1 / 9

Transients to be Analysed for the LBE–cooled XT-ADS and Lb–cooled EFIT designs

Transients to be Analysed for the LBE–cooled XT-ADS and Lb–cooled EFIT designs M. Schikorr (FzK) EUROTRANS-DM1-Safety Meeting Bruxells, 17 March 2006. Topics of this discussion: Types of Typical Plant Transient Initiators to be analyzed for the LBE / Lb – cooled ADS designs

kyoko
Download Presentation

Transients to be Analysed for the LBE–cooled XT-ADS and Lb–cooled EFIT designs

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Transients to be Analysed for the LBE–cooled XT-ADS and Lb–cooled EFIT designs M. Schikorr (FzK) EUROTRANS-DM1-Safety Meeting Bruxells, 17 March 2006 EUROTRANS DM1 Safety Bruxells, 17 March 2006

  2. Topics of this discussion: • Types of Typical Plant Transient Initiators to be analyzed for the LBE / Lb – cooled ADS designs 2. Summary of Results of the Transient Analyses of the 80 MW LBE – cooled XADS (ANSALDO Design) 3. List of Transients that were analyzed for the PDS-XADS 4. List of Transients to be analysed for XT-ADS and EFIT EUROTRANS DM1 Safety Bruxells, 17 March 2006

  3. 1. Typical Plant Transient Initiators for : - Protected case (with normal shutdown) and - Unprotected case (shutdown failure). 1. Loss of Flow (LOF) : pump failure 2. Loss of Heat Sink (LOH) : heat sink failure 3. Overpower Transient (TOP) : reactivity insertion 4. Loss of Coolant (LOCA) : primary system leak 5. Design specific transients : i.e. HX tube rupture, jet etc. EUROTRANS DM1 Safety Bruxells, 17 March 2006

  4. 2. Summary of XADS Safety Transient Analyses : 1. For the LBE-cooled 80 MWth XADS, as designed by ANSALDO, no transient could be identified that could lead to severe or catastrophic consequences. • For the worst combination of transients (ULOH+ULOF) the „grace“ time until excessive clad temperatures (> 1000 °C) are reached is between 30 and 60 minutes. 3. The dynamic response of the system is in general very benign to all transients considered, mainly due to it‘s : a. large heat sink / heat buffer capacitiy provided by the LBE coolant, and b. excellent natural convection characterisitics of the core/plant design (that is specfic to the Ansaldo XADS design !!!!) EUROTRANS DM1 Safety Bruxells, 17 March 2006

  5. 3a. List of Transients that were analyzed for the LBE-cooled 80 MW PDS-XADS (Ansaldo-Design) EUROTRANS DM1 Safety Bruxells, 17 March 2006

  6. 3b. List of Transients that were analyzed for the LBE-cooled 50 MW Myhrra (SCK-CEN Design) Source : D66 PDS-XADS EUROTRANS DM1 Safety Bruxells, 17 March 2006

  7. 3c. List of Transients that were analyzed for the Lb-cooled BREST Reactor Design Initiating events of ultimate accidents without scram (WS): EUROTRANS DM1 Safety Bruxells, 17 March 2006

  8. 3d. Preliminary List of Transients to be analyzed for the LBE- cooled XT-ADS Design. Preliminary List is currently defined as : EUROTRANS DM1 Safety Bruxells, 17 March 2006

  9. 3e. Preliminary List of Transients to be analyzed for the Lb-cooled EFIT Design. Preliminary List is currently defined as ! EUROTRANS DM1 Safety Bruxells, 17 March 2006

More Related