120 likes | 368 Views
“. Networking KX-TD500 with HICOM 150 (Siemens) Via iQ 5000. Telecom Division Kyushu Matsushita Electric CO., LTD. “. EXT No. plan 600 - 699. Site B. How ?. 1 x PRI 02-61000/099. 38 MB IP + 2Mb E1/ G703 laser link. Networking Overview Step 1. 1 x PRI 02-88500/599
E N D
“ Networking KX-TD500 with HICOM 150 (Siemens) ViaiQ 5000 Telecom Division Kyushu Matsushita Electric CO., LTD.
“ EXT No. plan 600 - 699 Site B How? 1x PRI 02-61000/099 38MB IP + 2Mb E1/ G703 laser link Networking Overview Step 1 1x PRI 02-88500/599 02-88600/699 Site A Site C 1x PRI 02-88700/49 EXT No. plan 500 - 599 2 Mb G703/E1 leased link Siemens HICOM 150 Pro Siemens HICOM 150 E EXT No. plan 700 - 749
“ EXT No. plan 600 - 699 Networking Details Step 1 Site B 1x PRI 02-61000/099 E1 ? E&M-C MISMATCH! TE PRI ? Q.931 38MB IP + 2Mb E1/ G703 laser link 1x PRI 02-88500/599 02-88600/699 Site A PRI QSIG Master EXT No. plan 500 - 599 Siemens HICOM 150 Pro
“ NT PRI Q.931 PRI Qsig Slave Teltrend IQ5000 EXT No. plan 600 - 699 Networking Details Step 2 Site B 1x PRI 02-61000/099 TE PRI Q.931 38MB IP + 2Mb E1/ G703 laser link 1x PRI 02-88500/599 02-88600/699 Site A PRI QSIG Master EXT No. plan 500 - 599 Siemens HICOM 150 Pro
“ EXT No. plan 750 - 799 Site D How? 7x E1 2Mb IP 1x E1 2Mb G.703/704 Radio Link Networking Overview Step 2 EXT No. plan 600 - 699 Site B 1x PRI 02-61000/099 TE PRI Q.931 IQ5000 38MB IP + 2Mb E1/ G703 laser link 1x PRI 02-88500/599 02-88600/699 Site A Site C 1x PRI 02-88700/749 PRI QSIG Master EXT No. plan 500 - 599 2 Mb G703/E1 leased link Siemen HICOM 150 Pro Siemens HICOM 150 E EXT No. plan 700 - 749
“ Teltrend IQ5000 TE PRI Q.931 PRI Qsig Slave NT PRI Q.931 G.703 Possible Solution 1 EXT No. plan 750 - 799 Site D 7x E1 2Mb IP 1x E1 2Mb G.703/704 Radio Link Site C 1x PRI 02-88700/749 G.703 Siemens HICOM 150 E EXT No. plan 700 - 749
“ NT PRI Q.931 PRI Qsig Slave NT PRI Q.931 NT PRI Q.931 Possible Solution 2 EXT No. plan 750 - 799 Site D Teltrend IQ5000 TE PRI Q.931 G.703 7x E1 2Mb IP 1x E1 2Mb G.703/704 Radio Link Site C 1x PRI 02-88700/749 G.703 Siemens HICOM 150 E EXT No. plan 700 - 749
“ NT 8x BRI Q.931 IP Ethernet VoIP TE 8x BRI Q.931 NT 8x BRI Q.931 IP Ethernet VoIP TE 8x BRI Q.931 Possible Solution 3 EXT No. plan 750 - 799 Site D Qsig on TD500 only or fieldtest 7x E1 2Mb IP 1x E1 2Mb G.703/704 Radio Link Site C 1x PRI 02-88700/749 Siemens HICOM 150 E EXT No. plan 700 - 749
“ E1 30x E&M-C IP Ethernet VoIP E1 30x E&M-C IP Ethernet VoIP SIEMENS cannot handle E1- E&M-C ! Possible Solution 4 EXT No. plan 750 - 799 Site D 7x E1 2Mb IP 1x E1 2Mb G.703/704 Radio Link Site C 1x PRI 02-88700/749 Siemens HICOM 150 E EXT No. plan 700 - 749
“ TIE Routing 750 - 799 750 - 799 T I E 700 - 749 700 - 749 500 - 599 500 - 599 600 - 699 600 - 699 PRI Qsig Slave NT PRI Q.931 G.703 TE PRI Q.931 Teltrend Q5000 G.703 PRI Qsig Master “Final Solution’’ EXT No. plan 750 - 799 Site D 7x E1 2Mb IP 1x E1 2Mb G.703/704 Radio Link Site C 1x PRI 02-88700/749 Siemens HICOM 150 E EXT No. plan 700 - 749
“ Final Total Solution Overview EXT No. plan 600 - 699 EXT No. plan 750 - 799 Site B Site D TE PRI Q.931 TE PRI Q.931 IQ5000 IQ5000 1x PRI 02-61000/099 7x E1 2Mb IP 1x E1 2Mb G.703/704 Radio Link 38MB IP + 2Mb E1/ G703 laser link 1x PRI 02-88500/599 02-88600/699 Site A Site C 1x PRI 02-88700/749 EXT No. plan 500 - 599 PRI QSIG Master 2 Mb G703/E1 leased link Siemen HICOM 150 Pro EXT No. plan 700 - 749
InterChange iQ 5000 Teltrend Limited (U.K) Tel: +44 1256 843311 Fax: +44 1256 840429 HTTP://www.teltrend.co.uk Email:info@teltrend.co.uk IQ 5000 System Overview PRI : 2 PRI interface PRI Protocol : Euro-ISDN(ETSI-Q931) CCITT G.703/G.704/G.706/G.732 Q.SIG/DASS2/DPNSS BRI : 8 ISDN U interface / Euro-ISDN http://www.teltrend.co.uk/products/uk_pro_interchangeiq5000.htm “