200 likes | 426 Views
EPA Phase 1 Program <0.60 lbs/MBTU InEPA Phase 2 Program Effective in 2010<0.32 lbs/MBTU Out and <18g/hrIRS 30% (up to $1500) Tax Credit Program> 75% Lower Heating Value Efficiency. Regulations Overview. . 4 Heat load Tests using 4"X4" Oak 100%, <50%, <25%, <15% lbs/Million BTU Output
E N D
1. Model 200SSRII
2.
EPA Phase 1 Program
<0.60 lbs/MBTU In
EPA Phase 2 Program Effective in 2010
<0.32 lbs/MBTU Out and <18g/hr
IRS 30% (up to $1500) Tax Credit Program
> 75% Lower Heating Value Efficiency
3.
4 Heat load Tests using 4”X4” Oak
100%, <50%, <25%, <15%
lbs/Million BTU Output is a weighted average of all 4 tests
<15% heatload is the highest weighted test
4.
Stove cycles on and off during test due to low heatload
Minimizing the # of cycles will produce less emissions
Add heat storage, i.e. water, to minimize # of cycles (Model 200SSRII has 377 gallons of water, Model 200SSR has 205 gallons of water, Model 200CSS has 114 gallons of water)
Increase water temperature span to minimize # of cycles (Model 200SSRII and 400SSR run from 145oF to 185oF)
Increase efficiency with new flue
Stove still must be clean enough to pass