Laser Beam Transport and Integration AWAKE Collaboration meeting Mikhail Martyanov Christoph Hessler CERN, EN-STI-LP Valentin Fedosseev CERN, 04-06.12.2013. Overview. Short intense laser pulse is needed for : to create a 100% ionized plasma
E N D
Laser Beam Transport and IntegrationAWAKE Collaboration meetingMikhail Martyanov ChristophHessler CERN, EN-STI-LPValentin FedosseevCERN, 04-06.12.2013
Overview • Short intense laser pulse is needed for: • to create a 100% ionized plasma • moving ionization front is a source of perturbation for proton-laser instability (micro-bunching and wake-field with a stable phase) • Plan for the Laser system: • First it is delivered to MPP Munich for plasma experiments - mid 2014 • Then it goes to CERN - end 2015 ? M.Martyanov, CERN
AWAKE Area: Zones - doors to laser room, local access control - doors with central access control - safety “shutters” with central control Access tunnel AWAKE gallery laser SAS e-gun room laser room e-gun Laser laser beam 2 connection tunnel 400mm to be drilled… p-tunnel electron beam laser beam 1 proton beam plasma chamber M.Martyanov, CERN
Overview • Laser system comprises: - laser with 2 beams (for plasma and for the e-gun) - delay line is possible in either one of these beams - optical compressor - focusing telescope - small optical compressor and 3rd harmonics generator for e-gun • Laser parameters for plasma: - energy 450 mJ - pulse duration 120 fs after compression - beam diameter 40 mm (smoothed flat-top) Only reflective optics on the way Rule of thumb (B<1): I[GW/cm2]L[cm]<36 M.Martyanov, CERN
Laser system base-line • Laser, Compressor and Telescope are in the laser room • Focusing down to 35 meters to the center of the plasma • Question is if this possible? • Back solution: Compressor and Telescope are next tomerging point in the proton tunnel • Focusing down to 25 meters to the center of the plasma • Question is if this possible? Crucial points are: • Focusability of the laser beam down to 25 or 35 meters • No detailed information on the laser system yet (beam quality) • The placement of the optical compressor and the focusing telescope has an impact on the position of the anew drilled connection tunnel • Availability of vacuum components for the compressor and telescope is under study. • 10-6Torr “easily” achievable. Pellicle or differential pumping as an option to go better M.Martyanov, CERN
Base Line: Merging point Laser + Protons Some measurements of laser room with respect to merging point Protons and laser towards plasma Merging point Thanks to integration team for pictures M.Martyanov, CERN
Horizontal connection tunnel 400mm Thanks to integration team for pictures M.Martyanov, CERN
Merging point in details • p-beam height about 1 m • HV volume (10-6Torr) can be “easily” achieved in the laser pipes • UHV volume (10-8Torr) is supposed to be in the p-beam line laser beam 500 1400 HV volume last mirror 500 1400 750 p-beam 500 10002000 M.Martyanov, CERN
Merging point in details • Distance from p-beam envelope to optical axis is 14 mm • Assuming laser beam 10 to 16 mm • Gap between beams is 6 to 9 mm • Tough but manageable • Possible issue: mirror charging and destruction laser beam gap 6 9 mm proton beam Thanks to Chiara Bracco M.Martyanov, CERN
Vacuum components M.Martyanov, CERN
Compressor and Telescope are in the laser room • Flat-top beam focusing profiles Focusing of a 430 mJ flat-top beam 35 m downstream to the middle of the plasma. At the ideal Gaussian waist Wmax= 6.84 J/cm2 and FWHM = 2.35 mm. Flat-top beam focusing has been optimized to obtain the same maximum fluencesomewhere in the plasma and equal fluence on both sides. Flat-top beam d=14 mm , f=52 m looks like a Gaussian beam and considered as an optimum. 0 m, FWHM=14mm, Wmax=0.32J/cm2 cm 35 m, FWHM=2mm, Wmax=6.6J/cm2 • 10 m - last mirror, beam size 16 mm, no peak in the middle for reasonably smooth beams, Wmax ~ 0.5J/cm2
Compressor and Telescope are at the merging point • Flat-top beam focusing profiles Focusing of a 430 mJ flat-top beam 25 m downstream to the middle of the plasma. At the ideal Gaussian waist Wmax= 6.84 J/cm2 and FWHM = 2.35 mm. Flat-top beam focusing has been optimized to obtain the same maximum fluencesomewhere in the plasma and equal fluence on both sides. Flat-top beam d=10.6 mm , f=47 m looks like a Gaussian beam and considered as an optimum. 20 m, FWHM = 1.6mm, Wmax=5.9J/cm2 25 m, FWHM = 1.9mm, Wmax=6.8J/cm2 0 m, FWHM = 10.6mm, Wmax=0.57J/cm2 cm M.Martyanov, CERN
Compressor predesign Two gold coated gratings 1700 lines/mm, 100x140 and 120x140 mm Damage threshold ~ 250 mJ/cm2 (in AWAKE less then 100 mJ/cm2) Efficiency per 1 reflection @ 800nm and 10deg deviation – 92% Gratings supplier – SPECTROGON, Sweden Acceptance: compress 160 ps to 120 fs, bandwidth 24nm, beam size 50mm Compressor fits to 1200 x 400 mm footprint, 400 mm high, 2 view-ports for alignment Max efficiency of the compressor – 70% M.Martyanov, CERN
Telescope predesign Around 3-fold mirror telescope, detuned to provide 25 meter focusing, flat geometry Concave mirror R=2400mm, incident angle 2 Convex mirror R=800mm, incident angle -3.54 in the same plane Mirrors displacement 806mm Beam size 40mm, ray focal spot size ~100m Aberrations are negligible with respect to diffraction limit (spot size ~1 mm) Telescope footprint is 1000 x 200 mm M.Martyanov, CERN
Compressor and Telescope Entire footprint is 2400 x 600 mm Convex mirror 2” Mirrors 2” Launch mirror 3” Concave mirror 3” M.Martyanov, CERN
Laser dedicated list of “Things to Do”: Laser Installation M.Martyanov, CERN
Laser dedicated list of “Things to Do”: Laser Operation M.Martyanov, CERN
Alignment of 3 beams Just started … • OTR or laser light • Imaging (lens system and CCD) • Capture and measure with photodiode or streak-camera • (coupling to a fiber or lens system) • Other techniques laser-beam p-beam BPM BPM plasma e-beam M.Martyanov, CERN
Alignment of 3 beams • 3 beams (protons, electrons and laser) have to be align in space and time • Transverse accuracy ~ 0.2mm • Angular accuracy ~ 0.2mm / 10 m = 20rad • Timing electrons-laser ~ 100fs – alignment by response? Rough alignment is needed anyway • Timing protons-laser ~ 100ps – alignment with fast photodiode and scope possible, 1pJ of light is required. Streak-camera. For robust alignment of 3 beams we need an optical signal which comes from the same screen sensitive to 3 beams (the power of laser beam can be reduced for the measurements not to damage the screen) M.Martyanov, CERN
AWAKE access modes are under discussion … Preliminary M.Martyanov, CERN
Thank you! M.Martyanov, CERN