High Pressure Diffraction and Spectroscopy at Bending Magnet Beamline

High Pressure Diffraction and Spectroscopy at Bending Magnet Beamline. Changyong Park. Beamline Staffs. Beamline operation and user support: Changyong Park: beamline scientist Dmitry Popov: beamline scientist Daijo Ikuta: beamline associate Hongping Yan: post-doc associate

kedma
Download Presentation

High Pressure Diffraction and Spectroscopy at Bending Magnet Beamline

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. High Pressure Diffraction and Spectroscopy at Bending Magnet Beamline Changyong Park

  2. Beamline Staffs • Beamline operation and user support: • Changyong Park: beamline scientist • Dmitry Popov: beamline scientist • Daijo Ikuta: beamline associate • Hongping Yan: post-doc associate • Equipment support: • Curtis Kenney-Benson: beamline associate • Beamline maintenance: • Eric Rod: beamline technician • Arun Bommannavar: beamline control scientist • User administration: • Freda Humble

  3. 16BM-D • General micro-X-ray diffraction and x-ray absorption spectroscopy dedicated to high-pressure physics, chemistry, materials science, and earth and planetary sciences • Optimized for DAC, typically with ϕ ≥ 50 μm gasket (≤ 100 GPa) • 12 μm (v) x 5 μm (h) in FWHM • ~5 x 108 photons/sec at sample (at E = 30 keV) • 6-40 keV normal operation • Up to 60 keV with special request • Powder and single crystal • Sample temperature ranges from 4K to ~1,000K

  4. Beamline Schematic 4 m 40 m from the source 0.6 m Post-mono slits Guard slits Pre-mono slits Vertical KB mirror Clean-up pinhole Si 111 Monochromator Horizontal KB mirror Beamstop E = 6-60 KeV Δ= ~100 μm fixed exit Area Detector 1 m long Cr+Pd mirror 1.5 mrad (45 keV) 200 mmm long Cr+Rh mirror 16BM-D 16BM-C

  5. Equipment • MAR345 Image Plate, MAR165 CCD (APS Detector Pool), Pilatus 1M, and Pilatus 100K • Gearbox or Membrane Diaphragm • On-line Ruby Spectroscopy • Cryostat (4 K He, 10 K LN2) • Resistive heating with PID control • Pneumatic Ion-Chamber Mount • All equipment supports are dedicated to remote controls of the sample pressure and temperature.

  6. Types of experiments suitable at BM-D • Powder diffraction of high scattering (high-Z) materials • Experiments that require various energies • anomalous scattering • low energy for higher resolution in d-spacing • high energy for larger Q coverage • Single crystal x-ray diffraction • Transmission mode XANES (>6 keV) • High-resolution powder x-ray diffraction (with rotating 2θ arm setup, ΔQ/Q = 10-3) • Cryostat (down to 4 K with He flow) • Resistive heating (typically up to 1,000 K) • Static compressional studies at wide range of sample temperature

  7. Micro-XRD and XANES • Simultaneous probe of atomic and electronic structure changes at the same sample condition • Highly reproducible and easily accessible monochromator makes this possible

  8. Improvement Plan • The low incident flux (~5 x 108 photons/sec at 30 keV) is currently the limiting factor to the efficiency. • The distance from the source and the small horizontal mirror acceptance only taking 0.3 mm is the main reason. • Possible improvement of beam flux by :

  9. Concluding Remarks • The recent publication record of 16BM-D (2011: 19, 2012: 28 peer-reviewed publications, ~15-20% high profile journals) outperforms the average BM beamline at the APS. • 16BM-D not only off-loads the oversubscription of the ID beamline, but adds new capabilities in anomalous scattering, x-ray absorption, large Q single crystal diffraction, and high Q-resolution. • Stability of optics and integrity of support equipmentarethe key factors of the high level performance. • The upgrade of optics will promote the more effective use of APS beamtime.