0 likes | 16 Views
Atomic absorption spectrophotometer comes with Deuterium lamp for background correction, RS232 interface, Multi-linear and nonlinear curve fitting. <br>Its double beam system automatically compensates the light source drift and wavelength drift caused by the variation of temperature and electronic <br>circuit drift so as to reach a good basic line stability. The specially designed fine light beam passes through the flame to ensure a high precision <br>analytical test and low characteristic concentration in this atomic absorption spectrophotometer. It has multiple applications in research
E N D
Personalized PDF Catalog Catalog Generated On : 29/11/2023 Atomic Absorption Spectrophotometer
https://www.labtron.info/ info@labtron.info | Description : Atomic absorption spectrophotometer comes with Deuterium lamp for background correction, RS232 interface, Multi-linear and nonlinear curve fitting. Its double beam system automatically compensates the light source dri? and wavelength dri? caused by the variation of temperature and electronic circuit dri? so as to reach a good basic line stability. The specially designed fine light beam passes through the flame to ensure a high precision analytical test and low characteristic concentration in this atomic absorption spectrophotometer. It has
multiple applications in research and development and industrial analysis. Specifications : Wavelength range 190 - 900 nm Spectral 0.2 nm, 0.4 nm, 0.7 nm, Bandwidth 1.4 nm, 2.4 nm, 5.0 nm Wavelength ≤ ± 0.5 nm accuracy Wavelength ≤ 0.3 nm(single direction) repeatability Baseline dri? ± 0.004 Abs / 30 min Resolution < 40 %
Characteristic concentration ≤ 0.04 mg / ml / 1 % (Cu) Detection Limit 0.008 mg/ml (Cu) Background Greater than 30 times calibration ability Power supply 220 V / 3 A, 50 Hz Gross Weight 160 kg Dimension (L × W 1220 x 770 x 730 mm × H)
Features : Double Beam system to compensate the light source dri? and wavelength dri? Build-in computer data processing and LCD display No pre-heating of Cathode lamp for a long time to analyze the sample High precision of measurement
Multi-functional analysis mode Fast analysis of sample High energy optical path Safe and reliable gas path system Electronic circuit dri? to reach a good basic line stability Applications :
Atomic absorption spectrophotometer is used to analyze elements in agriculture, chemical, environmental study, food, mining, and petrochemical, pharmaceutical industries.
www.labtron.info Labtron Equipment Ltd. Quatro House, Lyon Way, Camberley, Surrey GU16 7ER United Kingdom
Email: info@labtron.info | Website: https://www.labtron.info/ | Phone: +44 2080 043 608