40 likes | 160 Views
Connection to Plant bus. PS 2: Question 6 How do the first IEC61850-based technical solution differ?. The first running substations are turnkey projects. Typical system. Example: Garzweiler II
E N D
Connection to Plant bus PS 2: Question 6How do the first IEC61850-based technical solution differ? • The first running substations are turnkey projects. Typical system Example: Garzweiler II • Station bus for three voltage levels:110kV – Section (HSA) 25/6 kV- Section (HSA) 6kV – Section (BSP) • Over 140 Protection and Bay Units.7SJ63, 7SJ64, 6MD66 and 7SJ62: IEC61850 7UT6: IEC60870-5-103 • Connection to tap-change and Petersen-coil regulator using IEC61850 • High Availability due to automatic ring management using intelligent switch modules general indications Station bus IEC61850 FO-Ring with ring management Serial Hub Connection toBay Units usingIEC61850 Connection toBay units using IEC60870-5-103 Switchgear IEC61850 - RJ45 IEC61850 – optical fiber
Control Centre Pilot project: RWE Rheinbraun – Garzweiler II – Control room remote HMI (Net Meeting) • SICAM PAS-System, consisting of: Full server 2xDIP (Device Interface Processor) SICAM PAS CC remote Control PC Mobile Control PC • Bay controller via IEC61850 IEC 60870-5-103 • Substation connection IEC60870-5-101 • Control center connection IEC 60870-5-101 • Notebook as mobile Control PC useful at every switch. local HMISICAM PASCC IEC60870-5-101 SICAM PAS FS DIP 10 km DIP Transformer monitoring 4 times IEC 101 IEC61850 bus FO-Ring with ring management Connection Station bus110kV HSA Connection Station bus6kV BSP Connection to Station bus25/6kV HSA MobileControl-PC IEC61850 - RJ45 IEC61850 – optical fiber IEC 60870-5-xxx- Cu
Pilot project: VW SalzgitterControl room local HMI SICAM PAS CC IEC61850 / IEC60870-5-103 Hall 1 IEC 61850 IEC 103/ RS485 SICAM PAS 1 … 5 Switchgear Hall 2 Connection to Corporate Network Hall 3 Hall 4 generalstation indications Central heating Ethernet TCP/IP IEC61850 / IEC60870-5-103 Station bus to production sections IEC61850 - RJ45 IEC61850 – optical fiber IEC 60870-5-103- Cu
Pilot project: VW Salzgitter- 20 kV switchgear Switchgear 20kV 3 sections with 12 feeders each Bay Units 6MD63/7SJ63 using IEC 61850 Protection Units 7SD61 using IEC 103 Due to short distances, a RS485 copper connection is used Connection to plant busapprox. 20 m Station bus IEC61850twisted-pair cable ring IEC61850 SerialHub IEC 103/ RS485 1 … 12 Switchgear Section 1 section 2 section 3 IEC61850 - RJ45 IEC61850 – optical fiber IEC 60870-5-103- Cu