1 / 11

Portabilità e robustezza Qualità di spettri a T ambiente Riconoscimenti di picchi deboli

TimePix Calibration. Supervisors: Samir Arfaoui Mathieu Benoit Student: Damiano Celeste. Portabilità e robustezza Qualità di spettri a T ambiente Riconoscimenti di picchi deboli Costi contenuti Software di identificazione. Procedure. Goal : Average calibration of detectors.

laurie
Download Presentation

Portabilità e robustezza Qualità di spettri a T ambiente Riconoscimenti di picchi deboli

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. TimePix Calibration Supervisors: Samir Arfaoui Mathieu Benoit Student: Damiano Celeste Portabilità e robustezza Qualità di spettri a T ambiente Riconoscimenti di picchi deboli Costi contenuti Software di identificazione

  2. Procedure Goal: • Average calibration of detectors. • Study of the sensor uniformity and single pixel calibration. • Use energy values instead of TOT for test-beam analysis. Procedure: Sources and XRF spectra acquisitions to obtain a fit to the surrogate function. Detectors: Sources: • A06-W0110: 50μm, V=15V - 55Fe: 5.8 keV • L04-W0125: 100μm, V=35V - 109Cd: 22.9 keV • C04-W0110: 50μm, V=15V - 241Am 26.2 keV; 60 keV • D09-W0126: 300μm, V=35V X-rayfluorescence: • B06-W0125: 100μm, V=-50V - Indium: 24 kev • B07-W0125: 100μm, V=40V - Copper: 8 kev

  3. Previous tate of work Done WIP Nextsteps

  4. State of work Done WIP Nextsteps

  5. C04-W0110 RECONNECT CLOSER SAMPLE RECONNECT CLOSER SAMPLE

  6. B07-W0125 COPPER MASK COPPER MASK

  7. D09-W0126 NO MASK COPPER MASK MASK + RECONNECT COPPER MASK NO MASK MASK + RECONNECT

  8. C04-W0110: χ2

  9. Questions and next steps Questions: • Why and howdoes the reconnection of the deviceaffectmeasurements? • Whichis the best set-up for XRF flourescence? • Should we take into account the χ2 factor? How? • Does the great amount of events on the detector affect measurements? Next steps: • To try to understand what happens to DAC when reconnecting • Using a Co57 source, gamma emission around 8 keV • Once obtained good global results  Single Pixel Calibration

  10. -NO RECONNECT -MASK -CLOSER SAMPLE -NO RECONNECT -NO MASK -CLOSER SAMPLE -NO RECONNECT -MASK -CLOSER SAMPLE -NO RECONNECT -NO MASK -CLOSER SAMPLE

  11. -RECONNECT -MASK -CLOSER SAMPLE -RECONNECT -MASK -CLOSER SAMPLE