1 / 15

The Automatic Generation of Merged-Mode Design Constraints

The Automatic Generation of Merged-Mode Design Constraints. Subrangshu K. Das, Texas Instruments Ajay J. Daga, FishTail Design Automation Aishwarya Singh, Texas Instruments Vikas Sachdeva, FishTail Design Automation. Constraints Development Challenges.

kevyn-knox
Download Presentation

The Automatic Generation of Merged-Mode Design Constraints

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. The Automatic Generation of Merged-Mode Design Constraints Subrangshu K. Das, Texas Instruments Ajay J. Daga, FishTail Design Automation Aishwarya Singh, Texas Instruments Vikas Sachdeva, FishTail Design Automation

  2. Constraints Development Challenges • Number of operatingmodes supported in a design today has increased tremendously (>20) • Each operating mode could be unique in terms of its timing requirements • Constraints designer needs to understand all these “unique” timing requirements and capture them in the constraints

  3. Prior Solutions • Single-mode implementation flow • Using most timing-critical “operating” mode • E.g., if freq. clkb > freq. clka, • SDC-1: set_case_analysis 1 sel • Single timing-critical mode is extremely rare • Multi-mode implementation flow • Separate constraint files for each “operating” mode • SDC-1: set_case_analysis 0 sel • SDC-2: set_case_analysis 1 sel • Easy to create but tool run-times become prohibitive beyond 2-3 modes (on complex IPs) • Merged-mode implementation flow • Created by collapsing constraints for multiple “operating” modes into one • No case-analysis • SDC-1: set_clock_groups –logically_exclusive –group clka –group clkb • Effort intensive and error-prone • No easy way to review FF2 FF1 clka 0 clkb 1 sel • Ideal Solution: Designer creates individual mode SDC files and a tool automatically collapses them and alsogenerates the clock-exceptions!

  4. Key Components for “automation” • Ability to define boolean condition required to propagate a clock signal from one node to another • Ability to calculate dot-product between two sets of boolean expressions to see if 2 clocks can interact or not • False-path if dot-product == 0 FF2 FF1 clka 0 clkb 1 sel • TI and Fishtail collaborated to enhance Focus (formal tool) to handle above and generate exceptions automatically during merging

  5. Enhancements in Focus • Mode-table • Case-analysis to block clock propagation • Clock-propagation false-path • Logically-exclusive • Partially-exclusive

  6. Automated Constraints Generation Flow

  7. Focus Results • Design Statistics • Complex IP with ~1.6 Million instances • Multiple clocks (~25) with highest clock frequency being 266 MHz • ~30 operational modes including test modes • No missing / erroneous exceptions • Constraints un-touched in the course of the entire P&R and STA flow

  8. Focus helped catch design bugs! • DFT clock implementation is complex and is custom-built for every IP • Verifying DFT clock implementation is difficult using conventional techniques for scenarios like: • Ensure ATPG shift and ATPG capture clocks do not interact in any of the operating modes • No timing paths in the design between 2 ATPG capture clocks (programmed for simultaneous capture) in TFT • However constraint designer assumesabove when writing constraints • Design implementation bug can easily get un-detected till late in the design or worse after Si! • Focus formally proves if 2 clocks are mutually-exclusive and then generates clock-exception in merged SDC • Absence of clock-exceptions (clock-crossing report) with help of clock-propagation/interaction reports helped catch implementation bugs (>5)

  9. Conclusions • Described how Focus was used to • Automatically generate merged-mode constraints from mode-table spreadsheet • Automatically generate clock-exceptions to remove pessimism • Helped reduce constraint development cycle-time by a factor of 2-3X • No last-minute heart-aches due to constraint bugs!!  • Described how Focus helped in catching implementation bugs that could have been missed in conventional verification

  10. Thank You

  11. Mode-table spreadsheet Configuration ports Operating Modes Configuration registers Back

  12. Case-Analysis to Block Clock Propagation FF1 FF2 CLKA 0 CLKB 1 mux1 1 1 0 SEL1 SEL2 1 0 • Modes being Merged • MODE1 • MODE2 • set_case_analysis 1 mux1/s Back

  13. Clock Propagation False-path FF2 FF1 CLKA 0 0 mux1 1 TCLK mux3 1 TESTMODE CLKB 0 mux2 1 SEL • set_clock_sense –stop_propagation –clocks {TCLK} [get_pins mux3/b] Back

  14. Logically-Exclusive Clocks • PICLK0 – functional clock • AUXCLK0 – shift clock • SE – scan enable • set_clock_groups –logically_exclusive –group AUXCLK0 -group PICLK0 FF2 FF1 AUXCLK0 ICG PICLK0 0 AUXCLK0 1 mux1 SE = 0 SE SE = 1 Back

  15. CLKA CLKB Partially-Exclusive Clocks • create_generated_clock mux1/Z –name clka_1 –master_clock CLKA • create_generated_clock mux1/Z –name clkb_1 –master_clock CLKB • set_clock_groups –physically_exclusive –group CLKA –group CLKB FF1 FF2 FF4 FF3 0 1 mux1 Back