1 / 8

Excess Ion Heating and Diagnostic Requirements

Excess Ion Heating and Diagnostic Requirements. Patrick Ross Energetic Particles Science Focus Group Meeting September 9, 2008. Outline. Background Power Balance Excess Ion Heating in NSTX Excess Heating correlates with hgih frequency fast ion MHD NPA view of Fast Particles

liko
Download Presentation

Excess Ion Heating and Diagnostic Requirements

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Excess Ion Heating and Diagnostic Requirements Patrick Ross Energetic Particles Science Focus Group Meeting September 9, 2008

  2. Outline • Background • Power Balance • Excess Ion Heating in NSTX • Excess Heating correlates with hgih frequency fast ion MHD • NPA view of Fast Particles • Additional Measurement Needs

  3. Background-Power Balance • Assuming no excess heating and only neoclassical heat transport: Pbi QNC Qie • If there is excess heating, it can be calculated by: Using Transp we can calculate the power balance terms for the discharge to check for excess heating

  4. Excess Ion Heating has been Observed Transp calculated ion power balanced shows that extra heating is required to satisfy the power balance. The total power ‘loss’ in the top graph is the blue curve, while the total heating is the red curve. The bottom plot, shows the total extra heating required.

  5. Heating Scales with Mode Amplitude, Similar to Prediction Reproduced from Gates, et al., Phys. Rev. Lett., 87, 205003 (2001). Stochastic heating has been theorized as a result of high frequency, fast particle drive, MHD modes. The calculated excess heating required shows the same form as the stochastic heating of the thermal ions.

  6. Excess Heating Peaks Near where Alfvén Modes Peak Radial Profiles of CAE modes High frequency Alfvén modes (black: radial mode=0; red: radial mode=1) Excess heating as calculated by Transp. (Top is heating density, bottom is total heating) The required excess heating peaks around 134 cm, which is near the peak amplitude of the high frequency Alfvén modes. It is not yet clear if the modes might be responsible for the excess heating.

  7. NPA Does Not Show Full Fast Ion Distribution The Neutral Particle Analyzer shows particles at a given pitch angle. However, if energy from fast particles lose energy preferentially (E┴ ), then that would effectively be pitch angle scattering, and might “scatter” particles out of the NPA view. Saturation has occurred at full energy, but ONLY that channel shows significant particle density. Where did the fast ions go?

  8. Additional Measurement Needs : • Measurements of n(v║/v,r) to see spatial diffusion • This should be solved by FIDA • Measurements of n(E,pitch) to see pitch angle scattering • This would require significant upgrades to the NPA • Many channels of energy resolved data looking at the same location • Also should improve the way TRANSP handles NPA • Guiding center approximation not sufficient • Full geometry, including position of NPA relative to beams my be necessary

More Related