HighPROTEC-2 MCA4-2 Directional Feeder Relay Sales presentation

HighPROTEC-2 MCA4-2 Directional Feeder Relay Sales presentation. 2015/08/10. MCA4 - Key Benefits. Cost savings for field service equipment and commissioning effort Integrated Fault simulation - Faults can be simulated in the device for “dry testing” without external wiring

kera
Download Presentation

HighPROTEC-2 MCA4-2 Directional Feeder Relay Sales presentation

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. HighPROTEC-2MCA4-2 Directional Feeder RelaySales presentation 2015/08/10

  2. MCA4 - Key Benefits • Cost savings for field service equipment and commissioning effort • Integrated Fault simulation - Faults can be simulated in the device for “dry testing” without external wiring • Easy relay configuration achieves high service staff acceptance and minimizes training expenses • Change tracking and plausibility check avoids parameter errors • Optimized overview by hidden protection modules in planning module • Text explanation for all parameter avoids misunderstanding • All in one protection functions by an optimized overview reduced risk of changed customer requirements and to order a wrong devices type • Full Protection package for dir. OC, EC, Recloser, Power supervision, voltage, frequency… • Grid coupling and stabilization functions – Intelligent frequency load shedding for GRID stabilization, Q->U protection, LVRT • With logic, up to 80 equations

  3. MCA4 - Key Benefits • Production and maintenance flexibility • Flexible hardware covers a wide range of nominal values (Vn setting for DI, wide range power supply, wide range voltage measuring, 1A/5A in one version) • Easy wiring at the rear side, pre wiring possible via terminal kit • All terminals are removable, including current measuring terminals • PC Tool Smart View for free • Page editor to create own pages and single lines • Easy connection between PC and Protection device via USB interface • Visualization of tripping curves graphically to get visual feedback of settings and protection concept • Look and feel over the complete HighPROTEC line -reduced training efforts

  4. Product Ordering code - Easy to select • Basic description of Product • Directional feeder protection with logic and control up to 6 switchgears 7 breakers

  5. Meets Global Standards – for the global market Lloyds Register in preparation

  6. Product Features - All in One • Protection functions, one package

  7. Product Features - All in One • Protection functions, Control and Logic - one package

  8. Product Features - All in One • Supervision functions - one package

  9. Product Features - All in One • ANSI functional overview - one package

  10. Product Features – Flexible Hardware • Rear sideX1 Power supply and digital inputsX2 Relay outputsX3 CT measuring boardX4 VT measuring boardX5 / X6 MCA4A = not used MCA4D = add. 6 binary outputs and 8 digital inputs • X100 Ethernet Interface RJ45, (IEC, Modbus, Profibus, DNP3) • X103 Communication Interface (IEC, Modbus, Profibus, DNP3) • X104 IRIG/ Watchdog • Design advantages • Making it easier to apply worldwide • The flexible hardware minimized commissioning, and ordering failures • Wide range power supply 24-270VDC / 48-230VAC • Nominal voltages for the digital inputs are per software settable • VT measurement from 0V up to 800 V AC • CT measurement always with 1A and 5A • All terminal blocks are removable, CT Connector with integrated short circuit device • Housing based on aluminum extrusion parts

  11. Market overview • Protection in medium voltage distribution and generator applications • Applications in different market areas: • Power plants • Infrastructure • Main distribution stations • Commercial buildings • Distribution substations • Industry like Heavy or Process industry • Chemical industry • Power generation – Protection of Generators • Grid Coupling of DER

  12. Application Example MCA4 • Example generation plant with outgoing feeder to different customers and grid coupling to the upper MV distribution network • Usable for incoming, outgoing feeders, bus coupling (synch check), directional feeder applications and at the grid connecting point

  13. Application Control up to 6 Switchgears / breakers, design your own page • Control function up to 6 switchgears • Extended interlocking management • Switchgear timing management • Switchgear status (display Single Line) • PC Tool – Page editor • Page editor, easy to design a single line ormeasuring page

  14. Application Logic – Highest Flexibility • Provides logic editor • Up to 80 equitation's • Select the gate type • Assignment of 4 logic input gates • Output gates with/ without timer • Latched, Set • Reset, Inverter

  15. Commissioning and Maintenance • Fault simulation with the integrated V-I generator without additional wiring • Force and disarm relays, simulate temperatures… • Benefit: Save your Time and Money

  16. Disturbance analyzing • Event recorder • Up to 300 events with ms time stamp • Trend recorder up to 1h • Fault recorder for first analyzing • Disturbance recorder • 32 samples per cycle • Up to 10s per record • Non volatile, 120s memory • Each status event, static or changes, is part of the record • Analyze your faults with low efforts

  17. Product support statement HighPROTEC • Pricing for HighPROTEC-2 Release 3.0 will be unchanged to the actual pricing • Available for sales 01st of October 2015 • Could be ordered now from today • The HighPROTEC devices Release 2.x (with blue front plate) • Will get no functional update • List price increase for Basic Products (not options) +20% • Available for sales next two years • Repair and support time minimum 7 years (1 of Oct.)

  18. Anyquestions, remarks? Thanks for your attention