Status of Tev IPMs April 1, 2009. Andreas Jansson. Recent work. After the power outage on February 11, IPMs stopped reporting data to ACNET Software detected persistent buffer errors bits, marking data as bad VIPM: Buffer 1/2 mismatch HIPM: Pbar marker error Swapped cables, to locate error
E N D
Status of Tev IPMsApril 1, 2009 Andreas Jansson
Recent work • After the power outage on February 11, IPMs stopped reporting data to ACNET • Software detected persistent buffer errors bits, marking data as bad • VIPM: Buffer 1/2 mismatch • HIPM: Pbar marker error • Swapped cables, to locate error • Buffer mismatch followed upstairs PC • Pbar error followed downstairs crate. • Pulled buffer boards from vertical system for bench test. • Left horizontal PC monitoring vertical signals • Bench tested boards, finding nothing out of the ordinary • Upgraded test stand labview code and re-tested, saw nothing • Reinstalled, buffer mismatch problem gone • Had to distable signals from horizontal front end board 1, which was causing the pbar marker error. • Mechanics now seems to be working properly IPM status
Current store January 2009. IPM status
Good data IPM status
Marginal data IPM status
Bad data IPM status
Conclusions • The IPM DAQ system is working properly again, reporting to ACNET • Signals are smaller than they used to be, fluctuating a lot and occasionally disappear altogether • Not due to stochastics of gas interaction • HV ruled out as a culprit(?) • Gas pressure fluctuating? • Not currently understood IPM status