1 / 25

SENIS 3-Axis Digital Teslameter

SENIS 3-Axis Digital Teslameter. SENIS GmbH Technoparkstrasse 1 CH-8005 Zurich www.senis.ch. SENIS. Digital Module. Cable CaH. Connector CoH. Computer. RS 232. Hall Probe. 0.129 T. Voltmeter. Module H. Module E. Output Cable. +/- 12V. Module H. Module E. Power Supply.

les
Download Presentation

SENIS 3-Axis Digital Teslameter

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. SENIS 3-Axis Digital Teslameter SENIS GmbH Technoparkstrasse 1 CH-8005 Zurich www.senis.ch SENIS

  2. Digital Module Cable CaH Connector CoH Computer RS 232 Hall Probe 0.129 T Voltmeter Module H Module E Output Cable +/- 12V Module H Module E Power Supply Structure of a Teslameter

  3. CaH X 4.0 Z 1.0 Thin wires 2.0 14.5 50 2.0 < 2 1.1 Z 1.0 14.5 50 mm Y All measures are in millimeters (mm). Module H: Hall Probe 5

  4. Probe with a window • Visible sensitive point • High-accuracy positioning • High-accuracy mapping of magnetic fields

  5. Hall Probe Package C-H3A • Position accuracy of the field sensitive volume: +/- 0.1 mm • Angular accuracy of the axes: +/- 0.5° to the surface.

  6. Type T-H3A Hall Probe

  7. Thin wires 3 4 0.64 2mm FSV 50 12mm 5 < 2 0.55 mm 2 12 X Z Z Y 3000um Z 150um X 150um 20um 150um 640um Y 550um 150um Type T-H3A Hall Probe 50

  8. Bonding connections Driving part Sensing part Front-end electronics Read-out electronics and buffers 200µm Integrated 3-Axes Hall Probe Chip Dimensions: 4300 µm x 640 µm x 550 µm

  9. Integrated Planar Hall Element • Sensitive to perpendicular • field component B • CMOS Technology: • N-Well • Depletion Layer • Isolation

  10. Integrated Vertical Hall Element • Sensitive to in-plane • field component B • CMOS Technology: • N-Well • Depletion Layer • Isolation

  11. B Bn Bp I α 2 I B sin2α Vp ∞ Planar Hall Effect

  12. ΔR R ΔR R I R R B 2 “Voff” ≡ B ∞ Vp MR long. MR trans. MR Model of the Planar Hall effect

  13. 1 2 VH1 = VH2 Reducing Offset: Orthogonal Coupling of Hall Elements 2I0 Vout = VH

  14. Reducing Offset and 1/f Noise « Switched Hall » or « Spinning Current » Technique

  15. Block diagram of the integrated Hall probe

  16. Digital Module Computer RS 232 0.129 T Module H Module E Structure of a Teslameter

  17. E-Module: inside Temp.Comp of Sens. Offset Comp. Nonlinearity Comp. Hall probe Sensitivity adjust Temperature conditioning

  18. Analogue Signal Treatment Module H Module E Temp. Comp. of SENSITIVITY VINPOS Cs (T) * X VINNEG Pr_Z SENSITIVITY Adjust. Pr_Y 3D IC Hall Probe X Out_X+ Pr_X Input Amplifier Output Amplifier Pr_T Out_X- 2.5V Cnl (B)*X3 Output Conditioning -2.5V OFFSET Comp. (20 °C) NONLINEARITY Comp. Vpt VINPOS Ct *(T-293K) Dif. Amp. xCt invertor +/- Ct *(T-293K) Vpt(20°C) VINNEG Temp. Comp. of OFFSET

  19. Cancellation of Residual Offset (1) Vx Voff_20 + Ct *(T-293K) Voff_20 Ct *(T-293K) Voff_Out T B = 0 20°C - Ct *(T-293K) (From Temperature Sensor)

  20. Vx + Voff_20 + Ct *(T-293K) B = 0 Vx + Ct *(T-293K) Pr_Z Pr_Y Vx 3D IC Hall Probe X Pr_X Input Amplifier Pr_T 2.5V -2.5V OFFSET Comp. (20 °C) Vpt VINPOS Ct *(T-293K) Dif. Amp. xCt invertor - Ct *(T-293K) Vpt(20°C) VINNEG Temp. Comp. of OFFSET Cancellation of Residual Offset (2): Block Diagram

  21. Analogue Teslameter Specifications • Full scale (nominal) ± 2 T • Output voltages differential • Sensitivity to d.c. magnetic field 5 V/T (0.5mV/G) • Tolerances of sensitivity (B = 1T d.c ) < ± 0.1 % • Temp. coefficient of sensitivity < 100 ppm /°C • Non-linearity of output (B <= 2T) < 0.05 % • Planar Hall effect: Vplan / Vvert (B = 1T) < 0.01% • Long-term instability of sensitivity < 1 % over 10 years • Offset (B = 0T) < ± 1 mV (0.2mT) • Temp. coefficient of offset < (0.02mT/°C) • Temperature out: [T(°C)-(23°C ±0.5°C)]x500mV/°C

  22. Digital Module Computer RS 232 0.129 T Module H Module E Structure of a Teslameter

  23. Digital Module: Functions • 16 bit A/D Conversions of signals from E-Module • Calibration accuracy: up to 0.01% • Digital display of Bx, By, Bz • Fast RS232 interface(115200bps)

  24. Teslameter - User Interface Digital Module Computer Load/Save calibration data Measurement Mode Graph setup Plot Measurement data on screen Serial interface

  25. SENIS GmbH Technoparkstrasse 1 CH-8005 Zurich www.senis.ch

More Related