BASIC PARAMETERS

BASIC PARAMETERS. At ‘reference’ orbit (10 MeV?). COMBINING DIPOLE & QUAD FIELD. from experience, combining variable dipole and quadrupole field in the same magnet is difficult and expensive;

Download Presentation

BASIC PARAMETERS

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. BASIC PARAMETERS At ‘reference’ orbit (10 MeV?) EMMA Hardware Meeting 1/7/06

  2. COMBINING DIPOLE & QUAD FIELD • from experience, combining variable dipole and quadrupole field in the same magnet is difficult and expensive; • the series of ‘allowed’ harmonics in dipoles is n = 1, 3, 5, etc; ie dipoles are quadrupoles are ‘chalk and cheese’; • the parameters given above show that the EMMA magnets are substantially quadrupole magnets with low dipole components; SOLUTION: • build the EMMA magnets as pure quadrupoles; • position them off-centre to provide the dipole component; • when the ratio dipole/quadrupole needs to be varied, adjust the quad field and move the magnets radially to retain to correct dipole field. EMMA Hardware Meeting 1/7/06

  3. MOVING MAGNETS DURING OPERATION IS NOT NEW! • In HERA (DESY), e- spin transfer into the longitudinal plane requires a horizontal and vertical bump to be applied after vertical polarisation has been achieved – • horizontal is applied first; • then the vertical bump is applied and magnet positions changed to keep beam inside the vacuum vessel. With thanks to Prof. Des Barber, DESY and U. of Liverpool. – see http://www.lancs.ac.uk/cockcroft-institute/education/Barber_spin_June06.ppt EMMA Hardware Meeting 1/7/06

  4. BEFORE AND AFTER Before vertical bump is applied. After vertical bump is applied. With thanks to Prof. Des Barber, DESY and U. of Liverpool. – see http://www.lancs.ac.uk/cockcroft-institute/education/Barber_spin_June06.ppt EMMA Hardware Meeting 1/7/06

  5. RESULTING MAGNET PARAMETERS EMMA Hardware Meeting 1/7/06

  6. ‘BF’ MAGNET FEA GEOMETRY One eighth cross section used for 2D f.e.a of BF magnet. EMMA Hardware Meeting 1/7/06

  7. ‘BF’ GRADIENT QUALITY (LINEAR STEEL) Expressed as: D(dBy/dx (x,0))/By/dx (0,0); Gradient: 10.1 T./m at J = 3.2 A/mm2; Gradient quality: + 0.25% at x = 34 mm; -0.35% at x = 39 mm; Max induction in pole root: 1.24 T. EMMA Hardware Meeting 1/7/06

  8. ‘BF’ GRADIENT QUALITY (NON-LINEAR STEEL) Identical quality to linear steel case. Gradient: 9.96 T; Hence, amplitude linearity: 98.6 %. EMMA Hardware Meeting 1/7/06

  9. RESULTING ‘BF’DESIGN EMMA Hardware Meeting 1/7/06

  10. ‘BD’ MAGNET FEA GEOMETRY One eighth cross section used for 2D f.e.a of BD magnet; half-magnet geometry and mirror plate ignored (for the moment). EMMA Hardware Meeting 1/7/06

  11. ‘BD’ GRADIENT QUALITY (LINEAR STEEL) Expressed as: D(dBy/dx (x,0))/By/dx (0,0); Gradient: 6.19 T/m at J = 3.2 A/mm2; Gradient quality: + 0.04% at x = 45 mm; -0.28% at x = 59 mm; Max induction in pole root: < 1.0 T. EMMA Hardware Meeting 1/7/06

  12. HALF ‘BD’ MAGNET WITH MIRROR PLATE EMMA Hardware Meeting 1/7/06

  13. HALF ‘BD’ GRADIENT QUALITY (LINEAR STEEL) on y = 0 axis Expressed as: D(By/dx (x,0))/By/dx (0,0);between x = 5 and x = 60; (steel at x = 0 gives singularity in dBy/dx); Gradient quality: + 0.1% at x = 55 mm; - 0.25% at x = 59 mm. EMMA Hardware Meeting 1/7/06

  14. HALF ‘BD’ GRADIENT QUALITY (LINEAR STEEL) on x = 0 axis Expressed as: D(Bx/dy (0,y))/Bx/dy (0,0); between y = 0 and y = 30; Gradient quality: + 0.03% at y = 30 mm; EMMA Hardware Meeting 1/7/06

  15. RESULTING ‘BD’ DESIGN EMMA Hardware Meeting 1/7/06

  16. CELL LAYOUT GEOMETRY NOTE MAGNET PROXIMITY EMMA Hardware Meeting 1/7/06

  17. INJECTION/EXTRACTION PATH Note injection line cutting through mirror plate on median plane EMMA Hardware Meeting 1/7/06