Fall 2009. Module 8 Inverters. Inverters. Converts the DC power produced by the solar modules into AC power used on the utility grid. History. Inverters have been the weaker link in PV systems Early inverters were unreliable Early inverters were inefficient which penalized an entire system.

kermit-ruiz
Download Presentation

Fall 2009

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Fall 2009 Module 8 Inverters

  2. Inverters • Converts the DC power produced by the solar modules into AC power used on the utility grid

  3. History • Inverters have been the weaker link in PV systems • Early inverters were unreliable • Early inverters were inefficient which penalized an entire system

  4. Inverter Types • Square Wave • Modified square wave • Sine wave

  5. Square wave • Step-function or “square” alternating current output • Considerable harmonic distortion • For small resistive heating loads

  6. Modified Square Wave • Complex circuits used to switch DC into AC. • More appropriate for operating a wide variety of appliances • Still noise will be picked up by sensitive equipment

  7. Sine Wave • High quality wave form • Most common inverters today • Little harmonic distortion

  8. The wave…comparison

  9. Inverter manufacturers • SMA (Sunny Boy) • Fronius • Xantrex • Outback • PV Powered • Kaco • Enphase – Micro Inverters

  10. The Guts

  11. Some examples

  12. Enphase Micro-Inverter

  13. All Installed

  14. Installing SMA

  15. Optional Inverter Features • Remote control operation and data-monitoring • Load transfer switch-allows system to meet critical loads during power failure • Series and Parallel connectivity for multiple inverters • Individual module performance monitoring

  16. Ideal Inverter Features – now standard • Maximum power point tracking (MPPT) • Low harmonic distortion • Near perfect Sine wave shape • Ground Fault Protection • AC/DC disconnects • Weatherproof enclosure

  17. Specifying an inverter • Grid Tied:Watts Output AC-computed STC rated watts of PV panels • Stand-Alone: based on peak load • Input Voltage-usually between 75 and 480 VDC, called the window or range • Insure that the voltage will not drop or exceed this range because of climatic conditions or inverter will not function • Output Voltage:120, 240, 208, 480 • Frequency: U.S. is 60Hz

  18. Specifying an inverter • Grid Tied:Watts Output AC-computed STC rated watts of PV panels • Stand-Alone: based on peak load • Input Voltage-usually between 75 and 480 VDC, called the window or range • Insure that the voltage will not drop or exceed this range because of climatic conditions or inverter will not function • Output Voltage:120, 240, 208, 480 • Frequency: U.S. is 60Hz

  19. Grid Tied Inverter Sizing • Sized based on the amount of watts we pass through the system at any one time • Size of inverter is the labeled watts • an SMA 3000 is a 3000 watt inverter • The most power that will pass through this inverter is 3000 watts • If the output is 240 volts, the current will be 12.5 amps • 3000W ÷ 240v = 12.5 amps

  20. String Sizing Software

  21. And sized by… • PV system component package (grid tied) • The Grid Tied PV system will be based on other factors • Budget • Roof Size • Rebate/Tax incentives