1 / 4

Minimal Basic Field Checks for Laser Tracker Systems Decision Matrix

Minimal Basic Field Checks for Laser Tracker Systems Decision Matrix. Common Recommended Practices Minimal Basic Laser Tracker Field Checks. Assumption System has been shipped overseas (airplane) System has been shipped within a country (truck, airplane, car,…)

kassia
Download Presentation

Minimal Basic Field Checks for Laser Tracker Systems Decision Matrix

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Minimal Basic Field Checks for Laser Tracker SystemsDecision Matrix

  2. Common Recommended PracticesMinimal Basic Laser Tracker Field Checks • Assumption • System has been shipped overseas (airplane) • System has been shipped within a country (truck, airplane, car,…) • System has been moved from one to the other plant (truck, car, …) • System has been moved from one to the other working area (put on measurement cart or transportation in white shipping containers “disassembled”, …) Independent of the transportation way, we recommend a basic minimal test procedure. This recommendation is also applicable for daily work. Unterentfelden 2007-07-18, D.Moser -785

  3. Common Recommended PracticesMinimal Basic Laser Tracker Field Checks Basic System Check 2F-Measurement Setup:2 @ -40°, separated horizontally by 90°(measurements on the floor) Two Face Field Check No Check OK ? Yes IFM-Measurement Setup:use of IFM Distance Tool or2 reflector positions at 3m (10ft) in horizonof tracker head BB-Measurement Setup:1 @ 1m (3ft) Ball Bar Field Check IFM Field Check No Check OK ? Yes No Check OK ? Yes ADM-Measurement Setup:1 @ 3.5m (11ft)1 @ largest working range ADM Instrument Field Check Full Compensation Intermediate Compensation IFM Compensation No Yes Check OK ? ADM Instrument Compensation System in specification Unterentfelden 2007-07-18, D.Moser -785

  4. Common Recommended PracticesTolerances for Laser Tracker Field Checks • MetricBall Bar at < 1m, bandwidth  20 mBall Bar at < 3m, bandwidth  60 mTwo Face, bandwidth  0.0012 deg  0.0013 gonBird Bath Distance (IFM)  10 m *ADM Offset Instrument, residuals  25 m • InchesBall Bar at < 3ft, bandwidth  0.0008 inBall Bar at < 10ft, bandwidth  0.0024 inTwo Face, bandwidth  0.0012 deg  0.0013 gonBird Bath Distance (IFM)  0.0004 in *ADM Offset Instrument, residuals  0.0010 in * Repeatability of two determinations Unterentfelden 2007-07-18, D.Moser -785