1 / 9

Summary of XP-710

Summary of XP-710. D. A. Gates NSTX Results review 7/24/07. Status of NHTX-like discharge development. Strong shaping achieved Achieved non-inductive fraction of 55% nearly equivalent to that in 116318 (NSTX record pulse length) H-mode achieved during current ramp at 5.5kGauss

landon
Download Presentation

Summary of XP-710

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Summary of XP-710 D. A. Gates NSTX Results review 7/24/07

  2. Status of NHTX-like discharge development • Strong shaping achieved • Achieved non-inductive fraction of 55% nearly equivalent to that in 116318 (NSTX record pulse length) • H-mode achieved during current ramp at 5.5kGauss • Lower N limits non-inductive fraction

  3. Last years equilibrium • Equilibrium parameters: • Target Achieved •  2.7 2.65 • A 1.75 1.6 • li 0.4 0.45 • N >5.5 ~4

  4. Plasma nearly matches 116318 Red 116318, Black 124058

  5. Beam absorption is poor at low current and low li • For 5.4MW applied only 3.2MW of heating • Plasma repeatedly hits beta limit

  6. High non-inductive fraction achieved Shot 124058, TRANSP A02 • Achieved 55% non-inductive current fraction (TRANSP) • Ramped linearly up to the end of the shot • Based on EFIT02 (no MSE) - MSE based reconstructions • Reconstructions with MSE had proved problematic (current hole), but are available

  7. Plasma limited by low frequency MHD mode • Large n=1 mode detected on external locked mode detector • No USXR to confirm mode structure • Thomson shows global plasma deformation • RWM

  8. Use long pulse shot from 2008 as new starting point • Very similar to previous longest shot on NSTX • Feedback on, kappa and current both higher, li lower

  9. Run plan • Goal: Improve the operating limits for this scenario • focus on varying Bt and Ip but also investigate the effect of lithium and error field suppression • 1. Use Liter at 40mg/min, (use no glow scenario if this is effective). Start with shot 129121 (long pulse post-lithium from Jon’s error field XP-). (1 shot) • 2. Increase plasma elongation in increments of 0.1 (3 -5 shots) • 3. Using elongation with optimum non-inductive current, increase toroidal field in 0.25kGauss increments up to 5.5 kGauss. Adjust pulse to avoid trips. (12 shots) • 4. Do current scan at select toroidal fields. Use optimum toroidal field, .25kGauss higher and .25 kGauss lower. Current scan from 700-900kA in 50kA steps. (12 shots) • 5. Repeat 3 and 4 with lithium recently applied, but with evaporator off. (20 shots)

More Related