Objective is to create a field deployable automated CO 2 and N 2 O gas trapping device

Objective is to create a field deployable automated CO 2 and N 2 O gas trapping device Trapping events occur every four hours Traps replaced after one month Components Flux Chamber Multiple Sub-chambers Desiccant Trap CO 2 Chemical Trap N 2 O Molecular Sieve Trap

larya
Download Presentation

Objective is to create a field deployable automated CO 2 and N 2 O gas trapping device

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Objective is to create a field deployable automated CO2 and N2O gas trapping device • Trapping events occur every four hours • Traps replaced after one month • Components • Flux Chamber • Multiple Sub-chambers • Desiccant Trap • CO2 Chemical Trap • N2O Molecular Sieve Trap • CO2 Molecular Sieve Trap • Rain-water Drop System

  2. Valves Manual Solenoid Pump Flow Rate: 130 mL/min

  3. Servo Mechanism Motor Fan

  4. Materials in contact with the gases must be chemically inert and gas impermeable Outer Casing and Sub-chambers White PVC – avoiding the greenhouse effect Desiccant Trap Nafion Tubing CO2 Chemical Trap 304 Stainless Steel Tubing Carbosorb CO2 and N2O Traps 304 Stainless Steel Tubing Molecular Sieve 5A Tubing PEEK

  5. Assembly Criteria – small profile, sturdy, and easy to use Airtight System Fittings and Adapters CAD Drawings Machined in the ME Shop

  6. Control of servos, solenoids, circulation fans, pumps • State machine pertaining phases of device operation • Error checking • Sensors provide information about device functionality • Allows for quick repair, operation during non critical failure • Governed by Microcontroller

  7. Programmable System on Chip (PSoC) Visual, code-free embedded design C language base Manually edit code CY3214-PSoCEvalUSB

  8. Demands of system • Operates unattended for weeks • Hours between samples • Microcontroller very demanding • The external timer • Battery decision All-Battery.com

  9. CO2 and N2O levels will be used to determine impact of farming • This will facilitate carbon credit trading on global scale • Profitable to farmers • Reduces waste • Cost of end product is low • Will promote ecologically friendly farming practices • Questions?