Beam size measurement

Vertical SR opening angle ~ ±4.5 mrad V. λ=400nm. “Filament-Beam-Spread-Function”. Image plane. e - beam. Lens. Beam size measurement. The π -polarization method : An image of the beam is formed from vertically polarized visible-UV synchrotron radiation.

landis
Download Presentation

Beam size measurement

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Vertical SR opening angle ~ ±4.5 mradV λ=400nm “Filament-Beam-Spread-Function” Image plane e- beam Lens Beam size measurement The π-polarization method: An image of the beam is formed from vertically polarized visible-UV synchrotron radiation. A π phase shift between the two radiation lobes ==> Iy=0=0 in ”FBSF” Finite vert. beam size ==> Non-zero central intensity

  2. Beam size measurement: alternative/complement The interference method (Mitsuhashi):

  3. Beam size measurement: beamline components CRUCIAL! the ”finger” absorber

  4. Beam size measurement: precision Vertical: Predicted profiles (SRW*) for beam height values 0, 6.4, 9.0µm, and measured. Statistical rms error = 0.1µm Horizontal: Predicted profiles (SRW) for beam width values 54, 57, 60µm, and measured. Statistical rms error = 0.3µm *) Synchrotron Radiation Workshop, see EPAC’98 Chubar, Ellaume

  5. Beam size measurement: systematic errors • The smallest rms beam height values so far measured at SLS are around 5 µm. In this region it is difficult to exclude systematic error contributions to the measured value from various non-perfect optical elements. The valley-to peak ratio is only ~ 5 %, and this number we should consider as a lower limit.

  6. Principles for a new monitor • For a rms beam height of 3 µm, we can keep the valley-to-peak ratio to 6% with the same type of experimental set-up (transmission optics). The only difference is to use 200 nm SR instead of the present 365 nm. Fused Silica is transmitting well enough; a custom made interference filter might be needed (230 nm filters are available); a Glan-Taylor polarizer should still do (Calcite). • We should consider going to a reflective focussing mirror instead of a lens. This should ease the requirements on the interference filter. It could also allow for even shorter wavelengths, but then the CCD has to go into vacuum; filters and polarizer still to be found. • A central absorber with larger heigth can be introduced  allows a cross-check with the interference method (Mitsuhashi).

  7. Possible improvements on exciting monitor: • Exit window should be made of a λ/20 optical flat piece. Tests OK at MAX-lab. • The exit window can be cleaned in situ if a valve is introduced in front. It is a possible method for mirror cleaning (removing Carbon), to leak in oxygen and expose it to UV-radiation. We should be able to do likewise. • The lens can be made with better surface accuracy, λ/20, than the present. It should also have a longer focal length. • A central absorber with larger heigth can be introduced  allows a cross-check with the interference method (Mitsuhashi).

  8. Outlook, MAX-IV 3 GeV ring: π-polariz. metod E = 3 GeV C = 528 m I = 500mA ex = 250 pmrad ey = 1 pmrad βy = 14 m ==> σy=3.7μm OK! βx = 1.8 m ==> σx=21μm Large hor. acc. angle ==> OK! Light source MAX IV Observe