 2.5 2 1.5 300µm 1 0.5 0 α Planar signal only

  36. Transientcurrentmeasurements - Results • Experimental results Amplitude ratio = 6 • Selection of relevant events

  37. Transientcurrentmeasurements - Results • Analytically calculated signals Amplitude ratio = 23.8 Amplitude ratio = 22 • Theoriticalresponse • 2GHz lowpassfilter

  38. Transientcurrentmeasurements - Results • Analytically calculated signals • Ampli + devicebandwith~350MHz • Rdevice~ 520Ω • 12channelsconnected • Rchannel ~ 6 kΩ Amplitude’s ratio = 6.2 • 350 MHz lowpassfilter

  39. Conclusion • Conductivegraphitic structures has been achieved on both pc- and sc-CVD sample • These structures are suitable for detectors applications • Twodectetorsusing 3D-geometryelectrodes has been produced • A real improvementbetweenplanar and 3D geometry has ben observed • Higher signal • Fasterresponse • « Polarization effect » decrease on pc-CVD detector • But real 3D detector hasn’t been achievedyet…

  40. Thanks for your attention !