1 / 10

X700 Training Course

X700 Training Course. Power Control. X700 Power Control Section. The X700 Power Control Section consists of the following components:

kerry
Download Presentation

X700 Training Course

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. X700 Training Course Power Control

  2. X700 Power Control Section The X700 Power Control Section consists of the following components: 1.) SM-PWR IC (U304): U304 is a power management ASIC with complete on/off logic and charging control, regulators, LED drivers, 8 ohm speaker & vibrator driver. Controlled by S-GOLD over the I2C interface. 2.) Companion IC (U300): U300 is an ASIC that complements U304 providing additional functionality like back-up battery charging, boost converter, additional regulators and audio switching including stereo/mono headset. Controlled by S-GOLD over the I2C interface. 3.) Battery: A single 780mAH (Li-Ion) cell with a nominal voltage of 3.7V. 4.) Back-Up Battery: 3.0V, 0.5mAH coin cell. 5.) Charger: 5.6V, 700mAH applied at the I/O Connector.

  3. X700 Power Control Section Description of X700 Power Supplies

  4. X700 Power Control Section Layout – X700 Power Control Section

  5. X700 Power Control Section Schematic: Companion IC

  6. X700 Power Control Section Schematic: SM-POWER IC

  7. X700 Power Control Section Power Control Logic The power on sequence can be initiated when a valid battery voltage is applied (VBATT>3.1). One of following conditions start the Power Up sequence. 1.) Power key is pushed for more than (1,000)ms 2.) Application of a charger voltage EXT_PWR>4.0v 3.) Real Time Clock alarm generated by U100(SGOLD) RTCOUT=1 The Power Up sequence is as follows: 1.) U304 band gap reference is activated. 2.) U304 checks VBATT voltage. If VBATT>3.1 then power-up, Else check for VBATT while power-up event is valid. 3.) The following U304 regulators are enabled in sequence: VRF2, SDBB, VLBB2, VLBB1, VINT, VANA, VSIM1, V28, VSD, VUSB. 4.) After U304 VINT is enabled, U300 VLBB3 is also enabled. 5.) After U304 VUSB is enabled, U304-41(INTOUT) will go low followed by U304-48(RESET_N) going high releasing U100 SGOLD from reset. 6.) U100 boot code will determine if the power-up sequence is valid. If valid then provide clock to U200 (13MHz and 32kHz) and release U100 from reset (AP_RST); Else send ALL_OFF command to U304 to power-down the system. 7.) U200 power-up to complete the turn-on sequence.

  8. The power-down sequence of the phone is as follows: Power-down sequence is initiated by the detection of a valid SW428 ON/OFF key press or a low battery voltage condition has been detected. U200 determines that a valid power-down sequence was detected. U200 disables both active hardware and software application. After U200 power-down sequence is completed, a command to U100 is sent to disable U304. U100 initiates its power-down sequence then resets U200 and remove clock. After U100 power-down sequence is completed, an ALL_OFF command to U304 is sent to disable all regulators. X700 Power Control Section

  9. X700 Power Control Section Batter Charging & Monitoring: The estimated battery capacity is displayed as a LCD battery icon. It is derived from battery voltage and current consumption measurements.

  10. Any questions?

More Related