How do we measure how much water is in a stream?. Volumetric measurements- Work on very low flows, collect a known volume of water for a known period of time Volume/time is discharge or Q Cross-section/velocity measurements Dilution gaging with salt or dye Artificial controls like weirs

Download Presentation

How do we measure how much water is in a stream?

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. How do we measure how much water is in a stream? • Volumetric measurements- • Work on very low flows, collect a known volume of water for a known period of time Volume/time is discharge or Q • Cross-section/velocity measurements • Dilution gaging with salt or dye • Artificial controls like weirs • Empirical equations, e.g. Manning’s eqn.

  2. Site factors for gaging 1. stable control - bedrock, non-erosive channel, man-made structure 2. locate gage a short distance above control 3. want minimal backwater or tidal influence 4. straight reach above gage for 4-5 channel widths 5. No local inflows or outflows- groundwater or flood bypasses 6. must be accessible at all times 7. securely mounted structure 8. stable confining banks 9. good to have a benchmark nearby for datum 10. good to have an auxillary stage nearby- staff gage

  3. Other considerations • Few eddies or areas of zero velocity • Few instream obstacles • Relatively consistent cross-section profile • Velocity and depth do not exceed instrument capabilities or personnel height

  4. Velocity – Area Method of discharge measurement By measuring the cross-sectional area of the stream and the Average stream velocity, you can compute discharge Q = VA units are L3/t (volume / time) Where Q is discharge V is velocity A is cross-sectional area

  5. Pygmy Meter Rotations make clicking sound in headphones If current strong may need weight U Mass, Boston

  6. Velocity Profile 0.2 0.6 depth 0.8 If stream is deep, take average of measurements at 0.2 and 0.8 U Mass, Boston

  7. Velocity Distribution In A Channel Depth-averaged velocity is above the bed at about 0.4 times the depth

  8. Photo from Black Hills State University

  9. How many subsections? • Subsections should be at least 0.3 feet or ~0.1 m wide • Each subsection should have 10% or less of total discharge • Number of subsections should be doable in a reasonable amount of time

  10. Velocity – Area method of discharge measurement Tape measure- horizontal location of measures taken from tape Water surface Measurement represents mid-section of a polygon Velocity measured 0.6d from water surface (0.4d from bottom) Record x value (tape distance), y value (total depth at measurement site, and velocity at 0.6d

  11. Mid-point method of calculating discharge (Q) Location of depth and velocity measurements Area included Area not included Key Assumption: Over estimation (area included) = Under estimation (area not included), therefore cross-section area is simply the sum of all the sections (rectangles), which is much easier than taking the integral! However, the hypotenuse of each over-under estimation triangle can be used to calculate the wetted perimeter.

  12. Equation for computing subsection discharge - qi Equation for computing q in each subsection X = distance of each velocity point along tape Y = depth of flow where velocity is measured V = velocity Q = total discharge = sum of qis

  13. Float method of discharge measurement • Gives good estimates when no equipment is available • Use something that floats that you can retrieve or is biodegradable if you can’t retrieve it • E.g. oranges, dried orange peels, tennis balls

  14. Float method of velocity measurement Three people are needed to run the float test. One should be positioned upstream and the other downstream a known distance apart, one in the middle to record data. The upstream person releases the f loat and starts the clock and the downstream person catches the float and signals to stop the clock. The recorder writes down the time of travel of the float. Velocity is the distance traveled divided by the time it takes to travel that distance. You should conduct at least 3 float tests and take an average velocity. With an estimate of cross-sectional area, discharge can be computed as Q = VA where V is average velocity U Mass, Boston

  15. Float Method surface velocity = distance / time average velocity = (0.8*surface velocity) U Mass, Boston

  16. Float method in action U Mass, Boston

  17. Dilution gaging method • Use a chemical tracer, dye or salt • Exotic to stream • Stable • Non-toxic • Cheap • Detectable • Do mass balance on concentrations upstream and downstream

  18. Constant injection method • Inject at known rate for some time period • Do mass balance • CTQT = CTd (Q + QT) • CT is concentration of tracer upstream • QT rate of input of tracer upstream • CTd is equilibrium concentration of tracer downstream • Q = QT(CT - CTd ) CTd

  19. How else might we estimate streamflow? Stream Stage- elevation The stage of a stream is the elevation of the water surface above a datum. The most commonly used datum is mean sea level. Gages are used to measure the stage of streams. Types of gages: - recording - non-recording U Mass, Boston

  20. Fixed Gauging Stations - Weirs Stable cross section with simple geometry rating curve – just measure stage U Mass Boston

  21. How do we measure the stage? Nonrecording gauges Staff Gauge Estimating Peak Flow Debris Line Crest Gauges - Cork U Mass, Boston

  22. Continuous Measurement - Water Level Recorders U Mass, Boston

  23. The Stage of a Stream Float moves up / down with water surface U Mass, Boston

  24. How can we relate stage to discharge? Rating Curve – relates stage to discharge Empirical relationship from observations Measure discharge at different flows USGS Rating curves usually have a break point, which is around the stage at which the river spreads out of it's banks, or it could be at a lower stage if the river bed cross section changes dramatically. Above that stage, the river does not rise as fast, given that other conditions remain constant. This is illustrated by a change in slope in the rating curve. On this figure the break point appears to be around 6-7 feet.

  25. Rating curve We can do this is Excel Very often it is a power equation (log-log) Fit a mathematical equation U Mass, Boston

  26. Resistance Equations • Manning’s Equation Equation 7.2

  27. Manning’s Equation • In 1889 Irish Engineer, Robert Manning presented the formula: Equation 7.2 • v is the flow velocity (ft/s) • n is known as Manning’s n and is a coefficient of roughness • R is the hydraulic radius (a/P) where P is the wetted perimeter (ft) • S is the channel bed slope as a fraction • 1.49 is a unit conversion factor. Approximated as 1.5 in the book. Use 1.0 if SI (metric) units are used.

  28. Discharge from Manning’s equation • Q = vA equation 7.1 • v =(1.5/n) R2/3 S1/2 (equation 7.2) • R= A/P, hydraulic radius (equation 7.3) • A = width x depth • P= wetted perimeter • S = water slope (ft/ft) • N = Manning’s roughness coefficient

  29. Parameters for Manning’s equation Water surface Cross sectional area = A Wetted perimeter = p area of stream in contact with bottom and sides R = hydraulic radius = A/p

  30. Mid-point method of calculating discharge (Q) Location of depth and velocity measurements Area included Area not included Key Assumption: Over estimation (area included) = Under estimation (area not included), therefore cross-section area is simply the sum of all the sections (rectangles), which is much easier than taking the integral! However, the hypotenuse of each over-under estimation triangle can be used to calculate the wetted perimeter.

  31. Table 7.1 Manning’s n Roughness Coefficient

  32. http://manningsn.sdsu.edu/barnes013_24.html

  33. Mountain Stream- Bottom with cobbles and large boulders http://manningsn.sdsu.edu/barnes101_41.html

  34. Plains stream- full stage, no rifts or deep pools http://manningsn.sdsu.edu/barnes020_27.html

  35. Table 7.2. Values for the computation of the roughness coefficient (Chow, 1959) n = (n0 + n1 + n2 + n3 + n4 ) m5Equation 7.12