1 / 13

TIA-1083 Wireline Telephone HAC Performance Requirements

TIA-1083 Wireline Telephone HAC Performance Requirements. With a Comparison to C-63.19 Wireless Telephone HAC Magnetic Performance Requirements. ANSI/TIA-1083-2007. Telecommunications – Telephone Terminal Equipment – Handset Magnetic Measurement Procedures and Performance Requirements

lev-joyce
Download Presentation

TIA-1083 Wireline Telephone HAC Performance Requirements

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. TIA-1083 Wireline TelephoneHAC Performance Requirements With a Comparison toC-63.19 Wireless TelephoneHAC Magnetic Performance Requirements

  2. ANSI/TIA-1083-2007 • Telecommunications – Telephone Terminal Equipment – Handset Magnetic Measurement Procedures and Performance Requirements • Approved March 21, 2007 • Developed by TIA TR-41.3, Analog and Digital Wireline Terminals

  3. Overview • Addresses magnetic interference issues identified by hearing aid users. • RF interference does not appear to be a significant issue for cordless telephones.

  4. Requirements Summary • Signal Sensitivity: •  -22 dB (A/m) at 1000 Hz, Perpendicular •  -27 dB (A/m) at 1000 Hz, Transverse • Same as Part 68, but greater latitude allowed in measurement location. • Harmonic Distortion: •  10%, Perpendicular and Transverse • Frequency Response: • Same as Part 68 and C63.19, Perpendicular.

  5. Requirements Summary (cont) • A-Weighted Noise: •  -40 dB (A/m), Perpendicular and Transverse • Measured same as in C63.19 using half-band integrator. • Signal-to-Noise Ratio: •  45 dB, Perpendicular and Transverse • Approximately equivalent to 30 dB requirement for C63.19.

  6. Requirements Summary (cont) • Signal-to-Noise Ratio (cont) • Noise is measured same way for both standards. • Signal in C63.19 represents “nominal level speech input” (see Footnote 45). • Signal in TIA-1083 is same as in Part 68 and is “approximately 15 dB above the average level” (see paragraph 2.4 in EIA RS-504 as reproduced in 47 CFR 68.316).

  7. Perpendicular Measurement

  8. Transverse Measurement

  9. 2005 SHHH Cordless Study Figure C.3 from TIA-1083

  10. 2006 HLAA Parametric Study Figure D.3 from TIA-1083

  11. RF Interference ?? • Informal FCC Complaints received by cordless telephone manufacturers were from T-coil users. • RF power level typically 200 mW. • 2005 SHHH Cordless Study included 27 people who used T-coil coupling and 5 who used acoustic coupling to the microphone.

  12. 2005 SHHH Cordless Study

  13. Contact Information Stephen R WhitesellTIA Representative to C63Chair, TIA TR-41Senior Technical ConsultantStandards, Regulatory and Intellectual Property MattersVTech CommunicationsTel: 732 751 1079Email: swhitesell@vtech.ca

More Related