1 / 12

Telecom Division Kyushu Matsushita Electric CO., LTD.

“. Networking KX-TD500 with HICOM 150 (Siemens) Via iQ 5000. Telecom Division Kyushu Matsushita Electric CO., LTD. “. EXT No. plan 600 - 699. Site B. How ?. 1 x PRI 02-61000/099. 38 MB IP + 2Mb E1/ G703 laser link. Networking Overview Step 1. 1 x PRI 02-88500/599

lefty
Download Presentation

Telecom Division Kyushu Matsushita Electric CO., LTD.

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Networking KX-TD500 with HICOM 150 (Siemens) ViaiQ 5000 Telecom Division Kyushu Matsushita Electric CO., LTD.

  2. EXT No. plan 600 - 699 Site B How? 1x PRI 02-61000/099 38MB IP + 2Mb E1/ G703 laser link Networking Overview Step 1 1x PRI 02-88500/599 02-88600/699 Site A Site C 1x PRI 02-88700/49 EXT No. plan 500 - 599 2 Mb G703/E1 leased link Siemens HICOM 150 Pro Siemens HICOM 150 E EXT No. plan 700 - 749

  3. EXT No. plan 600 - 699 Networking Details Step 1 Site B 1x PRI 02-61000/099 E1 ? E&M-C MISMATCH! TE PRI ? Q.931 38MB IP + 2Mb E1/ G703 laser link 1x PRI 02-88500/599 02-88600/699 Site A PRI QSIG Master EXT No. plan 500 - 599 Siemens HICOM 150 Pro

  4. NT PRI Q.931 PRI Qsig Slave Teltrend IQ5000 EXT No. plan 600 - 699 Networking Details Step 2 Site B 1x PRI 02-61000/099 TE PRI Q.931 38MB IP + 2Mb E1/ G703 laser link 1x PRI 02-88500/599 02-88600/699 Site A PRI QSIG Master EXT No. plan 500 - 599 Siemens HICOM 150 Pro

  5. EXT No. plan 750 - 799 Site D How? 7x E1 2Mb IP 1x E1 2Mb G.703/704 Radio Link Networking Overview Step 2 EXT No. plan 600 - 699 Site B 1x PRI 02-61000/099 TE PRI Q.931 IQ5000 38MB IP + 2Mb E1/ G703 laser link 1x PRI 02-88500/599 02-88600/699 Site A Site C 1x PRI 02-88700/749 PRI QSIG Master EXT No. plan 500 - 599 2 Mb G703/E1 leased link Siemen HICOM 150 Pro Siemens HICOM 150 E EXT No. plan 700 - 749

  6. Teltrend IQ5000 TE PRI Q.931 PRI Qsig Slave NT PRI Q.931 G.703 Possible Solution 1 EXT No. plan 750 - 799 Site D 7x E1 2Mb IP 1x E1 2Mb G.703/704 Radio Link Site C 1x PRI 02-88700/749 G.703 Siemens HICOM 150 E EXT No. plan 700 - 749

  7. NT PRI Q.931 PRI Qsig Slave NT PRI Q.931 NT PRI Q.931 Possible Solution 2 EXT No. plan 750 - 799 Site D Teltrend IQ5000 TE PRI Q.931 G.703 7x E1 2Mb IP 1x E1 2Mb G.703/704 Radio Link Site C 1x PRI 02-88700/749 G.703 Siemens HICOM 150 E EXT No. plan 700 - 749

  8. NT 8x BRI Q.931 IP Ethernet VoIP TE 8x BRI Q.931 NT 8x BRI Q.931 IP Ethernet VoIP TE 8x BRI Q.931 Possible Solution 3 EXT No. plan 750 - 799 Site D Qsig on TD500 only or fieldtest 7x E1 2Mb IP 1x E1 2Mb G.703/704 Radio Link Site C 1x PRI 02-88700/749 Siemens HICOM 150 E EXT No. plan 700 - 749

  9. E1 30x E&M-C IP Ethernet VoIP E1 30x E&M-C IP Ethernet VoIP SIEMENS cannot handle E1- E&M-C ! Possible Solution 4 EXT No. plan 750 - 799 Site D 7x E1 2Mb IP 1x E1 2Mb G.703/704 Radio Link Site C 1x PRI 02-88700/749 Siemens HICOM 150 E EXT No. plan 700 - 749

  10. TIE Routing 750 - 799 750 - 799 T I E 700 - 749 700 - 749 500 - 599 500 - 599 600 - 699 600 - 699 PRI Qsig Slave NT PRI Q.931 G.703 TE PRI Q.931 Teltrend Q5000 G.703 PRI Qsig Master “Final Solution’’ EXT No. plan 750 - 799 Site D 7x E1 2Mb IP 1x E1 2Mb G.703/704 Radio Link Site C 1x PRI 02-88700/749 Siemens HICOM 150 E EXT No. plan 700 - 749

  11. Final Total Solution Overview EXT No. plan 600 - 699 EXT No. plan 750 - 799 Site B Site D TE PRI Q.931 TE PRI Q.931 IQ5000 IQ5000 1x PRI 02-61000/099 7x E1 2Mb IP 1x E1 2Mb G.703/704 Radio Link 38MB IP + 2Mb E1/ G703 laser link 1x PRI 02-88500/599 02-88600/699 Site A Site C 1x PRI 02-88700/749 EXT No. plan 500 - 599 PRI QSIG Master 2 Mb G703/E1 leased link Siemen HICOM 150 Pro EXT No. plan 700 - 749

  12. InterChange iQ 5000 Teltrend Limited (U.K) Tel: +44 1256 843311 Fax: +44 1256 840429 HTTP://www.teltrend.co.uk Email:info@teltrend.co.uk IQ 5000 System Overview PRI : 2 PRI interface PRI Protocol : Euro-ISDN(ETSI-Q931) CCITT G.703/G.704/G.706/G.732    Q.SIG/DASS2/DPNSS BRI : 8 ISDN U interface / Euro-ISDN http://www.teltrend.co.uk/products/uk_pro_interchangeiq5000.htm “

More Related