320 likes | 613 Views
Multi-Channel Fabry-Perot Etalon. E. Dagher , R. Liu, J. Vaillancourt. Outline. Objectives Division of Work Background Mirror Fabrication Cavity Fabrication Biomaterials. Sample Preparation Test Procedure Results Timeline Future Work Conclusion. Objective.
E N D
Multi-Channel Fabry-Perot Etalon E. Dagher, R. Liu, J. Vaillancourt
Outline • Objectives • Division of Work • Background • Mirror Fabrication • Cavity Fabrication • Biomaterials • Sample Preparation • Test Procedure • Results • Timeline • Future Work • Conclusion
Objective To design and build a proof of concept experiment for a novel high sensitivity biosensor based on a Fabry-Perot cavity
Division of Work • Initial Design Simulations and Evaluation • Sims Approach Research and Evaluation • MS Excel • Biomaterial Sample Prep Rui: Jarrod: • Fabricate device for testing • Obtain materials • Assemble the prototypes • Build test setup Emile: • Write test programs to acquire data • Control instruments • Demodulate the signal • Graph results • Automate the testing/graphing procedure
R=.3 R=.9 R=.5 λm+1 λm-1 λm • Important Properties of a F-P Cavity: • Free Spectral Range: • Finesse: • Resonant Condition: where m=1,2,3 … Background
Glass Glass Glass Glass Glass Glass Glass Glass Glass Glass Air Air Mirrors Glass Glass Glass Glass Glass Glass BIO Material
Mirror Mirror Mirror Mirror Glass Glass Glass Glass Glass Glass Glass Glass Glass Glass Air Air Air Air Glass Glass Glass Glass BIO Material
Mirror Fabrication • Mirrors will be formed using AJA 7000 Sputtering System • Many metal coatings available • Au, Ag, Al, Ti, Ni, Cr • Low pressure for high quality films • Precise control of the thickness
Mirror Fabrication Glass Titanium Gold
Mirror Testing Transmission @ 1.55µm Glass: 87% 10Å Ti / 40Å Au: 47% 10Å Ti / 70Å Au: 18% 10Å Ti / 40Å Au 10Å Ti / 70Å Au
Cavity Fabrication • Reason for Failure: • Only 150Å of gold • Missing the “sticking layer” • Solution: • Use a sticking layer • Can be Ni, Ti, Cr
Biomaterials • Biomaterials in cavities: • Protein G • IgG • Fab • Same Concentration for all experimental setups
Coating Biomaterials Glass Protein G IgG Protein G IgG Glass Gold
Testing Block Diagram GPIB/IEEE Cable PC/Matlab Single Mode Fiber Micron Optics si720 Optical Sensing Analyzer Detected light Power Input Test Setup
Matlab GUI Interface Start Folder/File location to save data Start/Stop Wavelengths Figure
Test Automation Block Diagram Run Matlab GUI Locate File/Folder Location to save data Start/Stop Wavelengths -Set the Start/Stop Wavelengths on Optical Analyzer -Start Sweeping through wavelengths -Get data results and save them in specified folder Start Show Results
Future Work 1. Multi-channel Fabry-Perot cavity waveguide structure. Mirrored Ends Multiple Channels Silicon Waveguide Silicon Substrate Silicon substrate
Future Work 1. Multi-channel Fabry-Perot cavity waveguide structure 2. Integrated with microfluidics Biomaterials Fluid Cavity Polymer Cap
Waveguide with microfluidics • Benefits: • Reduced device size • Can create more channels for biomaterials • Enables mass production • Uniform device size Biomaterials
Conclusion • Fabrication of Cavities is feasible • Goal has been reached • Introduce mirror reflectivity as a variable when testing