540 likes | 736 Views
K Series Packaged Units & Commercial Split Systems- 2011. Overview. Commercial Market Strategy Replacement Market Focus K Series Products KGA, KCA, KHA T Series Large Split Systems (6-20 ton) TSA, TPA, TAA Small Split Systems (3-5 ton) 4SCU13, 4SHP13, ACBX32.
E N D
Overview • Commercial Market Strategy • Replacement Market Focus • K Series Products • KGA, KCA, KHA • T Series Large Split Systems (6-20 ton) • TSA, TPA, TAA • Small Split Systems (3-5 ton) • 4SCU13, 4SHP13, ACBX32
2010 Commercial Regional Distribution Center (CRDC) C200 Calgary CRDC 7 US & 2 Canadian CRDC’s for quick product access Brampton CRDC
2010 Commercial Regional Distribution Center (CRDC) • In stock for quick delivery or pickup • Ship direct to job site • Great for replacement • Wide range of field installed accessories • Available factory options Regional Distribution Centers
2-25 Ton Overview • Tonnages Gas / Electric (KGA) = 2, 2.5, 3, 4, 5, 6, 7.5, 8.5, 10, 12.5, 15, 17.5, 20 & 25 Electric / Electric (KCA) = 2, 2.5, 3, 4, 5, 6, 7.5, 8.5, 10, 12.5, 15, 17.5, 20 & 25 Heat Pumps (KHA) = 2, 2.5, 3, 4, 5, 6, 7.5, 8.5, 10, 12.5, 15, 20
2-25 Ton Overview • K Series replaces T Series Products • K Series backward compatible to T Series • K Series B Box units require a return air adaptor plate • Field & factory installed accessories available • Lead time for some factory installed CTO accessories • Variety of roof curb styles and types available • ASHRAE 90.1 Complaint • Products meet 2010 efficiency requirements
2-25 Ton Overview Large Access Panels • Serviceability Features • Common Parts • Plastic Drain Pans • Color coded & continuously marked wiring • Fork slots on 3 sides with rigging holes at the corners • Large access panels • Thermal expansion valve with removable element Fork Slots Unit Rigging
Box Size Overview • A Box • Gas Electric & Electric Cooling 2-6 ton • Heat Pump 2-5 ton • A+ Box • “Stretched” A Box • 8” taller, 13” longer, same depth • Gas Electric 7.5 ton • Single Circuit- 1 compressor • Heating Capacity up to 150,000 BTUH • Heat Pump 6 ton • Single Circuit- 1 compressor
Box Size Overview B Box (7.5-12.5 ton) C Box (15-25 ton) Multiple circuits 15 ton units- 2 compressors 17.5, 20, 25 ton units- 3 compressors Gas Electric & Electric Cooling (15-25 ton) Heat Pump (15-20 ton) • Dual circuit 7.5 ton capacities • Gas Electric, Electric Cooling & Heat Pump 15 ton unit with 2 compressors
C Box Layout Economizer Dampers (optional) Condenser Fans Gas Heat Section Indoor Coil Compressors Belt Drive Blower Motor
Accessories- Field Installed • Coil Protection • Coil guards • Hail guards • Controls • Smoke detectors • Cooling Accessories • Compressor crankcase heaters • Low ambient kits • Condensate Traps • Copper • PVC
Accessories- Field Installed • Ceiling Diffusers • Step down • Flush • Ceiling diffuser transitions used with roof curb
Accessories- Field Installed • Electrical accessories • Disconnect kits (Factory Also) • GFI service outlet • Horizontal Conversion • Horizontal discharge kit
Accessories- Field Installed • Gas Heating Accessories • Bottom gas piping kit • Combustion air intake & vertical vent extension kits • Low temperature vestibule heater • LP kits
Accessories- Field Installed • Indoor Air Quality • UVC germicidal lamps • High Efficiency MERV 8 & 13 filters on certain models • CO2 Sensors- Wall or plenum mount
Accessories- Field Installed • Outdoor Air Options • Outdoor air dampers- (Factory Also) standard & motorized • Introduce up to 25% outdoor air- required by local codes • Power exhaust fans
Accessories- Factory Installed • Build to Order on some factory installed options • 10-12 week lead time • Corrosion Protection • evaporator coil, condenser coil or both • Hinged Access Panels • economizer, filter, compressor, controls, heating, blower sections
Accessories- Factory Installed • Stainless Steel Heat Exchanger • 15 year warranty • Low & High Static Blower Drives • Low static drives ideal for warehouses • High static ideal for add on cooling applications with existing ductwork • Gas Heat Options • Medium and high heat capability • Voltage Options • 208/230, 3 ph, 460, 3 ph or 575, 3ph
Accessories- Factory & Field Installed • Economizers • Provide outdoor air for cooling instead of mechanical cooling- saves money on electrical consumption- can introduce up to 100% outdoor air • Why use economizers? • Reduce the need for mechanical cooling- save $ on electrical consumption • Some buildings need cooling all year long- people add heat as well as computers & assembly processes • ASHRAE Standards (90.1) • Require economizers and/or a certain percentage of outdoor introduction in commercial buildings in some parts of the country
Accessories- Roof Curbs & Adaptors • Roof curbs • Cliplock (8, 14, 18, 24”) • Hinged (8, 18, 24”) • Standard (14, 24”) • Roof curb adaptors needed for replacement applications • Allied Commercial unit replaces a competitive unit • Existing roof curb remains on the roof • Roof curb manufacturers can provide pricing and lead times • Old unit & replacement unit model numbers needed
Commercial Sales Tools • Product Information & Learning Tools • 1) Website • http://www.allied-commercial.com • 2) Commercial Catalogs • Spec Sheets, Sales Brochure • 3) E-Learning CD • Audio & video tutorial of K Series product line • Links to installation instructions & spec sheets
Commercial Sales Tools www.allied-commercial.com
T Series Split Systems TSA – Condensing Units TPA – Heat Pumps TSA 072- 6 ton TSA090- 7.5 ton TSA180- 15 ton TSA240- 20 ton TSA 120S- 10 ton TSA120D- 10 ton TSA150- 12.5 ton TPA090- 7.5 ton TPA120- 10 ton
T Series Split Systems • Availability • CRDC to stock AC/HP and standard drive coil blower units • Build To Order (BTO) options • (Factory installed but longer lead times) • Low Static Drive (0”-0.8” static) • High Static Drive (0.6”-1.2” static) • Coil Coating (1.0”-1.8” static) • Voltage Options • 208/230, 3 ph, 460, 3 ph or 575, 3ph
Commercial Split Systems • Many field installed options • UVC • High end MERV Filtration • Electric Heat • Hot Water • Economizer • Hail Guards • Coil Guards • Return Air Grilles • Float Switch Kit • Freezestat Kit • Low Ambient Control (0⁰F)
Commercial Split Systems • Check spec sheets for details and ratings: TSA TAA Coil Blowers-Single/Dual (6-20 ton) TPA TAA Coil Blower (7.5, 10, 15 ton)
TAA Air Handlers TAA – Air Handlers Multi-Position (Up / Horizontal TAA 072- 6 ton TAA090- 7.5 ton TAA 120- 10 ton TAA150- 12.5 ton TAA180- 15 ton TAA240- 20 ton
Fully Assembled Units Commercial Split Systems • Factory installed : • Motors • Pulleys • Belts • Controls • Wiring • TXV/s Main
TAA Air Handlers • Multi-Positional Air Handler • Vertical • Horizontal • Right/Left Main
TAA Air Handlers Unit Layout
TAA Air Handlers All Sides Access Blower Access Bearing/Blower Access Full Access Front Back Filter Access
TAA Air Handlers • TAA (7.5-20 Ton) • Independent Circuits • Independent TXV’s • Manifold (field Supplied) for converting to single circuit • Access to refrigerant lines on both sides of cabinet TAA- 50/50 Face Split Coil Main
TAA Air Handlers Factory Static Options High static drive (BTO-extended lead time) ~1.0” – 1.8” @ 400cfm/ton Standard drive (Stocked) ~0.6” – 1.2” @ 400cfm/ton Low static drive (BTO-extended lead time) ~0” – 0.8” @ 400cfm/ton Main
TAA Air Handlers Control Box • Fully assembled • Simple electro-mechanical controls • Field re-locatable Main
TAA Air Handlers Plastic Drain Pan • Corrosion resistant • Removable • Relocatable • Reversible • Deep • Sloped for no standing water • Float switch option Main
TAA Air Handlers MERV 10 or 16 Options • 16” x 25” filter size in all large split air handlers 6-20 ton • 5” Filter provides longer life • Installs easily with 2 replacement rails • MERV 16 can help qualify for LEED credits • Same size filters as residential units therefore readily available Main
TAA Air Handlers Blower Motor Can be removed/installed by one person Removal with 2 bolts
TAA Air Handlers • Install within minutes/not hours (Requires 1 person to install) • No safety interlock switches to wire or install • Lamp assemblies snap in place (No screws necessary) • Ballast mount on outside of air handler for operation visibility • LED for power - standard • LED for light(s) - standard UVC Light Kits
TSA/TPA Outdoor Units Compressor Accessibility • Compressors designed at front of unit for access • Also standard: • Loss of charge switches • High pressure switches • Filter driers Main