280 likes | 493 Views
Oh Crap….Now What Have Those Lochinvar Guys Done??. Raypak Laars RBI AO Smith Riverside. The “Good” Just Got “Better”!. HISTORY. Introduced in 1990; over 20 years ago. First horizontal HEX fan assisted design. First horizontal HEX low NOx design. First stackable design.
E N D
Oh Crap….Now What Have Those Lochinvar Guys Done?? Raypak Laars RBI AO Smith Riverside
HISTORY • Introduced in 1990; over 20 years ago. • First horizontal HEX fan assisted design. • First horizontal HEX low NOx design. • First stackable design. • First gasketless HEX design. • First proportional fired design. • Lochinvar was the first ACT in 1990 and we are still “Setting the Stage” in 2011…..
CopperFin ll Today • Highly copied • Heavy competition
How Do We Separate Ourselves? • Leadership • Reliability and Performance • Product Refinement / Enhancement • Unmatched Features • Lochinvar is Maintaining this Successful Strategy with yet another major product enhancement!
Copper-fin II Enhancement Models • Boiler, Water Heater and Pool Heater • Example model number, CFN402PM, CHN2072 • Copper-Fin 495-2066 series, Boiler and Water Heater will share assembly changes. Will now be 497-2067.
Copper-fin II Changes • New Look • Controls upgrade, including Smart System • Thermal Efficiency – 85% • Improved Heat Exchanger • Enhanced Combustion chamber
Copper-fin II • 4:1 Turndown – Down to 25% of Input in Stages • 2 Line, 16 Character Display – Uses Real Words, Not Codes • F or C Display • 2 Levels of Password Security – Installer & User • Inlet & Outlet Water Temperature Sensors • Outdoor Reset – Includes Sensor • Cascading “Sequencing” of 8 units • Building Management System (BMS) Control • Accepts a 0-10 Vdc Input • Night Setback • Pump Relay w/ Freeze Protection • Domestic Hot Water Prioritization (DHWP) • Low Water Flow Indication • Contacts on Any Failure • Service Mode • Product Service Indicator – Display on # of cycles, hrs. of operation or time since last service
Copper-Fin II Front-End Loading Capability or Hybrid System Efficiency Optimization with Crest as the leader Lead/Lag if Copper-Fin II is the leader Controls will recognize different product sizes based on BTU Groups
“Wiped” fins make the spacing between the tubes more compact.
The “tube sheet” spacing becomes narrower for wiped tubes. 11-1/4” ~3” Narrower The Inlet / Outlet dimension remains the same making retrofits easy. NOTE: Heat Exchangers are NOT backward compatible with old style!
Outlet Sensor Tapping Inlet Sensor Tapping
Individual Removable Panels • Easy access to Upper and Lower Chambers • Less Time Consuming Service & Preventative Maintenance
Combustible Floor Installation Shipped as “KIT” on 402 thru 752 Standard on 992 thru 2072
Coming to a Jobsite Near You! CF/CH/CP Product available September 1st CW/CB Product available June1st