1 / 5

12-Channel Electrocardiograph

Abimed 12-Channel Electrocardiograph simultaneously captures 12-lead ECG signals and prints them using high-resolution thermal technology. Its user-friendly touchscreen ensures seamless operation, with a measurement range of 1 to 5 mVp-p and a frequency response of 0.05Hz to 150Hz (-3dB to 4dB). Additionally, the device's large memory stores over 1,000 cases for easy access.

lindahaley
Download Presentation

12-Channel Electrocardiograph

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. 12-Channel Electrocardiograph AM- EGA11

  2. www.abimed.com | info@abimed.com

  3. Overview 12-Channel Electrocardiograph AM-EGA11 enables the medical professionals to collect 12-lead ECG signals simultaneously and print the ECG waveform using thermal printing technology. The high resolution touch-screen allows easy and smooth operation. Large memory storage makes it convenient to store the data of the patient and access it in the future. Specifications : Acquisition Mode Simultaneous 12 leads acquisition Measurement Range 1 ~ 5 mVp-p Time Constant ≥ 3.2s Frequency Response 0.05Hz ~ 150 Hz (-3dB ~ +4dB) Sensitivity 2.5, 5, 10, 20, 40 mm/mV; ±5% Input Impedance ≥ 50 MΩ Noise Level < 15 µVp-p Anti-baseline Drift Automatic Patient Current Leakage < 10 µA CMRR >100dB EMG interference filter: 25Hz/35Hz (-3dB) Filter Power frequency filter: AC 50Hz/60Hz(-20dB)) Recording Method Thermal Printing Recording Paper Dimension 80 mm x 20 m

  4. Auto: 5, 6.25, 10, 12.5, 25, 50, 100 mm/s; ± 5 % Paper Speed Rhythm: 5, 6.25, 10, 12.5, 25, 50, 100 mm/s; ± 5% Class I, type CF and defibrillation-proof applied part Safety Standard Input Circuit Floating and defibrillation protection Sample Rate 1000 Hz AC: 100V ~ 240V, 50 / 60Hz, 30VA ~ 100VA Power Supply DC: 14.8V / 2200mAh, built-in lithium battery Unit Dimension 410 x 300 x 200 mm Unit Weight 4 kg Features : -High-resolution thermal printing system -Real-time and continuous recording of accurate ECG waveform -“Leadoff” and “Lack of paper” indication -Time print can be set to every 1/2/3/5/10/20/30/60 minutes -Can store more than 1000 cases -Multi-language interface and report Standard Accessories : Lead cable Limb electrodes Chest electrodes

  5. Thermal recording paper A power cord Applications : It is mainly used by health professionals in hospitals and Research centers to detect the Atrial fibrillation, bradycardia, tachycardia, normal heart rhythm and certain arrhythmias that are the leading indicators of cardiovascular diseases. Abimed Inc USA. Email: info@abimed.com | Website: www.abimed.com