An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. HE DOE-Optimization Design of Heat Exchanger Justin Hollman Steve Williams Anthony Joseph Michael Dunkin Michael Gill

  2. Process of Design and Optimization • Adjust settings of input to achieve R=1 design. • Analyze each factor of design to find factors that will affect output. • Selected mass flow rate through the shell, baffle spacing, tube outer diameter, tube length, and shell inner diameter. • Execute optimization using effects plots, interaction plots, pareto charts, and other statistical optimization tools. • Input optimized results into program to observe results. • Repeat for 2nd run.

  3. Heat Exchanger Pareto Charts • 2nd level correlations were chosen after correlation comparison showed that they had better composite desirability. • All chosen factors are of considerable importance to some response.

  4. Effects Plots for Chosen Factors • Chosen factors not removable due to considerable affect on system outputs. • Factors chosen based on analysis of each individual factor.

  5. Optimization with Output. Heat Transfer Rate ====================================== Desired Heat Transfer Rate = 77153.12 W Calculated Heat Transfer Rate = 55097.29 W Difference = 22055.83 W Desired-to-Calculated Ratio = 1.40 Heat Exchanger Geometry Considerably Under Sized Increase Heat Transfer Coefficient or Surface Area Shell Reynolds Number Outside the range for Friction Factor Equation Shell Side Pressure Drop May Have A Higher Error HE Pressure Drop ===================== Shell Side Delta-P = 445382.84 Pa Tube Side Delta-P = 523.22 Pa Heat Exchanger Weight ===================== Shell Weight = 0.85 kg Tube Weight = 8.33 kg Shell Fluid Weight = 8.04 kg Tube Fluid Weight = 5.45 kg ----------- Total HE Weight = 22.66 kg ************************************** Successfull Termination **************************************

  6. Heat Exchanger Pareto Charts for 2nd run. • 2nd level correlations were chosen after correlation comparison showed that they had better composite desirability. • All chosen factors are of considerable importance to some response.

  7. Heat Transfer Rate ====================================== Desired Heat Transfer Rate = 77613.91 W Calculated Heat Transfer Rate = 55295.87 W Difference = 22318.04 W Desired-to-Calculated Ratio = 1.40 Heat Exchanger Geometry Considerably Under Sized Increase Heat Transfer Coefficient or Surface Area Shell Reynolds Number Outside the range for Friction Factor Equation Shell Side Pressure Drop May Have A Higher Error HE Pressure Drop ===================== Shell Side Delta-P = 450201.60 Pa Tube Side Delta-P = 523.21 Pa Heat Exchanger Weight ===================== Shell Weight = 0.85 kg Tube Weight = 8.33 kg Shell Fluid Weight = 8.04 kg Tube Fluid Weight = 5.45 kg ----------- Total HE Weight = 22.66 kg ************************************** Successfull Termination ************************************** Optimization with Output. Results are similar to 1st run.